wdmCtrlChannelStartupCommand

LUM-WDM-MIB · .1.3.6.1.4.1.8708.2.4.2.8.1.1.19

Object

column LUM-TCCommandString
Initiates a safe startup sequence for the
channel. If the administrative status of the channel
is 'down' or the channel is not detected by the
monitor unit, the system attempts to detect the
channel as follows:
              
1) The attenuation is set to its maximum value.
              
2) The attenuation is decreased until the channel is
detected by the monitor.
              
When the channel is detected, regulation of the
channel is started, ignoring the regulation range.
              
If the channel cannot be detected, channelStatus is
set to notFound. If regulation fails, channelStatus
is set to 'error' and an alarm is raised.
              
When the startup sequence is finished, the
administrative status of the channel is set to 'up'.
              
If a regulation is ongoing when the startup
procedure is initiated, the channel is put on a
waiting queue until the ongoing regulation is
finished. The startup queue has a limited length. If
the queue is filled up with waiting channels,
further startup commands will be blocked until all
the queued channels have been started.

Context

MIB
LUM-WDM-MIB
OID
.1.3.6.1.4.1.8708.2.4.2.8.1.1.19
Type
column
Access
readonly
Status
current
Parent
wdmCtrlChannelEntry
Table
wdmCtrlChannelTable
Siblings
27

Syntax

LUM-TCCommandString
Source
LUM-TCCommandString
Base type
OctetString

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects