juniSystemRedundancyRevertControl

Juniper-System-MIB · .1.3.6.1.4.1.4874.2.2.2.1.1.17

Object

scalar r/w Enumeration
Global control for reverting primary modules back from their active
redundant spare modules:
    off       - Disable global reverts of redundant modules.
    immediate - All redundant module pairs are to revert as soon as the
                primary module is ready to enter the online state.
    timeOfDay - All redundant module pairs are to revert at the time
                specified by juniSystemRevertTimeOfDay, relative to
                midnight based on the system clock time.  This object
                must be set concurrently with juniSystemRevertTimeOfDay
                when this value is specified.
          
Note that this only applies to modules that have
juniSystemModuleRedundancySupport set to true(1).

Context

MIB
Juniper-System-MIB
OID
.1.3.6.1.4.1.4874.2.2.2.1.1.17
Type
scalar
Access
readwrite
Status
current
Parent
juniSystemGeneral
Siblings
27

Syntax

Enumeration

Values & Constraints

Enumerated Values
0off
1immediate
2timeOfDay

Related Objects