juniSystemHighMemUtilThreshold

Juniper-System-MIB · .1.3.6.1.4.1.4874.2.2.2.1.1.5

Object

scalar r/w percent Integer32
The value of memory utilization in the primary system processor, where,
if reached for the first time after a high memory threshold reset, a
high memory utilization event notification will be sent to the
management entity on this system.  A high memory threshold reset occurs
when the system is initialized (booted) or the memory utilization falls
below the value in juniSystemAbatedMemUtilThreshold.
          
The value of this object must always be greater than the value of
juniSystemAbatedMemUtilThreshold.

Context

MIB
Juniper-System-MIB
OID
.1.3.6.1.4.1.4874.2.2.2.1.1.5
Type
scalar
Access
readwrite
Status
current
Units
percent
Parent
juniSystemGeneral
Siblings
27

Syntax

percent Integer32

Values & Constraints

Object Constraints
range: 1-99

Related Objects

Sibling Objects