icfVgPortStatus

ICF-VG-RPTR · .1.3.6.1.4.1.11.2.14.8.1.1.3.1.1.5

Object

column Enumeration
Current status for the port as specified by the
PORT_META_STATE in the port process module of clause
12 [IEEE Draft Std 802.12].
              
During initialization or any link warning conditions,
icfVgPortStatus will be 'inactive(2)'.
              
When Training_Up is received by the repeater on a
local port (or when Training_Down is received on
a cascade port), icfVgPortStatus will change to
'training(3)' and icfVgTrainingResult can be
monitored to see the detailed status regarding
training.
              
When 24 consecutive good FCS packets are received and
the configuration bits are OK, icfVgPortStatus will
change to 'active(1)'.
              
A disabled port shall have a port status of
'inactive(2)'.

Context

MIB
ICF-VG-RPTR
OID
.1.3.6.1.4.1.11.2.14.8.1.1.3.1.1.5
Type
column
Access
readonly
Status
current
Parent
icfVgBasicPortEntry
Table
icfVgBasicPortTable
Siblings
11

Syntax

Enumeration

Values & Constraints

Enumerated Values
1active
2inactive
3training

Related Objects

Sibling Objects