RLE-FALCON-EM-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
25
Rows
25
Columns
125

falconKeypadUsersTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.2.2.2 · 1 row entry · 3 columns
A table of the falcon keypad users.  The number of
users is given by the value of falconKeypadUsers.
falconKeypadUserEntry entry .1.3.6.1.4.1.3184.1.5.1.2.2.2.1
An entry containing objects for the Falcon
keypad user configuration.
Indexes
falconKeypadUserIndex
Column Syntax OID
falconKeypadUserIndex mandatory
A unique value for each keypad user. Its value
ranges between 1 and the value of falconKeypadUsers.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.2.2.2.1.1
falconKeypadCode mandatory
The falcon keypad access code for user #X.
This can be up to six numeric characters.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.2.2.2.1.2
falconKeypadName mandatory
The falcon keypad access name for user #X.
This can be up to 20 characters.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.2.2.2.1.3

falconInputTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.3.1.2 · 1 row entry · 16 columns
A table of the falcon input port status and configuration.
The number of input ports is given by the value of 
falconNumberOfInputPorts.
falconInputEntry entry .1.3.6.1.4.1.3184.1.5.1.3.1.2.1
An entry containing objects for the Falcon
input port data and configuration.
Indexes
falconInputIndex
Column Syntax OID
falconInputIndex mandatory
A unique value for each input port. Its value
ranges between 1 and the value of falconNumberOfInputPorts.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.3.1.2.1.1
falconInputType mandatory
The installed hardware for Input Number X. If this value
is notInstalled(0) then this input is not physically installed
in the falcon.
Enumeration
Enumerated Values:
0notInstalled
1analog
2digital
.1.3.6.1.4.1.3184.1.5.1.3.1.2.1.2
falconInputState mandatory
The state of use of Input Number X. When a sensor is
connected to Input 1 set State to installed(2) to
indicate that the value of falconReading1 is valid.
When no sensor is connected to Input 1 set
State to notConfigure…
Enumerationr/w
Enumerated Values:
0notInstalled
1notConfigured
2analog4to20Installed
3digitalNOInstalled
4digitalNCInstalled
5digitalSTInstalled
.1.3.6.1.4.1.3184.1.5.1.3.1.2.1.3
falconInputReading mandatory
The reading for sensor.
If the input is digital, the reading will be 1 (active) or
0 (inactive)
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.1.2.1.4
falconInputGain mandatory
A correction gain associated with the sensor variable.
The value of gain is multiplied by the value from
Input Sensor to obtain the value of the Input variable.
Integer32r/w
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.1.2.1.5
falconInputOffset mandatory
A correction Offset associated with the sensor variable.
The value of Offset is added to the value from
the Input Sensor to obtain the value of the Input variable.
Integer32r/w
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.1.2.1.6
falconInputLabel mandatory
A user-defined text string associated with the Input port.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.3.1.2.1.7
falconInputUOM mandatory
A user-defined text string associated with the Input port.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.3.1.2.1.8
falconInputHighLimit2 mandatory
When the input port reaches or exceeds this value a trap will
be generated signifying a high alarm condition at this sensor.
Integer32r/w
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.1.2.1.9
falconInputHighLimit mandatory
When the input port reaches or exceeds this value a trap will
be generated signifying a high alarm condition at this sensor.
Integer32r/w
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.1.2.1.10
falconInputLowLimit mandatory
When the input port reaches or goes below this value a trap will
be generated signifying a low alarm condition at this sensor.
Integer32r/w
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.1.2.1.11
falconInputLowLimit2 mandatory
When the input port reaches or goes below this value a trap will
be generated signifying a low alarm condition at this sensor.
Integer32r/w
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.1.2.1.12
falconInputDelay mandatory
The number of seconds an alarm for this input must
be present before annunication. The range of this
setting is 0..600.
Integer32r/w
Constraints:
range: 0-600
.1.3.6.1.4.1.3184.1.5.1.3.1.2.1.13
falconInputHysteresis mandatory
The value of alarm hysteresis for this input.
The input reading must decrease or increase by this
value before the alarm will clear.
Integer32r/w
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.1.2.1.14
falconInputSchedule mandatory
The current alarm disable schedule for the input port.
Enumeration
Enumerated Values:
0none
1a
2b
.1.3.6.1.4.1.3184.1.5.1.3.1.2.1.15
falconInputDigOffLabel mandatory
A user-defined text string associated with the input port.
This string is used for digital off text.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.3.1.2.1.16

falconTSTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.3.2.1.2 · 1 row entry · 13 columns
A table of the falcon internal temperature sensor
status and configuration. The number of sensors is given
by the value of falconNumberOfTempSensors.
falconTSEntry entry .1.3.6.1.4.1.3184.1.5.1.3.2.1.2.1
An entry containing objects for the Falcon internal
temperature sensor data and configuration.
Indexes
falconTSIndex
Column Syntax OID
falconTSIndex mandatory
A unique value for each internal temperature sensor. Its value
ranges between 1 and the value of falconNumberOfTempSensors.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.3.2.1.2.1.1
falconTemperatureSensorState mandatory
The state of use of the internal temperature sensor.
Enumerationr/w
Enumerated Values:
0degF
1degC
.1.3.6.1.4.1.3184.1.5.1.3.2.1.2.1.2
falconTemperatureSensorReading mandatory
The reading for internal temperature sensor.
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.2.1.2.1.3
falconTemperatureSensorOffset mandatory
A correction Offset associated with the sensor variable.
The value of Offset is added to the value from
internal temperature sensor to obtain the value of
the TemperatureSensor variable.
Integer32r/w
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.2.1.2.1.4
falconTemperatureSensorLabel mandatory
A user-defined text string associated with internal temperature sensor.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.3.2.1.2.1.5
falconTemperatureSensorUOM mandatory
A user-defined text string associated with internal temperature sensor.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.3.2.1.2.1.6
falconTemperatureSensorHighLimit2 mandatory
When the internal temperature sensor reaches or exceeds this value a trap will
be generated signifying a high alarm condition.
Integer32r/w
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.2.1.2.1.7
falconTemperatureSensorHighLimit mandatory
When the internal temperature sensor reaches or exceeds this value a trap will
be generated signifying a high alarm condition.
Integer32r/w
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.2.1.2.1.8
falconTemperatureSensorLowLimit mandatory
When the internal temperature sensor reaches or goes below this value a trap will
be generated signifying a low alarm condition.
Integer32r/w
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.2.1.2.1.9
falconTemperatureSensorLowLimit2 mandatory
When the internal temperature sensor reaches or goes below this value a trap will
be generated signifying a low alarm condition.
Integer32r/w
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.2.1.2.1.10
falconTemperatureSensorDelay mandatory
The number of seconds an alarm for this input must
be present before annunication. The range of this
setting is 0..600.
Integer32r/w
Constraints:
range: 0-600
.1.3.6.1.4.1.3184.1.5.1.3.2.1.2.1.11
falconTemperatureSensorHysteresis mandatory
The value of alarm hysteresis for this sensor.
The reading must decrease or increase by this
value before the alarm will clear.
Integer32r/w
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.2.1.2.1.12
falconTemperatureSensorSchedule mandatory
The current alarm disable schedule for this sensor.
Enumeration
Enumerated Values:
0none
1a
2b
.1.3.6.1.4.1.3184.1.5.1.3.2.1.2.1.13

falconHSTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.3.2.2.2 · 1 row entry · 12 columns
A table of the falcon internal humidity sensor
status and configuration. The number of sensors is given
by the value of falconNumberOfHumiditySensors.
falconHSEntry entry .1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1
An entry containing objects for the Falcon internal
humidity sensor data and configuration.
Indexes
falconHSIndex
Column Syntax OID
falconHSIndex mandatory
A unique value for each internal humidity sensor. Its value
ranges between 1 and the value of falconNumberOfHumiditySensors.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.1
falconHumiditySensorReading mandatory
The reading for internal humidity sensor.
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.3
falconHumiditySensorOffset mandatory
A correction Offset associated with the sensor variable.
The value of Offset is added to the value from
internal humidity sensor to obtain the value of
the HumiditySensor variable.
Integer32r/w
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.4
falconHumiditySensorLabel mandatory
A user-defined text string associated with internal humidity sensor.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.5
falconHumiditySensorUOM mandatory
A user-defined text string associated with internal humidity sensor.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.6
falconHumiditySensorHighLimit2 mandatory
When the internal humidity sensor reaches or exceeds this value a trap will
be generated signifying a high alarm condition.
Integer32r/w
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.7
falconHumiditySensorHighLimit mandatory
When the internal humidity sensor reaches or exceeds this value a trap will
be generated signifying a high alarm condition.
Integer32r/w
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.8
falconHumiditySensorLowLimit mandatory
When the internal humidity sensor reaches or goes below this value a trap will
be generated signifying a low alarm condition.
Integer32r/w
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.9
falconHumiditySensorLowLimit2 mandatory
When the internal humidity sensor reaches or goes below this value a trap will
be generated signifying a low alarm condition.
Integer32r/w
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.10
falconHumiditySensorDelay mandatory
The number of seconds an alarm for this sensor must
be present before annunication. The range of this
setting is 0..600.
Integer32r/w
Constraints:
range: 0-600
.1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.11
falconHumiditySensorHysteresis mandatory
The value of alarm hysteresis for this sensor.
The sensor reading must decrease or increase by this
value before the alarm will clear.
Integer32r/w
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.12
falconHumiditySensorSchedule mandatory
The current alarm disable schedule for the humidity sensor.
Enumeration
Enumerated Values:
0none
1a
2b
.1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.13

falconRelayTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.4.1.2 · 1 row entry · 6 columns
A table of the falcon output relay status and configuration.
The number of relays is given by the value of 
falconNumberOfRelays.
falconRelayEntry entry .1.3.6.1.4.1.3184.1.5.1.4.1.2.1
An entry containing objects for the Falcon
output relay data and configuration.
Indexes
falconRelayIndex
Column Syntax OID
falconRelayIndex mandatory
A unique value for each output relay. Its value
ranges between 1 and the value of falconNumberOfRelays.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.4.1.2.1.1
falconRelayState mandatory
The state of use of this relay. The relay can be
set for normally open or closed. The relay can be forced
to an on or off condition, or controlled by the keypad.
Enumerationr/w
Enumerated Values:
1normallyOff
2normallyOn
3forceOn
4forceOff
5keypadControlled
8buttonControlled
9modbusControlled
.1.3.6.1.4.1.3184.1.5.1.4.1.2.1.2
falconRelayStatus mandatory
The current status for this relay.
Enumeration
Enumerated Values:
1normalOff
2normalOn
3forcedOn
4forcedOff
5keycodeActive
6alarmedActive
7scheduledActive
8buttonActive
9modbusActive
.1.3.6.1.4.1.3184.1.5.1.4.1.2.1.3
falconRelayLabel mandatory
A user-defined text string associated with this relay.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.4.1.2.1.4
falconRelayTime mandatory
The number of seconds the relay will be activated.
Set this to -1 for indefinitely.
Integer32r/w
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.4.1.2.1.5
falconRelaySchedule mandatory
The current schedule for this relay.
Enumeration
Enumerated Values:
0none
1a
2b
.1.3.6.1.4.1.3184.1.5.1.4.1.2.1.6

falconAlarmTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.5.2 · 1 row entry · 2 columns
A list of alarm table entries.  The table contains
zero, one, or many rows at any moment, depending upon
the number of alarm conditions in effect.  The table
is initially empty at agent startup.  The agent
creates a row in the table each time a condition is
detected and deletes that row when that condition no
longer pertains.  The agent creates the first row with
falconAlarmId equal to 1, and increments the value of
falconAlarmId each time a new row is created, wrapping to
the first free value greater than or equal to 1 when
the maximum value of falconAlarmId would otherwise be
exceeded.  Consequently, after multiple operations,
the table may become sparse, e.g., containing entries
for rows 95, 100, 101, and 203 and the entries should
not be assumed to be in chronological order because
falconAlarmId might have wrapped.
          
Alarms are named by an AutonomousType (OBJECT
IDENTIFIER), falconAlarmDescr, to allow a single table to
reflect well known alarms plus alarms defined by a
particular implementation, i.e., as documented in the
private enterprise MIB definition for the device.  No
two rows will have the same value of falconAlarmDescr,
since alarms define conditions.  In order to meet this
requirement, care should be taken in the definition of
alarm conditions to insure that a system cannot enter
the same condition multiple times simultaneously.
          
The number of rows in the table at any given time is
reflected by the value of falconAlarmsPresent.
falconAlarmEntry entry .1.3.6.1.4.1.3184.1.5.1.5.2.1
An entry containing information applicable to a
particular alarm.
Indexes
falconAlarmId
Column Syntax OID
falconAlarmId mandatory
A unique identifier for an alarm condition. This
value must remain constant.
PositiveInteger
Textual Convention: PositiveInteger Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.3184.1.5.1.5.2.1.1
falconAlarmDescr mandatory
A reference to an alarm description object. The
object referenced should not be accessible, but rather
be used to provide a unique description of the alarm
condition.
ObjectIdentifier .1.3.6.1.4.1.3184.1.5.1.5.2.1.2
.1.3.6.1.4.1.3184.1.5.1.7.3 · 1 row entry · 2 columns
A list of alarm history table entries stored in the
in the non-volatile memory.  The table contains zero,
one, or many rows at any moment, depending upon the
number of alarm conditions in effect. The falcon creates
a row in the table each time a new alarm is detected.
The falcon creates the first row with falconAlarmHistoryId
equal to 1, and increments the value of falconAlarmHistoryId
each time a new row is created, up to a maximum of 100.
After 100 entries are created, the falcon will overwrite
the earliest entry with the latest alarm.
The number of rows in the table at any given time is
reflected by the value of falconAlarmHistoryEntries.
falconAlarmHistoryEntry entry .1.3.6.1.4.1.3184.1.5.1.7.3.1
An entry containing information applicable to a
particular alarm history entry.
Indexes
falconAlarmHistoryId
Column Syntax OID
falconAlarmHistoryId mandatory
A unique identifier for an alarm condition. This
value must remain constant.
PositiveInteger
Textual Convention: PositiveInteger Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.3184.1.5.1.7.3.1.1
falconAlarmHistoryText mandatory
A text desciption of the alarm history entry.
Each of the strings will have the following format,
AHxxx-id-type-timestamp label
xxx = number entry in the table
id = Alarm ID
type = HIGH, LOW, ALM or RTN
timestamp = M…
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.7.3.1.2

falconBCM01CBTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.12.1.1.2 · 1 row entry · 4 columns
A table of the falcon modbus BCM CB port status.
falconBCM01CBEntry entry .1.3.6.1.4.1.3184.1.5.1.12.1.1.2.1
An entry containing objects for the Falcon modbus
BCM CB port.
Indexes
falconBCM01CBIndex
Column Syntax OID
falconBCM01CBIndex mandatory
A unique value for each BCM CB port. Its value
ranges between 1 and 42.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.1.2.1.1
falconBCM01CBStatus mandatory
The current status for this circuit breaker.
Enumeration
Enumerated Values:
0notConfigured
1offline
2normal
3zeroAmpAlarm
4warning
5alarm
.1.3.6.1.4.1.3184.1.5.1.12.1.1.2.1.2
falconBCM01CBReading mandatory
The current reading (AMPS) for circuit breaker.
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.1.2.1.3
falconBCM01CBLabel mandatory
A user-defined text string associated with the
circuit breaker.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.12.1.1.2.1.4

falconBCM02CBTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.12.1.2.2 · 1 row entry · 4 columns
A table of the falcon modbus BCM CB port status.
falconBCM02CBEntry entry .1.3.6.1.4.1.3184.1.5.1.12.1.2.2.1
An entry containing objects for the Falcon modbus
BCM CB port.
Indexes
falconBCM02CBIndex
Column Syntax OID
falconBCM02CBIndex mandatory
A unique value for each BCM CB port. Its value
ranges between 1 and 42.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.2.2.1.1
falconBCM02CBStatus mandatory
The current status for this circuit breaker.
Enumeration
Enumerated Values:
0notConfigured
1offline
2normal
3zeroAmpAlarm
4warning
5alarm
.1.3.6.1.4.1.3184.1.5.1.12.1.2.2.1.2
falconBCM02CBReading mandatory
The current reading (AMPS) for circuit breaker.
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.2.2.1.3
falconBCM02CBLabel mandatory
A user-defined text string associated with the
circuit breaker.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.12.1.2.2.1.4

falconBCM03CBTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.12.1.3.2 · 1 row entry · 4 columns
A table of the falcon modbus BCM CB port status.
falconBCM03CBEntry entry .1.3.6.1.4.1.3184.1.5.1.12.1.3.2.1
An entry containing objects for the Falcon modbus
BCM CB port.
Indexes
falconBCM03CBIndex
Column Syntax OID
falconBCM03CBIndex mandatory
A unique value for each BCM CB port. Its value
ranges between 1 and 42.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.3.2.1.1
falconBCM03CBStatus mandatory
The current status for this circuit breaker.
Enumeration
Enumerated Values:
0notConfigured
1offline
2normal
3zeroAmpAlarm
4warning
5alarm
.1.3.6.1.4.1.3184.1.5.1.12.1.3.2.1.2
falconBCM03CBReading mandatory
The current reading (AMPS) for circuit breaker.
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.3.2.1.3
falconBCM03CBLabel mandatory
A user-defined text string associated with the
circuit breaker.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.12.1.3.2.1.4

falconBCM04CBTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.12.1.4.2 · 1 row entry · 4 columns
A table of the falcon modbus BCM CB port status.
falconBCM04CBEntry entry .1.3.6.1.4.1.3184.1.5.1.12.1.4.2.1
An entry containing objects for the Falcon modbus
BCM CB port.
Indexes
falconBCM04CBIndex
Column Syntax OID
falconBCM04CBIndex mandatory
A unique value for each BCM CB port. Its value
ranges between 1 and 42.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.4.2.1.1
falconBCM04CBStatus mandatory
The current status for this circuit breaker.
Enumeration
Enumerated Values:
0notConfigured
1offline
2normal
3zeroAmpAlarm
4warning
5alarm
.1.3.6.1.4.1.3184.1.5.1.12.1.4.2.1.2
falconBCM04CBReading mandatory
The current reading (AMPS) for circuit breaker.
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.4.2.1.3
falconBCM04CBLabel mandatory
A user-defined text string associated with the
circuit breaker.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.12.1.4.2.1.4

falconBCM05CBTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.12.1.5.2 · 1 row entry · 4 columns
A table of the falcon modbus BCM CB port status.
falconBCM05CBEntry entry .1.3.6.1.4.1.3184.1.5.1.12.1.5.2.1
An entry containing objects for the Falcon modbus
BCM CB port.
Indexes
falconBCM05CBIndex
Column Syntax OID
falconBCM05CBIndex mandatory
A unique value for each BCM CB port. Its value
ranges between 1 and 42.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.5.2.1.1
falconBCM05CBStatus mandatory
The current status for this circuit breaker.
Enumeration
Enumerated Values:
0notConfigured
1offline
2normal
3zeroAmpAlarm
4warning
5alarm
.1.3.6.1.4.1.3184.1.5.1.12.1.5.2.1.2
falconBCM05CBReading mandatory
The current reading (AMPS) for circuit breaker.
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.5.2.1.3
falconBCM05CBLabel mandatory
A user-defined text string associated with the
circuit breaker.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.12.1.5.2.1.4

falconBCM06CBTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.12.1.6.2 · 1 row entry · 4 columns
A table of the falcon modbus BCM CB port status.
falconBCM06CBEntry entry .1.3.6.1.4.1.3184.1.5.1.12.1.6.2.1
An entry containing objects for the Falcon modbus
BCM CB port.
Indexes
falconBCM06CBIndex
Column Syntax OID
falconBCM06CBIndex mandatory
A unique value for each BCM CB port. Its value
ranges between 1 and 42.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.6.2.1.1
falconBCM06CBStatus mandatory
The current status for this circuit breaker.
Enumeration
Enumerated Values:
0notConfigured
1offline
2normal
3zeroAmpAlarm
4warning
5alarm
.1.3.6.1.4.1.3184.1.5.1.12.1.6.2.1.2
falconBCM06CBReading mandatory
The current reading (AMPS) for circuit breaker.
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.6.2.1.3
falconBCM06CBLabel mandatory
A user-defined text string associated with the
circuit breaker.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.12.1.6.2.1.4

falconBCM07CBTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.12.1.7.2 · 1 row entry · 4 columns
A table of the falcon modbus BCM CB port status.
falconBCM07CBEntry entry .1.3.6.1.4.1.3184.1.5.1.12.1.7.2.1
An entry containing objects for the Falcon modbus
BCM CB port.
Indexes
falconBCM07CBIndex
Column Syntax OID
falconBCM07CBIndex mandatory
A unique value for each BCM CB port. Its value
ranges between 1 and 42.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.7.2.1.1
falconBCM07CBStatus mandatory
The current status for this circuit breaker.
Enumeration
Enumerated Values:
0notConfigured
1offline
2normal
3zeroAmpAlarm
4warning
5alarm
.1.3.6.1.4.1.3184.1.5.1.12.1.7.2.1.2
falconBCM07CBReading mandatory
The current reading (AMPS) for circuit breaker.
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.7.2.1.3
falconBCM07CBLabel mandatory
A user-defined text string associated with the
circuit breaker.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.12.1.7.2.1.4

falconBCM08CBTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.12.1.8.2 · 1 row entry · 4 columns
A table of the falcon modbus BCM CB port status.
falconBCM08CBEntry entry .1.3.6.1.4.1.3184.1.5.1.12.1.8.2.1
An entry containing objects for the Falcon modbus
BCM CB port.
Indexes
falconBCM08CBIndex
Column Syntax OID
falconBCM08CBIndex mandatory
A unique value for each BCM CB port. Its value
ranges between 1 and 42.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.8.2.1.1
falconBCM08CBStatus mandatory
The current status for this circuit breaker.
Enumeration
Enumerated Values:
0notConfigured
1offline
2normal
3zeroAmpAlarm
4warning
5alarm
.1.3.6.1.4.1.3184.1.5.1.12.1.8.2.1.2
falconBCM08CBReading mandatory
The current reading (AMPS) for circuit breaker.
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.8.2.1.3
falconBCM08CBLabel mandatory
A user-defined text string associated with the
circuit breaker.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.12.1.8.2.1.4

falconBCM09CBTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.12.1.9.2 · 1 row entry · 4 columns
A table of the falcon modbus BCM CB port status.
falconBCM09CBEntry entry .1.3.6.1.4.1.3184.1.5.1.12.1.9.2.1
An entry containing objects for the Falcon modbus
BCM CB port.
Indexes
falconBCM09CBIndex
Column Syntax OID
falconBCM09CBIndex mandatory
A unique value for each BCM CB port. Its value
ranges between 1 and 42.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.9.2.1.1
falconBCM09CBStatus mandatory
The current status for this circuit breaker.
Enumeration
Enumerated Values:
0notConfigured
1offline
2normal
3zeroAmpAlarm
4warning
5alarm
.1.3.6.1.4.1.3184.1.5.1.12.1.9.2.1.2
falconBCM09CBReading mandatory
The current reading (AMPS) for circuit breaker.
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.9.2.1.3
falconBCM09CBLabel mandatory
A user-defined text string associated with the
circuit breaker.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.12.1.9.2.1.4

falconBCM10CBTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.12.1.10.2 · 1 row entry · 4 columns
A table of the falcon modbus BCM CB port status.
falconBCM10CBEntry entry .1.3.6.1.4.1.3184.1.5.1.12.1.10.2.1
An entry containing objects for the Falcon modbus
BCM CB port.
Indexes
falconBCM10CBIndex
Column Syntax OID
falconBCM10CBIndex mandatory
A unique value for each BCM CB port. Its value
ranges between 1 and 42.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.10.2.1.1
falconBCM10CBStatus mandatory
The current status for this circuit breaker.
Enumeration
Enumerated Values:
0notConfigured
1offline
2normal
3zeroAmpAlarm
4warning
5alarm
.1.3.6.1.4.1.3184.1.5.1.12.1.10.2.1.2
falconBCM10CBReading mandatory
The current reading (AMPS) for circuit breaker.
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.10.2.1.3
falconBCM10CBLabel mandatory
A user-defined text string associated with the
circuit breaker.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.12.1.10.2.1.4

falconBCM11CBTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.12.1.11.2 · 1 row entry · 4 columns
A table of the falcon modbus BCM CB port status.
falconBCM11CBEntry entry .1.3.6.1.4.1.3184.1.5.1.12.1.11.2.1
An entry containing objects for the Falcon modbus
BCM CB port.
Indexes
falconBCM11CBIndex
Column Syntax OID
falconBCM11CBIndex mandatory
A unique value for each BCM CB port. Its value
ranges between 1 and 42.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.11.2.1.1
falconBCM11CBStatus mandatory
The current status for this circuit breaker.
Enumeration
Enumerated Values:
0notConfigured
1offline
2normal
3zeroAmpAlarm
4warning
5alarm
.1.3.6.1.4.1.3184.1.5.1.12.1.11.2.1.2
falconBCM11CBReading mandatory
The current reading (AMPS) for circuit breaker.
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.11.2.1.3
falconBCM11CBLabel mandatory
A user-defined text string associated with the
circuit breaker.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.12.1.11.2.1.4

falconBCM12CBTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.12.1.12.2 · 1 row entry · 4 columns
A table of the falcon modbus BCM CB port status.
falconBCM12CBEntry entry .1.3.6.1.4.1.3184.1.5.1.12.1.12.2.1
An entry containing objects for the Falcon modbus
BCM CB port.
Indexes
falconBCM12CBIndex
Column Syntax OID
falconBCM12CBIndex mandatory
A unique value for each BCM CB port. Its value
ranges between 1 and 42.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.12.2.1.1
falconBCM12CBStatus mandatory
The current status for this circuit breaker.
Enumeration
Enumerated Values:
0notConfigured
1offline
2normal
3zeroAmpAlarm
4warning
5alarm
.1.3.6.1.4.1.3184.1.5.1.12.1.12.2.1.2
falconBCM12CBReading mandatory
The current reading (AMPS) for circuit breaker.
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.12.2.1.3
falconBCM12CBLabel mandatory
A user-defined text string associated with the
circuit breaker.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.12.1.12.2.1.4

falconBCM13CBTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.12.1.13.2 · 1 row entry · 4 columns
A table of the falcon modbus BCM CB port status.
falconBCM13CBEntry entry .1.3.6.1.4.1.3184.1.5.1.12.1.13.2.1
An entry containing objects for the Falcon modbus
BCM CB port.
Indexes
falconBCM13CBIndex
Column Syntax OID
falconBCM13CBIndex mandatory
A unique value for each BCM CB port. Its value
ranges between 1 and 42.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.13.2.1.1
falconBCM13CBStatus mandatory
The current status for this circuit breaker.
Enumeration
Enumerated Values:
0notConfigured
1offline
2normal
3zeroAmpAlarm
4warning
5alarm
.1.3.6.1.4.1.3184.1.5.1.12.1.13.2.1.2
falconBCM13CBReading mandatory
The current reading (AMPS) for circuit breaker.
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.13.2.1.3
falconBCM13CBLabel mandatory
A user-defined text string associated with the
circuit breaker.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.12.1.13.2.1.4

falconBCM14CBTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.12.1.14.2 · 1 row entry · 4 columns
A table of the falcon modbus BCM CB port status.
falconBCM14CBEntry entry .1.3.6.1.4.1.3184.1.5.1.12.1.14.2.1
An entry containing objects for the Falcon modbus
BCM CB port.
Indexes
falconBCM14CBIndex
Column Syntax OID
falconBCM14CBIndex mandatory
A unique value for each BCM CB port. Its value
ranges between 1 and 42.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.14.2.1.1
falconBCM14CBStatus mandatory
The current status for this circuit breaker.
Enumeration
Enumerated Values:
0notConfigured
1offline
2normal
3zeroAmpAlarm
4warning
5alarm
.1.3.6.1.4.1.3184.1.5.1.12.1.14.2.1.2
falconBCM14CBReading mandatory
The current reading (AMPS) for circuit breaker.
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.14.2.1.3
falconBCM14CBLabel mandatory
A user-defined text string associated with the
circuit breaker.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.12.1.14.2.1.4

falconBCM15CBTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.12.1.15.2 · 1 row entry · 4 columns
A table of the falcon modbus BCM CB port status.
falconBCM15CBEntry entry .1.3.6.1.4.1.3184.1.5.1.12.1.15.2.1
An entry containing objects for the Falcon modbus
BCM CB port.
Indexes
falconBCM15CBIndex
Column Syntax OID
falconBCM15CBIndex mandatory
A unique value for each BCM CB port. Its value
ranges between 1 and 42.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.15.2.1.1
falconBCM15CBStatus mandatory
The current status for this circuit breaker.
Enumeration
Enumerated Values:
0notConfigured
1offline
2normal
3zeroAmpAlarm
4warning
5alarm
.1.3.6.1.4.1.3184.1.5.1.12.1.15.2.1.2
falconBCM15CBReading mandatory
The current reading (AMPS) for circuit breaker.
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.15.2.1.3
falconBCM15CBLabel mandatory
A user-defined text string associated with the
circuit breaker.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.12.1.15.2.1.4

falconBCM16CBTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.12.1.16.2 · 1 row entry · 4 columns
A table of the falcon modbus BCM CB port status.
falconBCM16CBEntry entry .1.3.6.1.4.1.3184.1.5.1.12.1.16.2.1
An entry containing objects for the Falcon modbus
BCM CB port.
Indexes
falconBCM16CBIndex
Column Syntax OID
falconBCM16CBIndex mandatory
A unique value for each BCM CB port. Its value
ranges between 1 and 42.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.16.2.1.1
falconBCM16CBStatus mandatory
The current status for this circuit breaker.
Enumeration
Enumerated Values:
0notConfigured
1offline
2normal
3zeroAmpAlarm
4warning
5alarm
.1.3.6.1.4.1.3184.1.5.1.12.1.16.2.1.2
falconBCM16CBReading mandatory
The current reading (AMPS) for circuit breaker.
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.12.1.16.2.1.3
falconBCM16CBLabel mandatory
A user-defined text string associated with the
circuit breaker.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.12.1.16.2.1.4

falconXbUnitsTable

table mandatory
.1.3.6.1.4.1.3184.1.5.1.12.4.1.1 · 1 row entry · 3 columns
A table of the falcon modbus/bacnet unit status.
falconXbUnitsEntry entry .1.3.6.1.4.1.3184.1.5.1.12.4.1.1.1
An entry containing objects for the Falcon modbus/bacnet
unit status.
Indexes
falconXbUnitsIndex
Column Syntax OID
falconXbUnitsIndex mandatory
A unique value for each Modbus/bacnet unit. Its
value ranges between 1 and 16.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.12.4.1.1.1.1
falconXbUnitsStatus mandatory
The current status for this Modbus/bacnet unit.
Enumeration
Enumerated Values:
0notConfigured
1offline
2normal
3alarm
.1.3.6.1.4.1.3184.1.5.1.12.4.1.1.1.2
falconXbUnitsLabel mandatory
A user-defined text string associated with the
Modbus/bacnet unit.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.12.4.1.1.1.3
.1.3.6.1.4.1.3184.1.5.1.12.4.3 · 1 row entry · 4 columns
A table of the falcon modbus register status.
falconXbusRegisterEntry entry .1.3.6.1.4.1.3184.1.5.1.12.4.3.1
An entry containing objects for the Falcon modbus
register status.
Indexes
falconXbusRegisterIndex
Column Syntax OID
falconXbusRegisterIndex mandatory
A unique value for each Modbus register. Its
value ranges between 1 and 628.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3184.1.5.1.12.4.3.1.1
falconXbusRegisterType mandatory
The current type for this Modbus register.
Enumeration
Enumerated Values:
0notConfigured
1analog
2binary
.1.3.6.1.4.1.3184.1.5.1.12.4.3.1.2
falconXbusRegisterData mandatory
The current data value for this Modbus register.
Integer32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.3184.1.5.1.12.4.3.1.3
falconXbusRegisterLabel mandatory
A user-defined text string associated with the
modbus register.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3184.1.5.1.12.4.3.1.4