falconHumiditySensorHighLimit
RLE-FALCON-EM-MIB ·
.1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.8
Object
column
mandatory
r/w
Integer32
When the internal humidity sensor reaches or exceeds this value a trap will be generated signifying a high alarm condition.
Context
- MIB
- RLE-FALCON-EM-MIB
- OID
.1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.8- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- falconHSEntry
- Table
- falconHSTable
- Siblings
- 11
Syntax
Integer32
Values & Constraints
Object Constraints
range: -2147483648-2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| falconHSIndex mandatory A unique value for each internal humidity sensor. Its value
ranges between 1 and the value of falconNumberOfHumiditySensors. | column | Integer32 | .1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.1 |
| falconHumiditySensorLowLimit2 mandatory When the internal humidity sensor reaches or goes below this value a trap will
be generated signifying a low alarm condition. | column | Integer32 | .1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.10 |
| falconHumiditySensorDelay mandatory The number of seconds an alarm for this sensor must
be present before annunication. The range of this
setting is 0..600. | column | Integer32 | .1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.11 |
| falconHumiditySensorHysteresis mandatory The value of alarm hysteresis for this sensor.
The sensor reading must decrease or increase by this
value before the alarm will clear. | column | Integer32 | .1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.12 |
| falconHumiditySensorSchedule mandatory The current alarm disable schedule for the humidity sensor. | column | Enumeration | .1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.13 |
| falconHumiditySensorReading mandatory The reading for internal humidity sensor. | column | Integer32 | .1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.3 |
| falconHumiditySensorOffset mandatory A correction Offset associated with the sensor variable.
The value of Offset is added to the value from
internal humidity sensor to obtain the value of
the HumiditySensor variable. | column | Integer32 | .1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.4 |
| falconHumiditySensorLabel mandatory A user-defined text string associated with internal humidity sensor. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.5 |
| falconHumiditySensorUOM mandatory A user-defined text string associated with internal humidity sensor. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.6 |
| falconHumiditySensorHighLimit2 mandatory When the internal humidity sensor reaches or exceeds this value a trap will
be generated signifying a high alarm condition. | column | Integer32 | .1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.7 |
| falconHumiditySensorLowLimit mandatory When the internal humidity sensor reaches or goes below this value a trap will
be generated signifying a low alarm condition. | column | Integer32 | .1.3.6.1.4.1.3184.1.5.1.3.2.2.2.1.9 |