falconInputLabel
RLE-FALCON-EM-MIB ·
.1.3.6.1.4.1.3184.1.5.1.3.1.2.1.7
Object
A user-defined text string associated with the Input port.
Context
- MIB
- RLE-FALCON-EM-MIB
- OID
.1.3.6.1.4.1.3184.1.5.1.3.1.2.1.7- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- falconInputEntry
- Table
- falconInputTable
- Siblings
- 15
Syntax
RFC1213-MIBDisplayString
- Source
- RFC1213-MIBDisplayString
- Base type
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| falconInputIndex mandatory A unique value for each input port. Its value
ranges between 1 and the value of falconNumberOfInputPorts. | column | Integer32 | .1.3.6.1.4.1.3184.1.5.1.3.1.2.1.1 |
| falconInputHighLimit mandatory When the input port reaches or exceeds this value a trap will
be generated signifying a high alarm condition at this sensor. | column | Integer32 | .1.3.6.1.4.1.3184.1.5.1.3.1.2.1.10 |
| falconInputLowLimit mandatory When the input port reaches or goes below this value a trap will
be generated signifying a low alarm condition at this sensor. | column | Integer32 | .1.3.6.1.4.1.3184.1.5.1.3.1.2.1.11 |
| falconInputLowLimit2 mandatory When the input port reaches or goes below this value a trap will
be generated signifying a low alarm condition at this sensor. | column | Integer32 | .1.3.6.1.4.1.3184.1.5.1.3.1.2.1.12 |
| falconInputDelay mandatory The number of seconds an alarm for this input must
be present before annunication. The range of this
setting is 0..600. | column | Integer32 | .1.3.6.1.4.1.3184.1.5.1.3.1.2.1.13 |
| falconInputHysteresis mandatory The value of alarm hysteresis for this input.
The input reading must decrease or increase by this
value before the alarm will clear. | column | Integer32 | .1.3.6.1.4.1.3184.1.5.1.3.1.2.1.14 |
| falconInputSchedule mandatory The current alarm disable schedule for the input port. | column | Enumeration | .1.3.6.1.4.1.3184.1.5.1.3.1.2.1.15 |
| falconInputDigOffLabel mandatory A user-defined text string associated with the input port.
This string is used for digital off text. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3184.1.5.1.3.1.2.1.16 |
| falconInputType mandatory The installed hardware for Input Number X. If this value
is notInstalled(0) then this input is not physically installed
in the falcon. | column | Enumeration | .1.3.6.1.4.1.3184.1.5.1.3.1.2.1.2 |
| falconInputState mandatory The state of use of Input Number X. When a sensor is
connected to Input 1 set State to installed(2) to
indicate that the value of falconReading1 is valid.
When no sensor is connec… | column | Enumeration | .1.3.6.1.4.1.3184.1.5.1.3.1.2.1.3 |
| falconInputReading mandatory The reading for sensor.
If the input is digital, the reading will be 1 (active) or
0 (inactive) | column | Integer32 | .1.3.6.1.4.1.3184.1.5.1.3.1.2.1.4 |
| falconInputGain mandatory A correction gain associated with the sensor variable.
The value of gain is multiplied by the value from
Input Sensor to obtain the value of the Input variable. | column | Integer32 | .1.3.6.1.4.1.3184.1.5.1.3.1.2.1.5 |
| falconInputOffset mandatory A correction Offset associated with the sensor variable.
The value of Offset is added to the value from
the Input Sensor to obtain the value of the Input variable. | column | Integer32 | .1.3.6.1.4.1.3184.1.5.1.3.1.2.1.6 |
| falconInputUOM mandatory A user-defined text string associated with the Input port. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3184.1.5.1.3.1.2.1.8 |
| falconInputHighLimit2 mandatory When the input port reaches or exceeds this value a trap will
be generated signifying a high alarm condition at this sensor. | column | Integer32 | .1.3.6.1.4.1.3184.1.5.1.3.1.2.1.9 |