CPQNIC-MIB

Imported Objects
CPQHOST-MIB compaq cpqHoTrapFlags
CPQSINFO-MIB cpqSiServerSystemId
CPQSTDEQ-MIB cpqSePciSlotBoardName
RFC-1212 OBJECT-TYPE
RFC-1215 TRAP-TYPE
RFC1155-SMI Counter Gauge TimeTicks
RFC1213-MIB DisplayString ipAdEntAddr sysName
Objects (109)
cpqNic .1.3.6.1.4.1.232.18
cpqNicMibRev .1.3.6.1.4.1.232.18.1
cpqNicMibRevMajor mandatory Integer32 .1.3.6.1.4.1.232.18.1.1
cpqNicMibRevMinor mandatory Integer32 .1.3.6.1.4.1.232.18.1.2
cpqNicMibCondition mandatory Enumeration .1.3.6.1.4.1.232.18.1.3
cpqNicComponent .1.3.6.1.4.1.232.18.2
cpqNicInterface .1.3.6.1.4.1.232.18.2.1
cpqNicOsCommon .1.3.6.1.4.1.232.18.2.1.4
cpqNicOsCommonPollFreq mandatory r/w Integer32 .1.3.6.1.4.1.232.18.2.1.4.1
cpqNicOsCommonModuleTable obsolete .1.3.6.1.4.1.232.18.2.1.4.2
cpqNicOsCommonModuleEntry obsolete cpqNicOsCommonModuleIndex .1.3.6.1.4.1.232.18.2.1.4.2.1
cpqNicOsCommonModuleIndex obsolete Integer32 .1.3.6.1.4.1.232.18.2.1.4.2.1.1
cpqNicOsCommonModuleName obsolete OctetString .1.3.6.1.4.1.232.18.2.1.4.2.1.2
cpqNicOsCommonModuleVersion obsolete OctetString .1.3.6.1.4.1.232.18.2.1.4.2.1.3
cpqNicOsCommonModuleDate obsolete OctetString .1.3.6.1.4.1.232.18.2.1.4.2.1.4
cpqNicOsCommonModulePurpose obsolete OctetString .1.3.6.1.4.1.232.18.2.1.4.2.1.5
cpqNicIfLogMap .1.3.6.1.4.1.232.18.2.2
cpqNicIfLogMapTable mandatory .1.3.6.1.4.1.232.18.2.2.1
cpqNicIfLogMapEntry mandatory cpqNicIfLogMapIndex .1.3.6.1.4.1.232.18.2.2.1.1
cpqNicIfLogMapIndex mandatory Integer32 .1.3.6.1.4.1.232.18.2.2.1.1.1
cpqNicIfLogMapCondition mandatory Enumeration .1.3.6.1.4.1.232.18.2.2.1.1.10
cpqNicIfLogMapStatus mandatory Enumeration .1.3.6.1.4.1.232.18.2.2.1.1.11
cpqNicIfLogMapNumSwitchovers mandatory RFC1155-SMICounter .1.3.6.1.4.1.232.18.2.2.1.1.12
cpqNicIfLogMapHwLocation optional OctetString .1.3.6.1.4.1.232.18.2.2.1.1.13
cpqNicIfLogMapSpeed mandatory RFC1155-SMIGauge .1.3.6.1.4.1.232.18.2.2.1.1.14
cpqNicIfLogMapVlanCount mandatory Integer32 .1.3.6.1.4.1.232.18.2.2.1.1.15
cpqNicIfLogMapVlans mandatory OctetString .1.3.6.1.4.1.232.18.2.2.1.1.16
cpqNicIfLogMapLastChange mandatory RFC1155-SMITimeTicks .1.3.6.1.4.1.232.18.2.2.1.1.17
cpqNicIfLogMapAdvancedTeaming mandatory Integer32 .1.3.6.1.4.1.232.18.2.2.1.1.18
cpqNicIfLogMapSpeedMbps optional RFC1155-SMIGauge .1.3.6.1.4.1.232.18.2.2.1.1.19
cpqNicIfLogMapIfNumber mandatory OctetString .1.3.6.1.4.1.232.18.2.2.1.1.2
cpqNicIfLogMapIPV6Address optional RFC1213-MIBDisplayString .1.3.6.1.4.1.232.18.2.2.1.1.20
cpqNicIfLogMapLACNumber optional RFC1213-MIBDisplayString .1.3.6.1.4.1.232.18.2.2.1.1.21
cpqNicIfLogMapDHCP mandatory Enumeration .1.3.6.1.4.1.232.18.2.2.1.1.22
cpqNicIfLogMapPciLocation optional OctetString .1.3.6.1.4.1.232.18.2.2.1.1.23
cpqNicIfLogMapDescription mandatory OctetString .1.3.6.1.4.1.232.18.2.2.1.1.3
cpqNicIfLogMapGroupType mandatory Enumeration .1.3.6.1.4.1.232.18.2.2.1.1.4
cpqNicIfLogMapAdapterCount mandatory Integer32 .1.3.6.1.4.1.232.18.2.2.1.1.5
cpqNicIfLogMapAdapterOKCount mandatory Integer32 .1.3.6.1.4.1.232.18.2.2.1.1.6
cpqNicIfLogMapPhysicalAdapters mandatory OctetString .1.3.6.1.4.1.232.18.2.2.1.1.7
cpqNicIfLogMapMACAddress mandatory OctetString .1.3.6.1.4.1.232.18.2.2.1.1.8
cpqNicIfLogMapSwitchoverMode mandatory Enumeration .1.3.6.1.4.1.232.18.2.2.1.1.9
cpqNicIfLogMapOverallCondition mandatory Enumeration .1.3.6.1.4.1.232.18.2.2.2
cpqNicIfPhysAdapter .1.3.6.1.4.1.232.18.2.3
cpqNicIfPhysAdapterTable mandatory .1.3.6.1.4.1.232.18.2.3.1
cpqNicIfPhysAdapterEntry mandatory cpqNicIfPhysAdapterIndex .1.3.6.1.4.1.232.18.2.3.1.1
cpqNicIfPhysAdapterIndex mandatory Integer32 .1.3.6.1.4.1.232.18.2.3.1.1.1
cpqNicIfPhysAdapterPort mandatory Integer32 .1.3.6.1.4.1.232.18.2.3.1.1.10
cpqNicIfPhysAdapterDuplexState mandatory Enumeration .1.3.6.1.4.1.232.18.2.3.1.1.11
cpqNicIfPhysAdapterCondition mandatory Enumeration .1.3.6.1.4.1.232.18.2.3.1.1.12
cpqNicIfPhysAdapterState mandatory Enumeration .1.3.6.1.4.1.232.18.2.3.1.1.13
cpqNicIfPhysAdapterStatus mandatory Enumeration .1.3.6.1.4.1.232.18.2.3.1.1.14
cpqNicIfPhysAdapterStatsValid mandatory Enumeration .1.3.6.1.4.1.232.18.2.3.1.1.15
cpqNicIfPhysAdapterGoodTransmits mandatory RFC1155-SMICounter .1.3.6.1.4.1.232.18.2.3.1.1.16
cpqNicIfPhysAdapterGoodReceives mandatory RFC1155-SMICounter .1.3.6.1.4.1.232.18.2.3.1.1.17
cpqNicIfPhysAdapterBadTransmits mandatory RFC1155-SMICounter .1.3.6.1.4.1.232.18.2.3.1.1.18
cpqNicIfPhysAdapterBadReceives mandatory RFC1155-SMICounter .1.3.6.1.4.1.232.18.2.3.1.1.19
cpqNicIfPhysAdapterIfNumber mandatory OctetString .1.3.6.1.4.1.232.18.2.3.1.1.2
cpqNicIfPhysAdapterAlignmentErrors mandatory RFC1155-SMICounter .1.3.6.1.4.1.232.18.2.3.1.1.20
cpqNicIfPhysAdapterFCSErrors mandatory RFC1155-SMICounter .1.3.6.1.4.1.232.18.2.3.1.1.21
cpqNicIfPhysAdapterSingleCollisionFrames mandatory RFC1155-SMICounter .1.3.6.1.4.1.232.18.2.3.1.1.22
cpqNicIfPhysAdapterMultipleCollisionFrames mandatory RFC1155-SMICounter .1.3.6.1.4.1.232.18.2.3.1.1.23
cpqNicIfPhysAdapterDeferredTransmissions mandatory RFC1155-SMICounter .1.3.6.1.4.1.232.18.2.3.1.1.24
cpqNicIfPhysAdapterLateCollisions mandatory RFC1155-SMICounter .1.3.6.1.4.1.232.18.2.3.1.1.25
cpqNicIfPhysAdapterExcessiveCollisions mandatory RFC1155-SMICounter .1.3.6.1.4.1.232.18.2.3.1.1.26
cpqNicIfPhysAdapterInternalMacTransmitErrors mandatory RFC1155-SMICounter .1.3.6.1.4.1.232.18.2.3.1.1.27
cpqNicIfPhysAdapterCarrierSenseErrors mandatory RFC1155-SMICounter .1.3.6.1.4.1.232.18.2.3.1.1.28
cpqNicIfPhysAdapterFrameTooLongs mandatory RFC1155-SMICounter .1.3.6.1.4.1.232.18.2.3.1.1.29
cpqNicIfPhysAdapterRole mandatory Enumeration .1.3.6.1.4.1.232.18.2.3.1.1.3
cpqNicIfPhysAdapterInternalMacReceiveErrors mandatory RFC1155-SMICounter .1.3.6.1.4.1.232.18.2.3.1.1.30
cpqNicIfPhysAdapterHwLocation optional OctetString .1.3.6.1.4.1.232.18.2.3.1.1.31
cpqNicIfPhysAdapterPartNumber mandatory OctetString .1.3.6.1.4.1.232.18.2.3.1.1.32
cpqNicIfPhysAdapterSpeed mandatory RFC1155-SMIGauge .1.3.6.1.4.1.232.18.2.3.1.1.33
cpqNicIfPhysAdapterConfSpeedDuplex mandatory Enumeration .1.3.6.1.4.1.232.18.2.3.1.1.34
cpqNicIfPhysAdapterAggregationGID mandatory Integer32 .1.3.6.1.4.1.232.18.2.3.1.1.35
cpqNicIfPhysAdapterSpeedMbps optional RFC1155-SMIGauge .1.3.6.1.4.1.232.18.2.3.1.1.36
cpqNicIfPhysAdapterInOctets optional RFC1155-SMICounter .1.3.6.1.4.1.232.18.2.3.1.1.37
cpqNicIfPhysAdapterOutOctets optional RFC1155-SMICounter .1.3.6.1.4.1.232.18.2.3.1.1.38
cpqNicIfPhysAdapterName optional OctetString .1.3.6.1.4.1.232.18.2.3.1.1.39
cpqNicIfPhysAdapterMACAddress mandatory OctetString .1.3.6.1.4.1.232.18.2.3.1.1.4
cpqNicIfPhysAdapterIoBayNo optional Integer32 .1.3.6.1.4.1.232.18.2.3.1.1.40
cpqNicIfPhysAdapterFWVersion optional OctetString .1.3.6.1.4.1.232.18.2.3.1.1.41
cpqNicIfPhysAdapterVirtualPortNumber optional Integer32 .1.3.6.1.4.1.232.18.2.3.1.1.42
cpqNicIfPhysAdapterPciLocation optional OctetString .1.3.6.1.4.1.232.18.2.3.1.1.43
cpqNicIfPhysAdapterSlot mandatory Integer32 .1.3.6.1.4.1.232.18.2.3.1.1.5
cpqNicIfPhysAdapterIoAddr mandatory Integer32 .1.3.6.1.4.1.232.18.2.3.1.1.6
cpqNicIfPhysAdapterIrq mandatory Integer32 .1.3.6.1.4.1.232.18.2.3.1.1.7
cpqNicIfPhysAdapterDma mandatory Integer32 .1.3.6.1.4.1.232.18.2.3.1.1.8
cpqNicIfPhysAdapterMemAddr mandatory Integer32 .1.3.6.1.4.1.232.18.2.3.1.1.9
cpqNicPhyAdapBaseMemTable optional .1.3.6.1.4.1.232.18.2.3.2
cpqNicPhyAdapBaseMemEntry optional cpqNicPhyAdapBaseMemIndex .1.3.6.1.4.1.232.18.2.3.2.1
cpqNicPhyAdapBaseMemIndex optional Integer32 .1.3.6.1.4.1.232.18.2.3.2.1.1
cpqNicPhyAdapBaseMemIfIndex optional Integer32 .1.3.6.1.4.1.232.18.2.3.2.1.2
cpqNicPhyAdapBaseMemAddr optional Integer32 .1.3.6.1.4.1.232.18.2.3.2.1.3
cpqNicFlexLomPhySlot mandatory Integer32 .1.3.6.1.4.1.232.18.2.3.3
cpqNicIfVlanMap .1.3.6.1.4.1.232.18.2.4
cpqNicIfVlanMapTable mandatory .1.3.6.1.4.1.232.18.2.4.1
cpqNicIfVlanMapEntry mandatory cpqNicIfVlanMapIndex .1.3.6.1.4.1.232.18.2.4.1.1
cpqNicIfVlanMapIndex mandatory Integer32 .1.3.6.1.4.1.232.18.2.4.1.1.1
cpqNicIfVlanMapLogIndex mandatory Integer32 .1.3.6.1.4.1.232.18.2.4.1.1.2
cpqNicIfVlanMapIfIndex mandatory Integer32 .1.3.6.1.4.1.232.18.2.4.1.1.3
cpqNicIfVlanMapVlanId mandatory Integer32 .1.3.6.1.4.1.232.18.2.4.1.1.4
cpqNicIfVlanMapVlanName mandatory OctetString .1.3.6.1.4.1.232.18.2.4.1.1.5
cpqNicIfVlanMapVlanIPV6Address optional RFC1213-MIBDisplayString .1.3.6.1.4.1.232.18.2.4.1.1.6
cpqNicIfVlanMapVlanLACNumber optional RFC1213-MIBDisplayString .1.3.6.1.4.1.232.18.2.4.1.1.7
cpqNicVirusThrottle .1.3.6.1.4.1.232.18.2.5
cpqNicVtInstalled mandatory Enumeration .1.3.6.1.4.1.232.18.2.5.1
cpqNicVtLicensed mandatory Enumeration .1.3.6.1.4.1.232.18.2.5.2
cpqNicVtVirusActivity mandatory Enumeration .1.3.6.1.4.1.232.18.2.5.3
Notifications / Traps (17)
NameOIDDescription
cpqNicConnectivityRestored .1.3.6.1.4.1.232.0.18001
This trap will be sent any time connectivity is restored
to a logical adapter.  This occurs when the physical
adapter in a single adapter configuration returns to
the OK condition or at least one physical adapter
in a logical adapter group returns to the OK condition.
          
This can be caused by replacement of a faulty cable
or re-attaching a cable that was unplugged.
          
User Action: None required.
cpqNicConnectivityLost .1.3.6.1.4.1.232.0.18002
This trap will be sent any time the status of a logical
adapter changes to the Failed condition.  This occurs
when the adapter in a single adapter configuration fails,
or when the last adapter in a redundant configuration fails.
          
This can be caused by loss of link due to a cable being
removed from the adapter or the Hub or Switch.  Internal
adapter, Hub, or Switch failures can also cause this
condition.
          
User Action: Check the cables to the adapter and the Hub or
Switch.  If no cable problems are found, the adapter, Hub,
or Switch may need replacement.
cpqNicRedundancyIncreased .1.3.6.1.4.1.232.0.18003
This trap will be sent any time a previously failed physical
adapter in a connected logical adapter group returns to the OK
condition.  This trap is not sent when a logical adapter
group has connectivity restored from a Failed condition.  The
cpqNicConnectivityRestored trap is sent instead.
          
This can be caused by replacement of a faulty cable
or re-attaching a cable that was unplugged.
          
          
User Action:  None required.
cpqNicRedundancyReduced .1.3.6.1.4.1.232.0.18004
This trap will be sent any time a physical adapter in a
logical adapter group changes to the Failed condition, but
at least one physical adapter remains in the OK condition..
          
This can be caused by loss of link due to a cable being
removed from the adapter or the Hub or Switch.  Internal
adapter, Hub, or Switch failures can also cause this
condition.
          
User Action: Check the cables to the adapter and the Hub or
Switch.  If no cable problems are found, the adapter, Hub,
or Switch may need replacement.
cpqNic2ConnectivityRestored .1.3.6.1.4.1.232.0.18005
This trap will be sent any time connectivity is restored
to a logical adapter.  This occurs when the physical
adapter in a single adapter configuration returns to
the OK condition or at least one physical adapter
in a logical adapter group returns to the OK condition.
          
This can be caused by replacement of a faulty cable
or re-attaching a cable that was unplugged.
          
User Action: None required.
cpqNic2ConnectivityLost .1.3.6.1.4.1.232.0.18006
This trap will be sent any time the status of a logical
adapter changes to the Failed condition.  This occurs
when the adapter in a single adapter configuration fails,
or when the last adapter in a redundant configuration fails.
          
This can be caused by loss of link due to a cable being
removed from the adapter or the Hub or Switch.  Internal
adapter, Hub, or Switch failures can also cause this
condition.
          
User Action: Check the cables to the adapter and the Hub or
Switch.  If no cable problems are found, the adapter, Hub,
or Switch may need replacement.
cpqNic2RedundancyIncreased .1.3.6.1.4.1.232.0.18007
This trap will be sent any time a previously failed physical
adapter in a connected logical adapter group returns to the OK
condition.  This trap is not sent when a logical adapter
group has connectivity restored from a Failed condition.  The
cpqNicConnectivityRestored trap is sent instead.
          
This can be caused by replacement of a faulty cable
or re-attaching a cable that was unplugged.
          
          
User Action:  None required.
cpqNic2RedundancyReduced .1.3.6.1.4.1.232.0.18008
This trap will be sent any time a physical adapter in a
logical adapter group changes to the Failed condition, but
at least one physical adapter remains in the OK condition..
          
This can be caused by loss of link due to a cable being
removed from the adapter or the Hub or Switch.  Internal
adapter, Hub, or Switch failures can also cause this
condition.
          
User Action: Check the cables to the adapter and the Hub or
Switch.  If no cable problems are found, the adapter, Hub,
or Switch may need replacement.
cpqNicVirusLikeActivityDetected
RFC1213-MIBsysName CPQHOST-MIBcpqHoTrapFlags CPQSINFO-MIBcpqSiServerSystemId
.1.3.6.1.4.1.232.0.18009
This trap will be sent when the Virus Throttle Filter
Driver detects virus like activity.
          
User Action:  The system reporting this trap requires
immediate attention.
cpqNicVirusLikeActivityStopped
RFC1213-MIBsysName CPQHOST-MIBcpqHoTrapFlags CPQSINFO-MIBcpqSiServerSystemId
.1.3.6.1.4.1.232.0.18010
This trap will be sent when the Virus Throttle Filter
Driver no longer detects virus like activity.
          
User Action:  None required.
cpqNic3ConnectivityRestored .1.3.6.1.4.1.232.0.18011
This trap will be sent any time connectivity is restored
to a logical adapter.  This occurs when the physical
adapter in a single adapter configuration returns to
the OK condition or at least one physical adapter
in a logical adapter group returns to the OK condition.
          
This can be caused by replacement of a faulty cable
or re-attaching a cable that was unplugged.
          
User Action: None required.
cpqNic3ConnectivityLost .1.3.6.1.4.1.232.0.18012
This trap will be sent any time the status of a logical adapter changes to disconnected. If this server is powered off, booting, or shutting down, occasional connectivity alerts may occur as the network adapter negotiates with the destination device. These alerts can be ignored and should clear automatically. If this server is booted up and running an operating system, this alert can be caused by loss of connectivity due to a cable being removed, a hub, switch, or interconnect port being disabled or going bad, or an error in configuration of either the OS or the destination device such as interconnect ,blade, switch etc . Check the physical connection from the server to its destination device, including any cables. Also check the configuration of the operating system and destination device. Note that for redundant network connections, this alert will be sent only if connectivity is lost on all individual connections.
cpqNic3RedundancyIncreased .1.3.6.1.4.1.232.0.18013
This trap will be sent any time a previously failed physical
adapter in a connected logical adapter group returns to the OK
condition.  This trap is not sent when a logical adapter
group has connectivity restored from a Failed condition.  The
cpqNicConnectivityRestored trap is sent instead.
          
This can be caused by replacement of a faulty cable
or re-attaching a cable that was unplugged.
          
          
User Action:  None required.
cpqNic3RedundancyReduced .1.3.6.1.4.1.232.0.18014
This trap will be sent any time a physical adapter in a
logical adapter group changes to the Failed condition, but
at least one physical adapter remains in the OK condition..
          
This can be caused by loss of link due to a cable being
removed from the adapter or the Hub or Switch.  Internal
adapter, Hub, or Switch failures can also cause this
condition.
          
User Action: Check the connection to the adapter and validate the connectivity from the server to any external device, including the cabling. If no problems are found, the adapter or other connectivity device may need replacement.
cpqNicAllLinksDown
RFC1213-MIBsysName CPQHOST-MIBcpqHoTrapFlags cpqNicIfPhysAdapterSlot CPQSINFO-MIBcpqSiServerSystemId CPQSTDEQ-MIBcpqSePciSlotBoardName cpqNicIfPhysAdapterPartNumber
.1.3.6.1.4.1.232.0.18015
This trap will be sent any time a physical adapter has had a function up at any point and transitions to having all of its functions down  (including function types not in the cpqNic MIB). 
          
User Action: Check the connection to the adapter and validate the connectivity from the server to any external device, including the cabling. If no problems are found, the adapter or other connectivity device may need replacement.
cpqNicAllLinksDownRepaired
RFC1213-MIBsysName CPQHOST-MIBcpqHoTrapFlags cpqNicIfPhysAdapterSlot CPQSINFO-MIBcpqSiServerSystemId CPQSTDEQ-MIBcpqSePciSlotBoardName cpqNicIfPhysAdapterPartNumber
.1.3.6.1.4.1.232.0.18016
This trap will be sent any time a physical adapter has had a function up at any point and transitions to having all of its functions down  (including function types not in the cpqNic MIB) and then has one if its functions return to up. 
          
User Action: None Required
cpqNicFlexLomTrainingFailed .1.3.6.1.4.1.232.0.18017
This trap is sent when a Flexlom slot failed to train.
          
User Action: Reinstall the FlexibleLOM card. If the issue persists, update the card firmware. If the issue still persists, contact support