BRCM-CM-ENGINEERING-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
7
Rows
7
Columns
37
cmDsCalTunerCoefTable
table.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3
·
1 row entry
·
4 columns
A list of tuner coeffiencents to be used when calculating downstream power for this device.
An entry defining a tuner coefficient for a given frequency at the
given index for this device.
given index for this device.
Indexes
BRCM-CM-FACTORY-MIBcmDsCalOffsetIndex cmDsCalTunerCoefIndex
| Column | Syntax | OID |
|---|---|---|
|
cmDsCalTunerCoefIndex
Identifies the instance of this tuner coefficient.
|
Integer32 Constraints: range: 1-128 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1.1 |
|
cmDsCalTunerCoefFrequency
The downstream frequency at which this instance of
cmDsCalTunerCoefValue applies. This read-only object is provided here for convenience. Value is identical to the value of the read-write object cmDsCalOffsetFrequenc… |
hertzSNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1.2 |
|
cmDsCalTunerCoefValue
The value of this tuner coefficient multiplied by one million.
For example, a tuner coefficient value of 0.218369 would be represented as 218369. This gives a Since tuner coefficients must range in value between zero … |
millionthUnsigned32r/w Constraints: range: 0-1000000 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1.3 |
|
cmDsCalTunerCoefCopyFrom
Setting this object to the value of the first element of an index of
a row in this table will cause all coefficients for this frequency to be copied from the corresponding location in the frequency pointed to by the in… |
SNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1.4 |
cmDsCalIFCoefTable
table.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.6
·
1 row entry
·
4 columns
A list of intermediate frequency coeffiencents to be used when calculating downstream power for this device.
An entry defining an IF coefficient for a given frequency at the
given index for this device.
given index for this device.
Indexes
BRCM-CM-FACTORY-MIBcmDsCalOffsetIndex cmDsCalIFCoefIndex
| Column | Syntax | OID |
|---|---|---|
|
cmDsCalIFCoefIndex
Identifies the instance of this IF coefficient.
|
Integer32 Constraints: range: 1-128 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.6.1.1 |
|
cmDsCalIFCoefFrequency
The downstream frequency at which this instance of
cmDsCalIFCoefValue applies. This read-only object is provided here for convenience. Value is identical to the value of the read-write object cmDsCalOffsetFrequency w… |
hertzSNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.6.1.2 |
|
cmDsCalIFCoefValue
The value of this IF coefficient multiplied by one hundred thousand.
For example, an IF coefficent value of -2662.94 would be represented as -266294000. This gives an effective range of IF coefficent values ranging fro… |
hundred-thousandthSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.6.1.3 |
|
cmDsCalIFCoefCopyFrom
Setting this object to the value of the first element of an index of
a row in this table will cause all coefficients for this frequency to be copied from the corresponding location in the frequency pointed to by the in… |
SNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.6.1.4 |
cmDsCalFineCoefTable
table.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.9
·
1 row entry
·
4 columns
A list of Fine coeffiencents to be used when calculating downstream power for this device.
An entry defining a Fine coefficient for a given frequency at the
given index for this device.
given index for this device.
Indexes
BRCM-CM-FACTORY-MIBcmDsCalOffsetIndex cmDsCalFineCoefIndex
| Column | Syntax | OID |
|---|---|---|
|
cmDsCalFineCoefIndex
Identifies the instance of this Fine coefficient.
|
Integer32 Constraints: range: 1-128 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.9.1.1 |
|
cmDsCalFineCoefFrequency
The downstream frequency at which this instance of
cmDsCalFineCoefValue applies. This read-only object is provided here for convenience. Value is identical to the value of the read-write object cmDsCalOffsetFrequency… |
hertzSNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.9.1.2 |
|
cmDsCalFineCoefValue
The value of this fine coefficient multiplied by one million.
For example, a fine coefficent value of 36.5494 would be represented as 36549400. This gives an effective range of fine coefficent values ranging from -2147… |
millionthSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.9.1.3 |
|
cmDsCalFineCoefCopyFrom
Setting this object to the value of the first element of an index of
a row in this table will cause all coefficients for this frequency to be copied from the corresponding location in the frequency pointed to by the in… |
SNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.9.1.4 |
cmDsCalEqCoefTable
table.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.12
·
1 row entry
·
4 columns
A list of equalizer coeffiencents to be used when calculating downstream power for this device.
An entry defining a equalizer coefficient for a given frequency at the
given index for this device.
given index for this device.
Indexes
BRCM-CM-FACTORY-MIBcmDsCalOffsetIndex cmDsCalEqCoefIndex
| Column | Syntax | OID |
|---|---|---|
|
cmDsCalEqCoefIndex
Identifies the instance of this equalizer coefficient.
|
Integer32 Constraints: range: 1-128 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.12.1.1 |
|
cmDsCalEqCoefFrequency
The downstream frequency at which this instance of
cmDsCalEqCoefValue applies. This read-only object is provided here for convenience. Value is identical to the value of the read-write object cmDsCalOffsetFrequency w… |
hertzSNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.12.1.2 |
|
cmDsCalEqCoefValue
The value of this equalizer coefficient multiplied by one hundred
thousand. For example, an equalizer coefficent value of 4287.95 would be represented as 428795000. This gives an effective range of equalizer coeffic… |
hundred-thousandthSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.12.1.3 |
|
cmDsCalEqCoefCopyFrom
Setting this object to the value of the first element of an index of
a row in this table will cause all coefficients for this frequency to be copied from the corresponding location in the frequency pointed to by the in… |
SNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.12.1.4 |
cmDsCalTunerTable
table.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.32
·
1 row entry
·
5 columns
A table used to control all tuners present on this device.
An entry used to control an individual tuner.
Indexes
cmDsCalTunerIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
cmDsCalTunerIndex
Identifies the instance of this tuner.
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.32.1.1 |
||||
|
cmDsCalTunerType
Identifies the type of this tuner.
|
Enumeration | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.32.1.2 |
||||
|
cmDsCalTunerNumChannels
Identifies the maximum number of downstream channels which may be
tuned by this tuner in this application. Note that the value of this object depends on the annex mode, because in Annex A each channel is 8MHz in widt… |
Integer32 Constraints: range: 1-5 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.32.1.3 |
||||
|
cmDsCalTunerFrequency
The center frequency to which this tuner will tune when
cmDsCalTunerTuneNow is set to true(1). Note that a read of this object does NOT necessarily indicate that the CM is currently tuned to the indicated frequency,… |
hertzInteger32r/w Constraints: range: 0-1000000000 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.32.1.4 |
||||
|
cmDsCalTunerTuneNow
When this object is set to true(1), the tuner will tune to the
frequency specified by cmDsCalTunerFrequency. Sets to false(2) will be rejected with an inconsistentValue error. taken. When read, this object returns tru… |
SNMPv2-TCTruthValuer/w Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.32.1.5 |
cmDsCalPhyTable
table.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33
·
1 row entry
·
12 columns
A table which allows control over each individual downstream phy block present on the device.
An entry allowing control over an individual downstream phy block.
Indexes
cmDsCalPhyIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
cmDsCalPhyIndex
Identifies the instance of this phy block.
|
Integer32 Constraints: range: 1-12 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.1 |
||||
|
cmDsCalPhyTuner
Controls which tuner from the cmDsCalTunerTable this phy is mapped to.
|
Integer32r/w Constraints: range: 1-8 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.2 |
||||
|
cmDsCalPhyTunerChannel
Controls which channel of the tuner identified by cmDsCalPhyTuner is
mapped to this phy. Values are defined as offsets from the center channel of the tuner, which is represented by a value of 0 for this object. Note… |
Integer32r/w Constraints: range: -8-8 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.3 |
||||
|
cmDsCalPhyModulation
The modulation type that the CM will attempt to lock under
when cmDsCalPhyLockNow is set to true. Note that a read of this object does NOT necessarily indicate that the CM is currently locked under the indicated modul… |
Enumerationr/w | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.4 |
||||
|
cmDsCalPhyLockNow
When this object is set to true(1), the CM will attempt to lock the
downstream phy according to the parameters specified by the values of cmDsCalTunerCenterFrequency, cmDsCalPhyTuner, cmDsCalPhyTunerChannel, and cmDsCa… |
SNMPv2-TCTruthValuer/w Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.5 |
||||
|
cmDsCalPhyQamLocked
Indicates whether the last set of cmDsCalPhyLockNow to true resulted
in the phy acheiving QAM lock. The value of this object is reset whenever cmDsCalPhyLockNow is set to true, and its value will always indicate the… |
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.6 |
||||
|
cmDsCalPhyFecLocked
Indicates whether the last set of cmDsCalPhyLockNow to true resulted
in the phy acheiving FEC lock. The value of this object is reset whenever cmDsCalPhyLockNow is set to true, and its value will always indicate the… |
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.7 |
||||
|
cmDsCalPhySignalNoise
Signal/Noise ratio as perceived for this phy.
|
TenthdBDOCS-IF-MIBTenthdB Textual Convention: DOCS-IF-MIBTenthdB Integer32 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.8 |
||||
|
cmDsCalPhyPower
The received power level for this phy.
|
dBmVDOCS-IF-MIBTenthdBmV Textual Convention: DOCS-IF-MIBTenthdBmV Integer32 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.9 |
||||
|
cmDsCalPhyFrequency
Reports the frequency to which this phy is locked. The value of this
object will reflect the frequency as calculated according to the settings of cmDsCalPhyTuner and cmDsCalPhyTuner, and does not include the frequenc… |
hertzSNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.10 |
||||
|
cmDsCalPhyFrequencyError
Reports the frequency error for this phy. The actual frequency to
which the phy is locked will be the sum of the value of this object and cmDsCalPhyFrequency. If cmDsCalPhyLockNow has not been set to true(1) then th… |
hertzSNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.11 |
||||
|
cmDsCalPhySymbolRate
Reports the downstream symbol rate for this phy. If cmDsCalPhyLockNow
has not been set to true(1) then this object will report a value of 0. |
symbols per secondSNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.12 |
cmUsCalControlTable
table.1.3.6.1.4.1.4413.2.99.1.1.3.2.3.5
·
1 row entry
·
4 columns
A list of control values to be used when calculating upstream power for this device.
An entry defining the control values for a given power at the given
index for this device.
index for this device.
Indexes
cmUsCalControlIndex
| Column | Syntax | OID |
|---|---|---|
|
cmUsCalControlIndex
Identifies the instance of this pair of control values.
|
Integer32 Constraints: range: 1-128 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.3.5.1.1 |
|
cmUsCalControlPower
Indicates the upstream power level which is expected when the
amp gain and DAC attenuation are programmed as indicated in this entry. This value is read-only, its value depends on the values set in cmUsCalControlStartP… |
hundredth dBmVInteger32 Constraints: range: 0-255 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.3.5.1.2 |
|
cmUsCalControlAmpGain
Controls and reflects the amplifier gain setting used to produce
an output power equal to the value of this entry's instance of cmUsCalControlPower. |
Unsigned32r/w Constraints: range: 0-255 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.3.5.1.3 |
|
cmUsCalControlDacAtten
Controls and reflects the DAC attenuation setting used to produce
an output power equal to the value of this entry's instance of cmUsCalControlPower. |
Unsigned32r/w Constraints: range: 0-255 |
.1.3.6.1.4.1.4413.2.99.1.1.3.2.3.5.1.4 |