cmDsCalPhyLockNow

BRCM-CM-ENGINEERING-MIB · .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.5

Object

column r/w SNMPv2-TCTruthValue
When this object is set to true(1), the CM will attempt to lock the
downstream phy according to the parameters specified by the values of
cmDsCalTunerCenterFrequency, cmDsCalPhyTuner, cmDsCalPhyTunerChannel, 
and cmDsCalPhyModulation.  Note that prior to setting this object, 
the instance of cmDsCalTunerTuneNow corresponding to the value of 
cmDsCalPhyTuner must have previously been set to true(1).  Sets
of this object to false(2) will be rejected with an inconsistentValue 
error.  When read, this object returns false(2) if no lock has been
attempted, and true(1) if a lock has been attempted.  The success
or failure of an attempted lock is indicated by the values of objects
cmDsCalPhyQamLocked and cmDsCalPhyFecLocked.

Context

MIB
BRCM-CM-ENGINEERING-MIB
OID
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.5
Type
column
Access
readwrite
Status
current
Parent
cmDsCalPhyEntry
Table
cmDsCalPhyTable
Siblings
11

Syntax

SNMPv2-TCTruthValue
Source
SNMPv2-TCTruthValue
Base type
Enumeration

Values & Constraints

Type Values
1true
2false

Related Objects