eoACPwrAttributesAvgVoltage
POWER-ATTRIBUTES-MIB ·
.1.3.6.1.2.1.230.1.1.1.2
Object
column 0.1 Volt ACSNMPv2-SMIInteger32
A measured value for average of the voltage measured over an integral number of AC cycles. For a three-phase system, this is the average voltage (V1+V2+V3)/3. IEC 61850-7-4 measured value attribute 'Vol'.
Context
- MIB
- POWER-ATTRIBUTES-MIB
- OID
.1.3.6.1.2.1.230.1.1.1.2- Type
- column
- Access
- readonly
- Status
- current
- Units
- 0.1 Volt AC
- Parent
- eoACPwrAttributesEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'POWER-ATTRIBUTES-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'POWER-ATTRIBUTES-MIB::eoACPwrAttributesAvgVoltage'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'POWER-ATTRIBUTES-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'POWER-ATTRIBUTES-MIB::eoACPwrAttributesAvgVoltage.<entPhysicalIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'POWER-ATTRIBUTES-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'POWER-ATTRIBUTES-MIB::eoACPwrAttributesAvgVoltage'
Syntax
0.1 Volt ACSNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Conformance
Member of