RC-POM-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
107
.1.3.6.1.4.1.2272.1.71.1 · 1 row entry · 105 columns
Gibc SFF diagnostic info table
rcPlugOptModEntry entry .1.3.6.1.4.1.2272.1.71.1.1
Entry containing info. for a particular port
Indexes
rcPlugOptModPortIndex
Column Syntax OID
rcPlugOptModPortIndex
An index value that uniquely identifies a port on a
blade or line-card.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.1
rcPlugOptModDdmStatusMask
Each bit other than ddm-ok represents a specific error.
Any combination of error bits is allowed.
Bits
Enumerated Values:
0ddm-ok
1ddm-checksum-error
2ddm-i2c-read-error
3ddm-threshold-error
4ddm-calibration-error
5ddm-avaya-checksum-error
.1.3.6.1.4.1.2272.1.71.1.1.2
rcPlugOptModCalibration
The identifier value indicates type of calibration.
Enumeration
Enumerated Values:
1internal
2external
.1.3.6.1.4.1.2272.1.71.1.1.3
rcPlugOptModPowerMeasure
The identifier value indicates type of external power.
Enumeration
Enumerated Values:
1omi
2average
.1.3.6.1.4.1.2272.1.71.1.1.4
rcPlugOptModConnectorType
The connector type is a 16 character field that
contains ASCII characters, left-aligned and padded
on the right with ASCII spaces. This is an assigned
name that indicates some characteristic of the
layer-1 interface.
OctetString
Constraints:
range: 0-17
.1.3.6.1.4.1.2272.1.71.1.1.5
rcPlugOptModVendorName
The vendor name is a 16 character field that
contains ASCII characters, left-aligned and padded
on the right with ASCII spaces. The vendor name
shall be the full name of the corporation, a
commonly accepted abbreviation…
OctetString
Constraints:
range: 0-17
.1.3.6.1.4.1.2272.1.71.1.1.6
rcPlugOptModVendorPartNumber
The vendor part number is a 16 byte field that
contains ASCII characters, left-aligned and padded
on the right with ASCII spaces, defining the vendor
part number or product name.
OctetString
Constraints:
range: 0-17
.1.3.6.1.4.1.2272.1.71.1.1.7
rcPlugOptModVendorRevNumber
The vendor revision number is a 4-byte field that
contains ASCII characters, left-aligned and padded
on the right with ASCII spaces, defining the
vendor product revision number.
OctetString
Constraints:
range: 0-5
.1.3.6.1.4.1.2272.1.71.1.1.8
rcPlugOptModVendorSN
The vendor serial number is a 16 character field
that contains ASCII characters, left-aligned and
padded on the right with ASCII spaces, defining
the vendor serial number for the transceiver.
OctetString
Constraints:
range: 0-17
.1.3.6.1.4.1.2272.1.71.1.1.9
rcPlugOptModVendorDateCode
The date code is an 8-byte field that contains the
vendor's date code in ASCII. This field is
mandatory and takes the form: YYMMDDLC where
YY is the 2 low order digits of the year (00=2000),
MM is the month, 01 thru 12,…
OctetString
Constraints:
range: 0-9
.1.3.6.1.4.1.2272.1.71.1.1.10
rcPlugOptModPEC
This is a 16 byte left-justified ASCII field that
records the Nortel Product Equipment Code order
number for the module. Nortel part numbers are 9
bytes long, so the 10th through 16th byte should
be NULL.
OctetString
Constraints:
range: 0-17
.1.3.6.1.4.1.2272.1.71.1.1.11
rcPlugOptModCLEI
This is a 10 byte left-justified ASCII field that
records the Nortel supplied Common Language
Equipment Identifier code for the device. The CLEI
code is a Telcordia human-readable representation
of the 1D barcode.
OctetString
Constraints:
range: 0-11
.1.3.6.1.4.1.2272.1.71.1.1.12
rcPlugOptModSupportsDDM
This boolean indicates whether or not the device
supports the DDM capability.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.2272.1.71.1.1.13
rcPlugOptModAux1Monitoring
This value tells what Aux1 is measuring.The values are
as follows:

0 Auxiliary monitoring not implemented
1 APD Bias Voltage mV (units of 10 mV)
2 Reserved
3 TEC Current (mA)
4 Laser Temperature
5 L…
Integer32
Constraints:
range: 0-15
.1.3.6.1.4.1.2272.1.71.1.1.14
rcPlugOptModAux2Monitoring
This value tells you what AUX2 is measuring.The values are
as follows:

0 Auxiliary monitoring not implemented
1 APD Bias Voltage mV (units of 10 mV)
2 Reserved
3 TEC Current (mA)
4 Laser Temperature
Integer32
Constraints:
range: 0-15
.1.3.6.1.4.1.2272.1.71.1.1.15
rcPlugOptModWaveLength
Nominal transmitter output wavelength at room
temperature. It is expressed in nano-meters.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.2272.1.71.1.1.16
rcPlugOptModTemperature
This value represents the internally measured
module temperature. It is expressed in units of
1/256 of a degree Celsius and can range from -40C
to +125C with 0.0001 accuracy.The most significant byte is
the signed inte…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.17
rcPlugOptModTemperatureHighAlarmThreshold
This value represents the vendor specified high
temperature threshold. If the device
temperature exceeds this value, a temperature high
is asserted. It is expressed in the same
units as the measured temperature.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.18
rcPlugOptModTemperatureLowAlarmThreshold
This value represents the vendor specified low
temperature threshold. If the device
temperature falls below this value, a temperature
low is asserted. It is expressed in the same
units as the measured temperature.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.19
rcPlugOptModTemperatureHighWarningThreshold
This value represents the vendor specified high
temperature warning threshold. If the device
temperature exceeds this value, a temperature high
warning is asserted. It is expressed in the same
units as the measured temp…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.20
rcPlugOptModTemperatureLowWarningThreshold
This value represents the vendor specified low
temperature warning threshold. If the device
temperature falls below this value, a temperature
low warning is asserted. It is expressed in the
same units as the measured te…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.21
rcPlugOptModVoltage
This value represents the internally measured
supply voltage. It is a positive number expressed
in microvolts and can range from 0 to 65535 mV.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.22
rcPlugOptModVoltageHighAlarmThreshold
This value represents the vendor specified high
voltage threshold. If the measured voltage exceeds
this value, a high voltage is asserted. It
is a positive number expressed in microvolts.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.23
rcPlugOptModVoltageLowAlarmThreshold
This value represents the vendor specified low
voltage threshold. If the measured voltage falls
below this value, a low voltage is asserted.
It is a positive number expressed in microvolts.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.24
rcPlugOptModVoltageHighWarningThreshold
This value represents the vendor specified high
voltage warning threshold. If the measured voltage
exceeds this value, a high voltage warning is
asserted. It is a positive number expressed in
microvolts.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.25
rcPlugOptModVoltageLowWarningThreshold
This value represents the vendor specified low
voltage warning threshold. If the measured voltage
falls below this value, a low voltage warning is
asserted. It is a positive number expressed in
microvolts.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.26
rcPlugOptModBias
This value represents the internally measured
transmitter laser bias current. It is a positive
number expressed in units of 2 microamps and can
range from 0 to 131 mA with 0.0001 accuracy.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.27
rcPlugOptModBiasHighAlarmThreshold
This value represents the vendor specified high
current threshold. If the measured bias
current exceeds this value, a high current alarm
is asserted. It is a positive number expressed
in units of 2 microamps and can ran…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.28
rcPlugOptModBiasLowAlarmThreshold
This value represents the vendor specified low
current threshold. If the measured bias
current falls below this value, a low current
is asserted. It is a positive number
expressed in units of 2 microamps and can range
f…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.29
rcPlugOptModBiasHighWarningThreshold
This value represents the vendor specified high
current warning threshold. If the measured bias
current exceeds this value, a high current warning
is asserted. It is a positive number expressed in
units of 2 microamps a…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.30
rcPlugOptModBiasLowWarningThreshold
This value represents the vendor specified low
current warning threshold. If the measured bias
current falls below this value, a low current
warning is asserted. It is a positive number
expressed in units of 2 microamps…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.31
rcPlugOptModTxPower
This value represents the internally measured
coupled TX output power. It is a positive number
expressed in units of micro watts and can range
from 0 to 65.535 mW (-40 to 18.16 dBm).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.32
rcPlugOptModTxPowerHighAlarmThreshold
This value represents the vendor specified high
transmit power threshold. If the measured
transmitter power exceeds this value, a
transmitter power high is asserted. It is
a positive number expressed in units of micro
w…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.33
rcPlugOptModTxPowerLowAlarmThreshold
This value represents the vendor specified low
transmit power threshold. If the measured
transmitter power falls below this value, a
transmitter power low is asserted. It is a
positive number expressed in units of micro…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.34
rcPlugOptModTxPowerHighWarningThreshold
This value represents the vendor specified high
transmit power warning threshold. If the measured
transmitter power exceeds this value, a
transmitter power high warning is asserted. It is
a positive number expressed in …
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.35
rcPlugOptModTxPowerLowWarningThreshold
This value represents the vendor specified low
transmit power warning threshold. If the measured
transmitter power falls below this value, a
transmitter power low warning is asserted. It is
a positive number expressed i…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.36
rcPlugOptModRxPower
This value represents the internally measured
received power. It is a positive number expressed
in units of micro watts and can range from 0 to
65.535 mW (-40 to 18.16 dBm).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.37
rcPlugOptModRxPowerHighAlarmThreshold
This value represents the vendor specified high
receiver power threshold. If the measured
received power exceeds this value, a receiver
power high is asserted. It is a positive
number expressed in units of micro watts a…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.38
rcPlugOptModRxPowerLowAlarmThreshold
This value represents the vendor specified low
receiver power threshold. If the measured
received power falls below this value, a receiver
power low is asserted. It is a positive
number expressed in units of micro watts…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.39
rcPlugOptModRxPowerHighWarningThreshold
This value represents the vendor specified high
receiver power warning threshold. If the measured
received power exceeds this value, a receiver
power high warning is asserted. It is a positive
number expressed in units …
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.40
rcPlugOptModRxPowerLowWarningThreshold
This value represents the vendor specified low
receiver power warning threshold. If the measured
received power falls below this value, a receiver
power low warning is asserted. It is a positive
number expressed in unit…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.41
rcPlugOptModAux1
This represents the internally measured A/D
value specified.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.42
rcPlugOptModAux1HighAlarmThreshold
This value represents the vendor specified high
Aux1 threshold.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.43
rcPlugOptModAux1LowAlarmThreshold
This value represents the vendor specified low
Aux1 threshold.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.44
rcPlugOptModAux1HighWarningThreshold
This value represents the vendor specified high
Aux1 warning threshold.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.45
rcPlugOptModAux1LowWarningThreshold
This value represents the vendor specified low
Aux1 warning threshold.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.46
rcPlugOptModAux2
This represents the internally measured A/D
value specified.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.47
rcPlugOptModAux2HighAlarmThreshold
This value represents the vendor specified high
Aux1 threshold.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.48
rcPlugOptModAux2LowAlarmThreshold
This value represents the vendor specified low
Aux1 threshold.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.49
rcPlugOptModAux2HighWarningThreshold
This value represents the vendor specified high
Aux1 warning threshold.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.50
rcPlugOptModAux2LowWarningThreshold
This value represents the vendor specified low
Aux1 warning threshold.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.51
rcPlugOptModTemperatureStatus
Used to indicate the current temperature status
Enumeration
Enumerated Values:
1normal
2highWarning
3highAlarm
4lowWarning
5lowAlarm
.1.3.6.1.4.1.2272.1.71.1.1.52
rcPlugOptModVoltageStatus
Used to indicate the current voltage status
Enumeration
Enumerated Values:
1normal
2highWarning
3highAlarm
4lowWarning
5lowAlarm
.1.3.6.1.4.1.2272.1.71.1.1.53
rcPlugOptModBiasStatus
Used to indicate the current laser bias status
Enumeration
Enumerated Values:
1normal
2highWarning
3highAlarm
4lowWarning
5lowAlarm
.1.3.6.1.4.1.2272.1.71.1.1.54
rcPlugOptModTxPowerStatus
Used to indicate the current transmitter power
status
Enumeration
Enumerated Values:
1normal
2highWarning
3highAlarm
4lowWarning
5lowAlarm
.1.3.6.1.4.1.2272.1.71.1.1.55
rcPlugOptModRxPowerStatus
Used to indicate the current receiver power status
Enumeration
Enumerated Values:
1normal
2highWarning
3highAlarm
4lowWarning
5lowAlarm
.1.3.6.1.4.1.2272.1.71.1.1.56
rcPlugOptModAux1Status
Used to indicate the current Aux1 status
Enumeration
Enumerated Values:
1normal
2highWarning
3highAlarm
4lowWarning
5lowAlarm
.1.3.6.1.4.1.2272.1.71.1.1.57
rcPlugOptModAux2Status
Used to indicate the current Aux2 status
Enumeration
Enumerated Values:
1normal
2highWarning
3highAlarm
4lowWarning
5lowAlarm
.1.3.6.1.4.1.2272.1.71.1.1.58
rcPlugOptModQSFPTx1Bias
This value represents the internally measured transmitter
laser bias current in channel 1 of QSFP.. It is a positive
number expressed in units of 2 microamps and can range
from 0 to 131 mA with 0.0001 accuracy.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.59
rcPlugOptModQSFPTx2Bias
This value represents the internally measured transmitter
laser bias current in channel 2 of QSFP.. It is a positive
number expressed in units of 2 microamps and can range
from 0 to 131 mA with 0.0001 accuracy.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.60
rcPlugOptModQSFPTx3Bias
This value represents the internally measured transmitter
laser bias current in channel 3 of QSFP.. It is a positive
number expressed in units of 2 microamps and can range
from 0 to 131 mA with 0.0001 accuracy.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.61
rcPlugOptModQSFPTx4Bias
This value represents the internally measured transmitter
laser bias current in channel 4 of QSFP.. It is a positive
number expressed in units of 2 microamps and can range
from 0 to 131 mA with 0.0001 accuracy.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.62
rcPlugOptModQSFPTx1Power
This value represents the internally measured TX output
power in channel 1 of QSFP. It is a positive number
expressed in units of micro watts and can range from 0
to 65.535 mW (-40 to 18.16 dBm).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.63
rcPlugOptModQSFPTx2Power
This value represents the internally measured TX output
power in channel 2 of QSFP. It is a positive number
expressed in units of micro watts and can range from 0
to 65.535 mW (-40 to 18.16 dBm).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.64
rcPlugOptModQSFPTx3Power
This value represents the internally measured TX output
power in channel 3 of QSFP. It is a positive number
expressed in units of micro watts and can range from 0
to 65.535 mW (-40 to 18.16 dBm).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.65
rcPlugOptModQSFPTx4Power
This value represents the internally measured TX output
power in channel 4 of QSFP. It is a positive number
expressed in units of micro watts and can range from 0
to 65.535 mW (-40 to 18.16 dBm).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.66
rcPlugOptModQSFPRx1Power
This value represents the internally measured received
power in channel 1 of QSFP. It is a positive number
expressed in units of micro watts and can range from 0
to 65.535 mW (-40 to 18.16 dBm).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.67
rcPlugOptModQSFPRx2Power
This value represents the internally measured received
power in channel 2 of QSFP. It is a positive number
expressed in units of micro watts and can range from 0
to 65.535 mW (-40 to 18.16 dBm).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.68
rcPlugOptModQSFPRx3Power
This value represents the internally measured received
power in channel 3 of QSFP. It is a positive number
expressed in units of micro watts and can range from 0
to 65.535 mW (-40 to 18.16 dBm).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.69
rcPlugOptModQSFPRx4Power
This value represents the internally measured received
power in channel 1 of QSFP. It is a positive number
expressed in units of micro watts and can range from 0
to 65.535 mW (-40 to 18.16 dBm).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.70
rcPlugOptModQSFPTx1BiasStatus
Used to indicate the current laser bias status in
channel 1 for QSFP
Enumeration
Enumerated Values:
1normal
2highWarning
3highAlarm
4lowWarning
5lowAlarm
.1.3.6.1.4.1.2272.1.71.1.1.71
rcPlugOptModQSFPTx2BiasStatus
Used to indicate the current laser bias status in
channel 2 for QSFP
Enumeration
Enumerated Values:
1normal
2highWarning
3highAlarm
4lowWarning
5lowAlarm
.1.3.6.1.4.1.2272.1.71.1.1.72
rcPlugOptModQSFPTx3BiasStatus
Used to indicate the current laser bias status in
channel 3 for QSFP
Enumeration
Enumerated Values:
1normal
2highWarning
3highAlarm
4lowWarning
5lowAlarm
.1.3.6.1.4.1.2272.1.71.1.1.73
rcPlugOptModQSFPTx4BiasStatus
Used to indicate the current laser bias status in
channel 4 for QSFP
Enumeration
Enumerated Values:
1normal
2highWarning
3highAlarm
4lowWarning
5lowAlarm
.1.3.6.1.4.1.2272.1.71.1.1.74
rcPlugOptModQSFPTx1PowerStatus
Used to indicate the current transmitter power
status in channel 1 of QSFP
Enumeration
Enumerated Values:
1normal
2highWarning
3highAlarm
4lowWarning
5lowAlarm
.1.3.6.1.4.1.2272.1.71.1.1.75
rcPlugOptModQSFPTx2PowerStatus
Used to indicate the current transmitter power
status in channel 2 of QSFP
Enumeration
Enumerated Values:
1normal
2highWarning
3highAlarm
4lowWarning
5lowAlarm
.1.3.6.1.4.1.2272.1.71.1.1.76
rcPlugOptModQSFPTx3PowerStatus
Used to indicate the current transmitter power
status in channel 3 of QSFP
Enumeration
Enumerated Values:
1normal
2highWarning
3highAlarm
4lowWarning
5lowAlarm
.1.3.6.1.4.1.2272.1.71.1.1.77
rcPlugOptModQSFPTx4PowerStatus
Used to indicate the current transmitter power
status in channel 4 of QSFP
Enumeration
Enumerated Values:
1normal
2highWarning
3highAlarm
4lowWarning
5lowAlarm
.1.3.6.1.4.1.2272.1.71.1.1.78
rcPlugOptModQSFPRx1PowerStatus
Used to indicate the current receiver power
status in channel 1 for QSFP
Enumeration
Enumerated Values:
1normal
2highWarning
3highAlarm
4lowWarning
5lowAlarm
.1.3.6.1.4.1.2272.1.71.1.1.79
rcPlugOptModQSFPRx2PowerStatus
Used to indicate the current receiver power
status in channel 2 for QSFP
Enumeration
Enumerated Values:
1normal
2highWarning
3highAlarm
4lowWarning
5lowAlarm
.1.3.6.1.4.1.2272.1.71.1.1.80
rcPlugOptModQSFPRx3PowerStatus
Used to indicate the current receiver power
status in channel 3 for QSFP
Enumeration
Enumerated Values:
1normal
2highWarning
3highAlarm
4lowWarning
5lowAlarm
.1.3.6.1.4.1.2272.1.71.1.1.81
rcPlugOptModQSFPRx4PowerStatus
Used to indicate the current receiver power
status in channel 4 for QSFP
Enumeration
Enumerated Values:
1normal
2highWarning
3highAlarm
4lowWarning
5lowAlarm
.1.3.6.1.4.1.2272.1.71.1.1.82
rcPlugOptModExtremeSku
This is a 32 bytes field to hold the Extreme SKU number.
OctetString
Constraints:
range: 0-33
.1.3.6.1.4.1.2272.1.71.1.1.83
rcPlugOptModPowerOnCounter
This value represents the power-on counter. Host increments it
by 1 every 48 hours.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2272.1.71.1.1.84
rcPlugOptModTxDdmInitial
This value represents the Tx dB from low alarm. Host sets
it once only, after the first 48 consecutive hours of operation.
Update only if Tx_disable is not active.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.85
rcPlugOptModTxDdmLastGasp
This value represents the last gasp of Tx dB from low alarm.
Host updates it every 48 hours. Update only if Tx_disable is
not active.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.86
rcPlugOptModRxDdmInitial
This value represents the Rx dB from low alarm. Host sets
it after the first 48 consecutive hours of operation since
PMD power cycle. Update only if Rx_LOS is not asserted.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.87
rcPlugOptModRxDdmLastGasp
This value represents the last gasp of Rx dB from low alarm.
Host updates it every 48 hours. Update only if Rx_LOS is
not asserted.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.88
rcPlugOptModQSFPTx1DdmInitial
This value represents the Tx dB from low alarm on QSPF
channel 1. Host sets it once only, after the first 48 consecutive
hours of operation. Update only if Tx_disable is not active.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.89
rcPlugOptModQSFPTx1DdmLastGasp
This value represents the last gasp of Tx dB from low alarm
on QSPF channel 1. Host updates it every 48 hours. Update only
if Tx_disable is not active.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.90
rcPlugOptModQSFPRx1DdmInitial
This value represents the Rx dB from low alarm on QSPF
channel 1. Host sets it after the first 48 consecutive hours
of operation since PMD power cycle. Update only if Rx_LOS is
not asserted.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.91
rcPlugOptModQSFPRx1DdmLastGasp
This value represents the last gasp of Rx dB from low alarm
on QSPF channel 1. Host updates it every 48 hours. Update only
if Rx_LOS is not asserted.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.92
rcPlugOptModQSFPTx2DdmInitial
This value represents the Tx dB from low alarm on QSPF
channel 2. Host sets it once only, after the first 48 consecutive
hours of operation. Update only if Tx_disable is not active.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.93
rcPlugOptModQSFPTx2DdmLastGasp
This value represents the last gasp of Tx dB from low alarm
on QSPF channel 2. Host updates it every 48 hours. Update
only if Tx_disable is not active.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.94
rcPlugOptModQSFPRx2DdmInitial
This value represents the Rx dB from low alarm on QSPF
channel 2. Host sets it after the first 48 consecutive hours
of operation since PMD power cycle. Update only if Rx_LOS is
not asserted.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.95
rcPlugOptModQSFPRx2DdmLastGasp
This value represents the last gasp of Rx dB from low alarm
on QSPF channel 2. Host updates it every 48 hours. Update
only if Rx_LOS is not asserted.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.96
rcPlugOptModQSFPTx3DdmInitial
This value represents the Tx dB from low alarm on QSPF
channel 3. Host sets it once only, after the first 48 consecutive
hours of operation. Update only if Tx_disable is not active.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.97
rcPlugOptModQSFPTx3DdmLastGasp
This value represents the last gasp of Tx dB from low alarm
on QSPF channel 3. Host updates it every 48 hours. Update
only if Tx_disable is not active.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.98
rcPlugOptModQSFPRx3DdmInitial
This value represents the Rx dB from low alarm on QSPF
channel 3. Host sets it after the first 48 consecutive hours
of operation since PMD power cycle. Update only if Rx_LOS is
not asserted.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.99
rcPlugOptModQSFPRx3DdmLastGasp
This value represents the last gasp of Rx dB from low alarm
on QSPF channel 3. Host updates it every 48 hours. Update only
if Rx_LOS is not asserted.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.100
rcPlugOptModQSFPTx4DdmInitial
This value represents the Tx dB from low alarm on QSPF
channel 4. Host sets it once only, after the first 48 consecutive
hours of operation. Update only if Tx_disable is not active.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.101
rcPlugOptModQSFPTx4DdmLastGasp
This value represents the last gasp of Tx dB from low
alarm on QSPF channel 4. Host updates it every 48 hours.
Update only if Tx_disable is not active.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.102
rcPlugOptModQSFPRx4DdmInitial
This value represents the Rx dB from low alarm on QSPF
channel 4. Host sets it after the first 48 consecutive hours
of operation since PMD power cycle. Update only if Rx_LOS
is not asserted.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.103
rcPlugOptModQSFPRx4DdmLastGasp
This value represents the last gasp of Rx dB from
low alarm on QSPF channel 4. Host updates it every 48 hours.
Update only if Rx_LOS is not asserted.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2272.1.71.1.1.104
rcPlugOptModSupportExtremeExtraFeatures
This boolean indicates whether or not the device
supports the Extreme extra features.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.2272.1.71.1.1.105
.1.3.6.1.4.1.2272.1.71.3 · 1 row entry · 2 columns
Gibc QSPF table
rcPlugOptModOperEntry entry .1.3.6.1.4.1.2272.1.71.3.1
Entry containing info. for a particular port
Indexes
rcPlugOptModOperPortIndex
Column Syntax OID
rcPlugOptModOperPortIndex
An index value that uniquely identifies a port on a
blade or line-card.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.2272.1.71.3.1.1
rcPlugOptModOperReset
This boolean indicates whether or not reset the QSPF
on the port.
SNMPv2-TCTruthValuer/w
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.2272.1.71.3.1.2