rcPlugOptModAux1Monitoring

RC-POM-MIB · .1.3.6.1.4.1.2272.1.71.1.1.14

Object

column Integer32
This value tells what Aux1 is measuring.The values are
as follows:
              
0  Auxiliary monitoring not implemented
1  APD Bias Voltage mV (units of 10 mV)
2  Reserved
3  TEC Current (mA)
4  Laser Temperature
5  Laser Wavelength
6  +5V Supply Voltage
7  +3.3V Supply Voltage
8  +1.8V Supply Voltage
9  -5.2V Supply Voltage
10  +5.0V Supply Current (unit of 100 uA)
13  +3.3V Supply Current (unit of 100 uA)
14  +1.8V Supply Current (unit of 100 uA)
15  -5.2V Supply Current (unit of 100 uA)

Context

MIB
RC-POM-MIB
OID
.1.3.6.1.4.1.2272.1.71.1.1.14
Type
column
Access
readonly
Status
current
Parent
rcPlugOptModEntry
Table
rcPlugOptModTable
Siblings
104

Syntax

Integer32

Values & Constraints

Object Constraints
range: 0-15