Dell Inc. Storage Array member information
Copyright (c) 2002-2012 by Dell Inc.
All rights reserved. This software may not be copied, disclosed,
transferred, or used except in accordance with a license granted
by Dell Inc. This software embodies proprietary information
and trade secrets of Dell Inc.
a high threshold has been exceeded for any of the
enclosure temp sensors. The implementation of this trap should
not send more than one notification of this type for a sensor
in any 10 minute time span
eqlMemberHealthFanTrayRemoved
.1.3.6.1.4.1.12740.2.2.1.10
one of the fan trays have been removed from the
chassis. This results in overheating
eqlMemberHealthRAIDSetLostBlkTableFull
.1.3.6.1.4.1.12740.2.2.1.11
the RAID lost block table is full.
This usually is an indication of lost data.
eqlMemberHealthBatteryLessThan72Hours
.1.3.6.1.4.1.12740.2.2.1.12
the battery has insufficient charge to survive
a 72 hour power outage.
eqlMemberHealthRaidOrphanCache
.1.3.6.1.4.1.12740.2.2.1.13
Sent when the RAID driver finds data in the battery-backed cache with no matching disk array. Initialization will not proceed without user intervention. Call EqualLogic Support for assistance.
eqlMemberHealthRaidMultipleRaidSets
.1.3.6.1.4.1.12740.2.2.1.14
Sent when multiple valid RAIDsets were found. The array cannot choose which one to initialize. Remove all but one valid RAIDset and power-cycle the array.
eqlMemberHealthNVRAMBatteryFailed
.1.3.6.1.4.1.12740.2.2.1.15
Sent when the NVRAM battery fails . The NVRAM can no longer be used.
eqlMemberHealthhwComponentFailedCrit
.1.3.6.1.4.1.12740.2.2.1.16
Sent when a critical hardware component has failed.
eqlMemberHealthincompatControlModule
.1.3.6.1.4.1.12740.2.2.1.17
Sent when An incorrect control module has been inserted into the chassis.
eqlMemberHealthlowAmbientTemp
.1.3.6.1.4.1.12740.2.2.1.18
Sent when one or more sensors is below its critical temperature range.
eqlMemberHealthopsPanelFailure
.1.3.6.1.4.1.12740.2.2.1.19
Sent when Ops Panel is missing or broken.
eqlMemberHealthTempSensorLowThreshold
.1.3.6.1.4.1.12740.2.2.1.2
a low threshold has been exceeded for any of the
enclosure temp sensors. The implementation of this trap should
not send more than one notification of this type for a sensor
in any 10 minute time span
eqlMemberHealthemmLinkFailure
.1.3.6.1.4.1.12740.2.2.1.20
Sent when enclosure management services are unavailable.
eqlMemberHealthhighBatteryTemperature
.1.3.6.1.4.1.12740.2.2.1.21
Sent when the cache battery temperature exceeds upper limit; battery charger is disabled.
eqlMemberHealthenclosureOpenPerm
.1.3.6.1.4.1.12740.2.2.1.22
Sent when the enclosure is open for a long time.
eqlMemberHealthsumoChannelBothMissing
.1.3.6.1.4.1.12740.2.2.1.23
Sent when both the Sumo Channel cards go missing.
eqlMemberHealthsumoEIPFailureCOndition
.1.3.6.1.4.1.12740.2.2.1.24
Sent when EIP failed in Sumo.
eqlMemberHealthsumoChannelBothFailed
.1.3.6.1.4.1.12740.2.2.1.25
Sent when both the Sumo Channel cards go into failed state.
eqlMemberHealthFanSpeedHighThreshold
.1.3.6.1.4.1.12740.2.2.1.3
a high threshold has been exceeded for any of the
enclosure fan speed sensors. The implementation of this trap should
not send more than one notification of this type for a sensor
in any 10 minute time span
eqlMemberHealthFanSpeedLowThreshold
.1.3.6.1.4.1.12740.2.2.1.4
a low threshold has been exceeded for any of the
enclosure fan speed sensors. The implementation of this trap should
not send more than one notification of this type for a sensor
in any 10 minute time span
eqlMemberHealthPowerSupplyFanFailure
.1.3.6.1.4.1.12740.2.2.1.5
a failure has been detected on any of the power
supply fan speed sensors. The implementation of this trap should
not send more than one notification of this type for a sensor
in any 10 minute time span
eqlMemberHealthPowerSupplyFailure
.1.3.6.1.4.1.12740.2.2.1.6
a failure has been detected on any of the power
supplys in the PSA. The implementation of this trap should
not send more than one notification of this type for a sensor
in any 10 minute time span
eqlMemberHealthRAIDSetDoubleFaulted
.1.3.6.1.4.1.12740.2.2.1.7
the raid set has been detected to have double faulted. When
this occurs, the array will not come up.
User intervention is required to correct the issue
eqlMemberHealthBothFanTraysRemoved
.1.3.6.1.4.1.12740.2.2.1.8
both of the fan trays have been removed from the
chassis. This results in overheating
eqlMemberHealthRAIDlostCache
.1.3.6.1.4.1.12740.2.2.1.9
se the RAID driver is unable to recover the
battery-backed cache. The disk array will not initialize
without user intervention. See the Handling Lost Data section
in the Group Administration manual for more information.