igControlChannelT396

ZhoneGR303-MIB · .1.3.6.1.4.1.5504.4.3.1.2.1.4

Object

column r/w milliseconds Integer32
Value of the T396 timer for the Q931 protocol.
              
12.5.5.17.9 T396
T396 is the length of time that the RDT will 
wait for a reply to a SETUP message following 
the initial expiration of timer T303.
              
R12-459 [1328] The value of T396 shall be
provisionable from 700 ms through 14.7 seconds 
in steps of 1 second; the default shall be 14.7 
seconds.
              
R12-460 [1329] The above range is not intended 
to define acceptable response-time performance 
at the IDT, where the low-load (i.e., no other 
external stimuli requiring call processing 
activity) mean response time to a SETUP message 
shall be no greater than 500 ms.
              
Units in milliseconds.

Context

MIB
ZhoneGR303-MIB
OID
.1.3.6.1.4.1.5504.4.3.1.2.1.4
Type
column
Access
readwrite
Status
current
Units
milliseconds
Parent
igControlChannelEntry
Table
igControlChannelTable
Siblings
15

Syntax

milliseconds Integer32

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects