tlpUpsConfigEntry
TRIPPLITE-PRODUCTS ·
.1.3.6.1.4.1.850.1.1.3.1.5.1.1
Object
row
An entry containing information applicable to all input lines per each ups managed by this agent.
Context
- MIB
- TRIPPLITE-PRODUCTS
- OID
.1.3.6.1.4.1.850.1.1.3.1.5.1.1- Type
- row
- Status
- current
- Parent
- tlpUpsConfigTable
- Table
- tlpUpsConfigTable
- Children
- 18
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tlpUpsConfigInputVoltage The nominal value of the input line voltage. This value may not
be supported on all models. If not supported, this value will return
ERROR_NO_SUCH_NAME. This value may not be writ… | column | Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.1.5.1.1.1 |
| tlpUpsConfigBypassLowerLimitPercent The lowest AC input voltage allowed to be output to the load while in bypass
mode. This setting is expressed as a percentage from nominal voltage. If this
value is not supported b… | column | percent Integer32 | .1.3.6.1.4.1.850.1.1.3.1.5.1.1.10 |
| tlpUpsConfigBypassUpperLimitPercent The highest AC input voltage allowed to be output to the load while in bypass
mode. This setting is expressed as a percentage from nominal voltage. If this
value is not supported … | column | percent Integer32 | .1.3.6.1.4.1.850.1.1.3.1.5.1.1.11 |
| tlpUpsConfigBypassLowerLimitVoltage The lowest AC input voltage allowed to be output to the load while in bypass
mode. If this value is not supported by the ups, then this value will always
return ERROR_NO_SUCH_NAME. | column | Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.1.5.1.1.12 |
| tlpUpsConfigBypassUpperLimitVoltage The highest AC input voltage allowed to be output to the load while in bypass
mode. If this value is not supported by the ups, then this value will always
return ERROR_NO_SUCH_NAM… | column | Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.1.5.1.1.13 |
| tlpUpsConfigColdStart This option enables or disables the ability to turn the ups on without AC
supplied. If this value is not supported by the ups, then this value will
always return ERROR_NO_SUCH_NAM… | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.5.1.1.14 |
| tlpUpsConfigEconomicMode The configurable economic mode options for the ups. The online(0) mode is
the default configuration of most upss, which is synonymous as having the
economic mode disabled. The eco… | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.5.1.1.15 |
| tlpUpsConfigFaultAction Determines the action to take if the output needs to be shut down due to a
fault condition, limited by the type of fault incurred. When configured for
bypass(0), the ups will go t… | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.5.1.1.16 |
| tlpUpsConfigOffMode This option governs what mode the ups should go into when AC input is
available, but the load is either off or not battery backed up. If this
setting is configured for bypass(1), … | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.5.1.1.17 |
| tlpUpsConfigLineSensitivity Adjusts the AC line voltage sensitivity setting. If this value is not supported
by the ups, then this value will always return ERROR_NO_SUCH_NAME. | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.5.1.1.18 |
| tlpUpsConfigInputFrequency The nominal input frequency. On those systems which support read-write
access to this object, if there is an attempt to set this variable to a
value that is not supported, the req… | column | 0.1 Hertz SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.1.5.1.1.2 |
| tlpUpsConfigOutputVoltage The nominal value of the output voltage. This value may not be
supported on all models. If not supported, the agent reports
ERROR_NO_SUCH_NAME. This value may not be writable on a… | column | Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.1.5.1.1.3 |
| tlpUpsConfigOutputFrequency The nominal output frequency. On those systems which support read-write
access to this object, if there is an attempt to set this variable to a
value that is not supported, the re… | column | 0.1 Hertz SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.1.5.1.1.4 |
| tlpUpsConfigAudibleStatus The requested state of the audible alarm. When in the disabled state,
the audible alarm should never sound. The enabled state is self-
describing. Setting this object to muted(3) … | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.5.1.1.5 |
| tlpUpsConfigAutoBatteryTest When disabled(0), the ups will not perform an automatic battery selftest.
When set to another value, the ups will perform an automatic selftest in
the approximate period defined b… | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.5.1.1.6 |
| tlpUpsConfigAutoRestartAfterShutdown When enabled(1), the ups should autorestart after a shutdown from battery
mode if valid AC is applied. When disabled(0), the ups should not autorestart
when AC is restored and ins… | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.5.1.1.7 |
| tlpUpsConfigAutoRampOnTransition When enabled(1), the ups should perform its preconfigured ramp sequence when
valid AC is restored while in battery mode. If this value is not supported by
the ups, then this value… | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.5.1.1.8 |
| tlpUpsConfigAutoShedOnTransition When enabled(1), the ups should perform its preconfigured shed sequence when
valid AC is lost causing the ups to enter battery mode. If this value is not
supported by the ups, the… | column | Enumeration | .1.3.6.1.4.1.850.1.1.3.1.5.1.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| tlpDeviceIndex The table row index for the device. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.1.2.1.1 |