tlpUpsConfigAudibleStatus

TRIPPLITE-PRODUCTS · .1.3.6.1.4.1.850.1.1.3.1.5.1.1.5

Object

column r/w Enumeration
The requested state of the audible alarm. When in the disabled state,
the audible alarm should never sound. The enabled state is self-
describing. Setting this object to muted(3) when the audible alarm is
sounding shall temporarily silence the alarm. It will remain muted until
it would normally stop sounding and the value returned for read operations
during this period shall equal muted(3). At the end of this period, the
value shall revert to enabled(2). Writes of the value muted(3) when the
audible alarm is not sounding shall be accepted but otherwise shall have no
effect.

Context

MIB
TRIPPLITE-PRODUCTS
OID
.1.3.6.1.4.1.850.1.1.3.1.5.1.1.5
Type
column
Access
readwrite
Status
current
Parent
tlpUpsConfigEntry
Table
tlpUpsConfigTable
Siblings
17

Syntax

Enumeration

Values & Constraints

Enumerated Values
1disabled
2enabled
3muted

Related Objects

Sibling Objects