tlpAtsConfigSource1TransferResetOld
TRIPPLITE-PRODUCTS ·
.1.3.6.1.4.1.850.1.1.3.4.5.2.1.3
Object
If input source 1 voltage level is above this value, a unit connected to source 2 will transition to source 1 (if it is the preferred source). The maximum value allowed is dictated by tlpAtsConfigHighVoltageResetOld. The minimum value allowed is dictated by tlpAtsConfigSource1BrownoutSetOld. If not supported, this value will return ERROR_NO_SUCH_NAME.
Context
- MIB
- TRIPPLITE-PRODUCTS
- OID
.1.3.6.1.4.1.850.1.1.3.4.5.2.1.3- Type
- column
- Access
- readwrite
- Status
- obsolete
- Units
- 0.1 Volts
- Parent
- tlpAtsConfigVoltageRangeOldEntry
- Table
- tlpAtsConfigVoltageRangeOldTable
- Siblings
- 9
Syntax
0.1 Volts SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tlpAtsConfigHighVoltageTransferOld obsolete The maximum line voltage allowed before the unit disconnects the
AC input connection. The maximum value allowed is dictated by
tlpAtsInputHighTransferVoltageUpperBound (inclusivel… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.4.5.2.1.1 |
| tlpAtsConfigLowVoltageTransferOld obsolete The minimum line voltage allowed before the unit disconnects the
AC input connection. The maximum value allowed is dictated by
tlpAtsConfigLowVoltageResetOld. The minimum value al… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.4.5.2.1.10 |
| tlpAtsConfigHighVoltageResetOld obsolete If a unit is disconnected due to over-voltage, the line voltage has to
fall below this value before the unit re-connects the AC input connection.
The maximum value allowed is dict… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.4.5.2.1.2 |
| tlpAtsConfigSource1BrownoutSetOld obsolete This value dictates the voltage level below which source 1 goes into a
brown out condition. The maximum value allowed is dictated by
tlpAtsConfigSource1TransferResetOld. The minim… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.4.5.2.1.4 |
| tlpAtsConfigSource1TransferSetOld obsolete If input source 1 voltage level falls below this value, a unit connected to
source 1 will transition to source 2 (if it is in fair condition as denoted
by tlpAtsConfigSource2Trans… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.4.5.2.1.5 |
| tlpAtsConfigSource2TransferResetOld obsolete If input source 2 voltage level is above this value, a unit connected to
source 1 will transition to source 2 (if it is the preferred source). The
maximum value allowed is dictate… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.4.5.2.1.6 |
| tlpAtsConfigSource2BrownoutSetOld obsolete This value dictates the voltage level below which source 2 goes into a
brown out condition. The maximum value allowed is dictated by
tlpAtsConfigSource2TransferResetOld. The minim… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.4.5.2.1.7 |
| tlpAtsConfigSource2TransferSetOld obsolete If input source 2 voltage level falls below this value, a unit connected to
source 2 will transition to source 1 (if it is in fair condition as denoted
by tlpAtsConfigSource1Trans… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.4.5.2.1.8 |
| tlpAtsConfigLowVoltageResetOld obsolete If a unit is disconnected due to under-voltage or is not powered up yet, the
line voltage has to rise above this value before the unit gets connected to
the AC input connection. T… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.4.5.2.1.9 |