tlpAtsConfigLowVoltageResetOld
TRIPPLITE-PRODUCTS ·
.1.3.6.1.4.1.850.1.1.3.4.5.2.1.9
Object
If a unit is disconnected due to under-voltage or is not powered up yet, the line voltage has to rise above this value before the unit gets connected to the AC input connection. The maximum value allowed is dictated by the lesser value of tlpAtsConfigSource1TransferSetOld and tlpAtsConfigSource2TransferSetOld. The minimum value allowed is dictated by tlpAtsConfigLowVoltageTransferOld. If not supported, this value will return ERROR_NO_SUCH_NAME.
Context
- MIB
- TRIPPLITE-PRODUCTS
- OID
.1.3.6.1.4.1.850.1.1.3.4.5.2.1.9- Type
- column
- Access
- readwrite
- Status
- obsolete
- Units
- 0.1 Volts
- Parent
- tlpAtsConfigVoltageRangeOldEntry
- Table
- tlpAtsConfigVoltageRangeOldTable
- Siblings
- 9
Syntax
0.1 Volts SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tlpAtsConfigHighVoltageTransferOld obsolete The maximum line voltage allowed before the unit disconnects the
AC input connection. The maximum value allowed is dictated by
tlpAtsInputHighTransferVoltageUpperBound (inclusivel… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.4.5.2.1.1 |
| tlpAtsConfigLowVoltageTransferOld obsolete The minimum line voltage allowed before the unit disconnects the
AC input connection. The maximum value allowed is dictated by
tlpAtsConfigLowVoltageResetOld. The minimum value al… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.4.5.2.1.10 |
| tlpAtsConfigHighVoltageResetOld obsolete If a unit is disconnected due to over-voltage, the line voltage has to
fall below this value before the unit re-connects the AC input connection.
The maximum value allowed is dict… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.4.5.2.1.2 |
| tlpAtsConfigSource1TransferResetOld obsolete If input source 1 voltage level is above this value, a unit connected to
source 2 will transition to source 1 (if it is the preferred source). The
maximum value allowed is dictate… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.4.5.2.1.3 |
| tlpAtsConfigSource1BrownoutSetOld obsolete This value dictates the voltage level below which source 1 goes into a
brown out condition. The maximum value allowed is dictated by
tlpAtsConfigSource1TransferResetOld. The minim… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.4.5.2.1.4 |
| tlpAtsConfigSource1TransferSetOld obsolete If input source 1 voltage level falls below this value, a unit connected to
source 1 will transition to source 2 (if it is in fair condition as denoted
by tlpAtsConfigSource2Trans… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.4.5.2.1.5 |
| tlpAtsConfigSource2TransferResetOld obsolete If input source 2 voltage level is above this value, a unit connected to
source 1 will transition to source 2 (if it is the preferred source). The
maximum value allowed is dictate… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.4.5.2.1.6 |
| tlpAtsConfigSource2BrownoutSetOld obsolete This value dictates the voltage level below which source 2 goes into a
brown out condition. The maximum value allowed is dictated by
tlpAtsConfigSource2TransferResetOld. The minim… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.4.5.2.1.7 |
| tlpAtsConfigSource2TransferSetOld obsolete If input source 2 voltage level falls below this value, a unit connected to
source 2 will transition to source 1 (if it is in fair condition as denoted
by tlpAtsConfigSource1Trans… | column | 0.1 Volts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.850.1.1.3.4.5.2.1.8 |