| Object | Type | Syntax | OID |
|---|---|---|---|
| tmnxOesCtlCommsDown [CAUSE] The tmnxOesCtlCommsDown notification is generated when the
active CPM can't reach the OES master chassis.
[EFFECT] The OES can't be managed by the router.
… | notification | - | .1.3.6.1.4.1.6527.3.1.3.98.0.1 |
| tmnxOesNtpOutOfSync [CAUSE] The tmnxOesNtpOutOfSync notification is generated when NTP time
on the OES is not synchronized to the host router. The host router must
have NTP enabled and have recover… | notification | - | .1.3.6.1.4.1.6527.3.1.3.98.0.10 |
| tmnxOesNtpSync [CAUSE] The tmnxOesNtpSync notification is generated when NTP on the
OES is synchronized to the host router. The host router is serving
acceptable time toward the OES and the OE… | notification | - | .1.3.6.1.4.1.6527.3.1.3.98.0.11 |
| tmnxOesSwBelowMinRev [CAUSE] The tmnxOesSwBelowMinRev notification is generated when the
version of the running OES software image is below the minimum expected
version.
[EFFECT] The OES … | notification | - | .1.3.6.1.4.1.6527.3.1.3.98.0.12 |
| tmnxOesFirmwareCondition [CAUSE] The tmnxOesFirmwareCondition notification is generated when the
firmware on the card has a condition that needs to be notified to
network administrator. The value of tmn… | notification | - | .1.3.6.1.4.1.6527.3.1.3.98.0.13 |
| tmnxOesCfgFailNoMemory [CAUSE] The tmnxOesCfgFailNoMemory notification is generated when a
request to obtain dynamic memory to download a configuration to the
OES has failed.
[EFFECT] The… | notification | - | .1.3.6.1.4.1.6527.3.1.3.98.0.14 |
| tmnxOesCfgBlocked [CAUSE] This event tmnxOesCfgBlocked notification is generated when a
configuration being made in the OES is blocked.
[EFFECT] The configuration is not active in the… | notification | - | .1.3.6.1.4.1.6527.3.1.3.98.0.15 |
| tmnxOesSwUpgdCleanupFailed [CAUSE] This event tmnxOesSwUpgdCleanupFailed notification is
generated when the operation to clean-up a failed software upgrade
fails. The reason for the failure is specified … | notification | - | .1.3.6.1.4.1.6527.3.1.3.98.0.16 |
| tmnxOesCtlCommsUp [CAUSE] The tmnxOesCtlCommsUp notification is generated when the
active CPM can reach the OES master chassis.
[EFFECT] The OES can be managed by the router.
… | notification | - | .1.3.6.1.4.1.6527.3.1.3.98.0.2 |
| tmnxOesDbSyncFailure The active Equipment Controller is unable to synchronize its database
with the inactive Equipment Controller.
[CAUSE] The tmnxOesDbSyncFailure notification may be rai… | notification | - | .1.3.6.1.4.1.6527.3.1.3.98.0.3 |
| tmnxOesDbSyncFailureClear [CAUSE] The tmnxOesDbSyncFailureClear notification is generated when
the active Equipment Controller is able to synchronize its database
with the inactive Equipment Controller.
… | notification | - | .1.3.6.1.4.1.6527.3.1.3.98.0.4 |
| tmnxOesDbInvalid [CAUSE] The tmnxOesDbInvalid notification may be raised under the
following conditions:
1) During initial installation, if the OES is not properly
commissioned;
2) The … | notification | - | .1.3.6.1.4.1.6527.3.1.3.98.0.5 |
| tmnxOesDbInvalidClear [CAUSE] The tmnxOesDbInvalidClear notification is generated when the
active Equipment Controller previously under tmnxOesDbInvalid
condition now contains a valid database.
… | notification | - | .1.3.6.1.4.1.6527.3.1.3.98.0.6 |
| tmnxOesDbUnsync [CAUSE] The tmnxOesDbUnsync notification is generated when the active
and standby Equipment Controllers are not in sync.
[EFFECT] The OES does not have redundancy prot… | notification | - | .1.3.6.1.4.1.6527.3.1.3.98.0.7 |
| tmnxOesDbUnsyncClear [CAUSE] The tmnxOesDbUnsyncClear notification is generated when the
previously out of sync database is now synchronized between the
active and standby Equipment Controller cards.… | notification | - | .1.3.6.1.4.1.6527.3.1.3.98.0.8 |
| tmnxOesSwUpgdFailed [CAUSE] The tmnxOesSwUpgdFailed notification is generated when a
failure occurs in upgrading a component in the OES. This notification
is applicable at the NE (Network Element) … | notification | - | .1.3.6.1.4.1.6527.3.1.3.98.0.9 |