tmnxOesDbInvalid

TIMETRA-OES-MIB · .1.3.6.1.4.1.6527.3.1.3.98.0.5

Object

notification
[CAUSE] The tmnxOesDbInvalid notification may be raised under the 
following conditions:
  1) During initial installation, if the OES is not properly 
     commissioned;
  2) The serial number in the database does not match that of the OES 
     either because the controller was replaced or the alarm card was 
     replaced;
  3) A downgrade of OES software has occurred;
  4) Equipment Controller is removed/reseated during a system process, 
     causing file corruption;
  5) The database audit failed indicating some type of corruption of 
     the database.
          
[EFFECT] The OES is not in a normal operating mode. It does not have 
the correct configuration and the state of its cards is unpredictable.
As a result, the OES will not boot normally and not all commands are 
allowed.
          
[RECOVERY] A database corruption on the OES requires that the OES be 
re-commissioned. The correct database is held in the host system so 
it will be restored to the shelf once the existing database is cleared 
and the host re-establishes communication with the OES.