tmnxOesDbSyncFailure

TIMETRA-OES-MIB · .1.3.6.1.4.1.6527.3.1.3.98.0.3

Object

notification
The active Equipment Controller is unable to synchronize its database 
with the inactive Equipment Controller. 
          
[CAUSE] The tmnxOesDbSyncFailure notification may be raised under the 
following conditions:
  1) An incorrectly seated Equipment Controller;
  2) The software versions on the active and inactive Equipment 
     Controllers are not compatible;
  3) A hardware problem with one or both controllers.
          
[EFFECT] The OES does not have redundancy protection between the two 
Equipment Controller cards.  
          
[RECOVERY] Proceed as follows to clear the Database Synchronization 
Failed alarm:
  1) Remove the Equipment Controller with the condition and examine 
     the connector on the back of the card for damage, including bent 
     or broken pins;
  2) Examine the connector on the backplane for damage. If there is 
     damage to the backplane of the shelf, contact your service 
     representative;
  3) Re-insert the Equipment Controller into its original slot and 
     allow the card to initialize;
  4) Repeat Step 2) through Step 4) for the second Equipment 
     Controller;
  5) Replace the Equipment Controller with the alarm condition with a 
     new unit. If the condition is not cleared, replace the second 
     Equipment Controller with a new unit.
Follow the return and repair process to return the faulty card to 
an authorized repair center for replacement.

Context

MIB
TIMETRA-OES-MIB
OID
.1.3.6.1.4.1.6527.3.1.3.98.0.3
Type
notification
Status
current
Parent
tmnxOesNotifications
Siblings
15

Syntax

No syntax metadata recorded.

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects
Notification Objects