tmnxOesDbUnsync

TIMETRA-OES-MIB · .1.3.6.1.4.1.6527.3.1.3.98.0.7

Object

notification
[CAUSE] The tmnxOesDbUnsync notification is generated when the active 
and standby Equipment Controllers are not in sync.
          
[EFFECT] The OES does not have redundancy protection between the two 
Equipment Controller cards. If a switchover were to occur, then the 
database of the newly active controller might not reflect the latest 
configuration.
          
[RECOVERY] Proceed as follows to clear the Database Unsynchronization 
alarm:
  1) Perform a warm reset of the standby controller;
  2) If step 1 does not clear the alarm condition, then contact the 
     next level of technical support for help.