tmnxIsisIDLenMismatch

TIMETRA-ISIS-NG-MIB · .1.3.6.1.4.1.6527.3.1.3.88.0.5

Object

notification
[CAUSE] The tmnxIsisIDLenMismatch notification is sent when we receive
a PDU with a different value of the System ID Length.
          
This notification includes the index to identify the circuit where we
saw the PDU and the header of the PDU which may help a network manager
identify the source of the confusion.
          
This should be an edge-triggered notification. We should not send a
second notification about PDUs received from what seem to be the same
source. This decision is up to the agent to make, and may be based on
the circuit or on some MAC level information.
          
[EFFECT] No effect.
          
[RECOVERY] No recovery is necessary.