fsMIRstFlushIndicationThreshold

SUPERMICRO-MIRSTP-MIB · .1.3.6.1.4.1.10876.101.1.119.1.3.1.22

Object

column r/w Integer32
This indicates the number of flush indications to go before
timer method triggers. (i.e) The number of flush indications
	 to trigger the FlushInterval Timer. 
              	 
	 This value can be configurable only when fsMIRstFlushInterval
	 is other than default value. 
              	 
	 When the value is retained as default value and flush interval 
	 is being configured other than default value(0), then 
	 global flushing will happen. 
              	 
	 When this value is non-default and the flush interval is being 
	 configured other than default value(0), then the port
	 based flushing will happen until the actual flush indication 
	 reaches the threshold. Once the threshold is reached, timer 
	 will be started and during timer expiry gloabl flushing will 
	 happen.

Context

MIB
SUPERMICRO-MIRSTP-MIB
OID
.1.3.6.1.4.1.10876.101.1.119.1.3.1.22
Type
column
Access
readwrite
Status
current
Parent
fsMIDot1wFutureRstEntry
Table
fsMIDot1wFutureRstTable
Siblings
24

Syntax

Integer32

Values & Constraints

Object Constraints
range: 0-65535

Related Objects

Sibling Objects