column r/w milliseconds Unsigned32
This object is used to configure the period for  Wait to Block 
timer.
              
This object is effective, only when  Force switch or Manual switch is configured 
in the ring and when clear command is issued to recover the ring from force switch or 
manual switch.           
              
The WTB timer is defined to be 5 seconds longer than the guard timer.
[Reference : Section 10.1.4 of ITU-T G.8032 Y.1344 (03/2010)]
              
The WTB timer has a period from 0 to 24 hour, configurable in units 
of 1 millisecond. For example, to configure WTB timer  as 1 second
configure the value as 1000.

Context

MIB
SUPERMICRO-ERPS-MIB
OID
.1.3.6.1.4.1.10876.101.2.40.2.3.1.9
Type
column
Access
readwrite
Status
current
Units
milliseconds
Parent
fsErpsRingConfigEntry
Table
fsErpsRingConfigTable
Siblings
16

Syntax

milliseconds Unsigned32

Values & Constraints

Object Constraints
range: 0-86400000