fsErpsRingConfigPeriodicTime

SUPERMICRO-ERPS-MIB · .1.3.6.1.4.1.10876.101.2.40.2.3.1.4

Object

column r/w milliseconds Unsigned32
This object is used to configure the periodic timer.  Periodic timer
is used to configure the transmission interval of R-APS PDUs. Periodic
timer is not valid for the first 3 R-APS PDU transmission, that will
be send on any change of R-APS information.
              
The configured value of this timer is applicable only from the next
start/re-start of the timer.
              
The periodic timer has a period from 1 ms to 1 hour, configurable in
units of 1ms.For example, to configure Periodic timer value as 1 minute,
configure the value as 60000. Default periodic timer value is 5 seconds.

Context

MIB
SUPERMICRO-ERPS-MIB
OID
.1.3.6.1.4.1.10876.101.2.40.2.3.1.4
Type
column
Access
readwrite
Status
current
Units
milliseconds
Parent
fsErpsRingConfigEntry
Table
fsErpsRingConfigTable
Siblings
16

Syntax

milliseconds Unsigned32

Values & Constraints

Object Constraints
range: 1-3600000

Related Objects