heRFSwitchControl
SCTE-HMS-HE-RF-SWITCH-MIB ·
.1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1.2
Object
column
r/w
Enumeration
Sets the intended state of the RF Switch. The effect
of this control will depend on the value of heRFSwitchMode.
If heRFSwitchMode is set to automatic, the value this
control is set to will be the preferred setting. If it is
set to manual, the switch will assume this setting. Actual
switch operation while changing switch control value(s)
is up to the equipment vendor. For example, if the switch
is in manual mode and the operator tries to connect the
output to an invalid input, the switch may or may
not change state.
Not all enumerations must be supported. For example, an
A-B RF switch may support only the pathA and pathB
enumerations while a cross-bar switch may support cross,
bar, bothA or bothB or only cross and bar but not pathA
and pathB enumerations. See the note below about the
expected SNMP response.
A value pathA(1) connects the switch output to side A
(first input) of the switch. This enumeration is intended
for use by an A-B switch.
A value pathB(2) connects the switch output to side B
(second input) of the switch. This enumeration is intended
for use by an A-B switch.
A value cross(3) connects the switch outputs to the inputs
as follows:
Side A (first or primary) output is connected to side B
(second or alternate) input.
Side B (second or alternate) output is connected to
side A (first or primary) input.
This enumeration is intended for use by a cross-bar switch.
A value bar(4) connects the switch outputs to the inputs as
follows:
Side A (first or primary) output is connected to side A
(first or primary) input.
Side B (second or alternate) output is connected to
side B (second or alternate) input.
This enumeration is intended for use by a cross-bar switch.
A value bothA(5) connects the switch outputs to the inputs as
follows:
Side A (first or primary) output is connected to side A
(first or primary) input.
Side B (second or alternate) output is connected to
side A (first or primary) input.
This enumeration is intended for use by a cross-bar switch.
A value bothB(6) connects the switch outputs to the inputs
as follows:
Side A (first or primary) output is connected to side B
(second or alternate) input.
Side B (second or alternate) output is connected to
side B (second or alternate) input.
This enumeration is intended for use by a cross-bar switch.
*** IMPORTANT ***
It is NOT required that an RF switch support all
enumerations. A SET request for an unsupported value shall
yield a badValue(3) error by an SNMPv1 agent or an
inconsistentValue(12) by an SNMPv2 agent.
Context
- MIB
- SCTE-HMS-HE-RF-SWITCH-MIB
- OID
.1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- heRFSwitchUnitEntry
- Table
- heRFSwitchUnitTable
- Siblings
- 8
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| heRFSwitchMode This controls and/or reports the switching mode. If
automatic(1), the RF switch will evaluate the RF
input status and make the decision to affect the switch state.
If set to … | column | Enumeration | .1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1.1 |
| heRFSwitchRevertEnable This controls the use of revert switching.
If set to on, the switch will attempt to go back to the
preferred settings indicated by heRFSwitchControl if
heRFSwit… | column | SCTE-HMS-HEADENDIDENT-MIBHeOnOffControl | .1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1.3 |
| heRFSwitchState Reports the state of the RF Switch. Not all enumerations
must be supported. For example, an A-B RF switch may
support only the pathA and pathB enumerations while a
cross-bar … | column | Enumeration | .1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1.4 |
| heRFSwitchFailoverStatus The integral status of both inputs.
A value is fault(2), if current switch state heRFSwitchState
is different than the preferred setting heRFSwitchControl,
o… | column | SCTE-HMS-HEADENDIDENT-MIBHeFaultStatus | .1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1.5 |
| heRFSwitchBothInputStatus The integral status of both inputs.
A value is fault(2), if both input levels are below
the nominal value; otherwise, it is normal(1).
This object m… | column | SCTE-HMS-HEADENDIDENT-MIBHeFaultStatus | .1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1.6 |
| heRFSwitchHysteresis Controls switch input hysteresis amount. The amount of hysteresis
used and the ability to change it is to be determined by
the vendor. | column | 0.1 dB Integer32 | .1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1.7 |
| heRFSwitchWaitToRestoreTime Controls hysteresis time in sec.
If in automatic switching mode and revert mode is enabled,
a switch back to the original side will be delayed for
the time sp… | column | 1 sec SNMPv2-SMIInteger32 | .1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1.8 |
| heRFSwitchSensorMode Controls what source will be used for determining input
status:
A value of internal(1) causes the internal RF detection
circuitry to be used.
A value of external(2) will u… | column | Enumeration | .1.3.6.1.4.1.5591.1.11.4.2.1.1.1.1.9 |