column r/w Integer32
This object allows the user to place a limit on the number of times 
a test running periodically shall run.
- 0 : Run indefinitely at the periodic rate set via rcTlsTestTdcPeriodicRate.
-  1 .. 1440 : Run this number of times at the periodic rate set via 
  rcTlsTestTdcPeriodicRate.
The maximum allowable value of 1440 allows the user to run at the maximum 
periodic rate of once-per-minute for a 24-hour period.
Beware of the maximum number of samples which may be saved via the 
              
TDC history table if you wish to save all the results of a peri-odic TDC test.
This value cannot be changed if a test is currently running periodically.  
Periodic testing can be halted via rcTlsTestTdcPeriodic-Control.

Context

MIB
RC-TLS-MIB
OID
.1.3.6.1.4.1.2272.1.52.1.1.1.1.30
Type
column
Access
readwrite
Status
current
Parent
rcTlsTestTdcEntry
Table
rcTlsTestTdcTable
Siblings
45

Syntax

Integer32

Values & Constraints

Object Constraints
range: 0-1440