prtSTstDuration

RAD-MIB · .1.3.6.1.4.1.164.3.1.4.1.1.1.11

Object

column r/w SNMPv2-SMIInteger32
This attribute indicates the maximum duration of executing
a test on the specific port. This entry applies to all the
test operations. The resolution will be a minute, and the
maximum duration is limited to 30 minutes.
              
For Vmux devices, the values are in seconds.
              
A zero  value specifies no time limitation.
When the test isn't active, the agent initiates this object to
2 when the duration is needed and to 0 if its not required.
The user should set this parameter after setting the
'prtSTstCmd' parameter.

Context

MIB
RAD-MIB
OID
.1.3.6.1.4.1.164.3.1.4.1.1.1.11
Type
column
Access
readwrite
Status
current
Parent
prtSInstEntry
Table
prtSInstTable
Siblings
16

Syntax

SNMPv2-SMIInteger32
Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647

Related Objects