optWaitToRestore
RAD-MIB ·
.1.3.6.1.4.1.164.3.5.1.1.22
Object
This parameter defines the time (sec) device has to wait in the redundant state until it goes back to the default Link.
Context
- MIB
- RAD-MIB
- OID
.1.3.6.1.4.1.164.3.5.1.1.22- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- optMxConfigEntry
- Table
- optMxConfigTable
- Siblings
- 26
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| optIndex optIndex = 1 is for local Optimux.
optIndex = 2 is for remote Optimux. | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.1 |
| optRedundancyStatus If there are two modules 'links', then this field
should be set to available(2). If there is only one
module 'link', this field should be set to notAvailable(3). | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.10 |
| optRedundancyCnf This object is used by Optimux-XL, FomiE3/T3, Optimux-T3 and Optimux-155.
For Optimux-XL:
If optRedundancyStatus = notAvailable(3), then this field
can be off(2) or forcedBU(6… | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.11 |
| optFarEndType Far-End type of product.
This object is especially relevant for the local optimux.
notApplicable - for devices that don't have a far-end unit. | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.12 |
| optServiceChEnable Service Channel Enable/Disable for each Optimux (local/remote). | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.13 |
| optMaskChAlr Mask Channel Alarm.
This object is applicable only for Optimux cards.
The value of this object is a sum of 2**n, where n is a bit assigned to
a certain Channel. Bit='1' means ma… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.5.1.1.14 |
| optAisEnable AIS enable/disable.
notApplicable - for devices that do not support this feature. | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.15 |
| optFarMng This object is used by Optimux-XL and FomiE3/T3.
Is there possibility of Far-End Management (no/yes).
This object is applicable only for the Local device.
notApplicable - for Remo… | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.16 |
| optClockDivision This object is applicable only for FomiE3/T3 having an HSSI Electrical
interface.
It gives the possibility of Clock Division, so that Clock Rate will
be less than T3/E3.
notApplic… | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.17 |
| optDteLoopEnable DTE Loop enable/disable (for example loop command requested
by router).
This object is applicable only for products having HSSI interface.
notApplicable - for devices that do… | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.18 |
| optGrpClockSourcePrt This object is applicable for Optimux-T3, when optGrpClockSource=localExternal.
It enables the user to select the Channel or Station Clock from which
the Clock is received.
Valid… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.5.1.1.19 |
| optHWVersion HW Version of the device. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.164.3.5.1.1.2 |
| optIncomingAlarm State of the Incoming Alarm (On/Off), via Alarm Relay connector.
This object is applicable only for Optimux-T3. | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.20 |
| optDefChannelSet Default configuration for all Optimux Channels: T1 or E1.
This object is applicable only for Optimux-T3. | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.21 |
| optEnforcedLink This parameter is not applicable when optRedundancyCnf = off.
It enables user to enforce a Link in spite of the redundancy mechanism.
Selecting the noEnforcement(2) value cause re… | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.23 |
| optFlipUponEvent This object allows user to define if Flip to the other port will
be performed (or not), for certain possible events.
Each event is represented by a bit. The value of the object is… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.5.1.1.24 |
| optHwMaskChAlr Mask Channel Alarm done by the HW dip-switches.
This object is applicable only for Optimux cards.
The value of this object is a sum of 2**n, where n is a bit assigned to
a certai… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.5.1.1.25 |
| optServiceChExist Service Channel Existence indication for each Optimux (local/remote). | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.26 |
| optMaskSystemAlr Mask all system alarms for each Optimux (local/remote). | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.27 |
| optSWVersion SW Version of the device. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.164.3.5.1.1.3 |
| optPSPrimary The status of the primary Power Supply Unit. | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.4 |
| optPSSecondary The status of the secondary Power Supply Unit. | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.5 |
| optLinkActive This object indicates which link is active.
For Optimux-4 it may be: 5, 6 or 105, 106
For FOMi-E3/T3 it may be: 51, 61 or 151, 161.
For Optimux-T3 it may be: 51 or 61.
For Optimu… | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.164.3.5.1.1.6 |
| optSelectLink This object is used by Optimuxes.
- For Optimux 4E1/T1 Old Look:
This MIB object enables the user to force the device to use specific link.
autoredundancy= Main (Link 1) is the… | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.7 |
| optGrpPayLoadLoop Performs payload loop ( remote loop) to 4 E1 channels
at once. | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.8 |
| optGrpClockSource For Optimux XL:
If dsx3TransmitClockSource = localTiming(2), then the user
can configure this field as:
localInternal(2) = use the internal clock of the device
localExternal(3) = … | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.9 |