optRedundancyCnf

RAD-MIB · .1.3.6.1.4.1.164.3.5.1.1.11

Object

column r/w Enumeration
This object is used by Optimux-XL, FomiE3/T3, Optimux-T3 and Optimux-155.
For Optimux-XL:
  If optRedundancyStatus = notAvailable(3), then this field
  can be off(2) or forcedBU(6). 
   - off(2) = forcedMain:	forces the device to start immediately use of 
              Main (Link 1), no matter what is its state and stay there
	     - forcedBU(6)  =  forces the device to start immediately use of 
	                       Backup (Link 2),	no matter what is its state and stay there.
						   This value is not supported by Optimux-T3.
  Else, user can configure this field as:
  auto(3) = switch back to main link when valid.
  manual(4) = don't switch back to main link = automatic w/o return.
For FomiE3/T3 all values are applicable unconditioned.
For Optimux-T3 and OP-4 New Look, values off(2), auto(3), manual(4) 
  are applicable unconditioned.
For Optimux-155/1 values off (2) = Protection Lockout, auto (3) and manual (4)
and autoNonRevertive (7)

Context

MIB
RAD-MIB
OID
.1.3.6.1.4.1.164.3.5.1.1.11
Type
column
Access
readwrite
Status
current
Parent
optMxConfigEntry
Table
optMxConfigTable
Siblings
26

Syntax

Enumeration

Values & Constraints

No enumerated values or constraints recorded.

Related Objects