optSelectLink
RAD-MIB ·
.1.3.6.1.4.1.164.3.5.1.1.7
Object
column
r/w
Enumeration
This object is used by Optimuxes.
- For Optimux 4E1/T1 Old Look:
This MIB object enables the user to force the device to use specific link.
autoredundancy= Main (Link 1) is the default link. When it will fail, the
device will use Backup (Link 2). If Main recovers, it
automatically returns to Main.
autoWoReturn = Automatic Without Return. Main (Link 1) is the default link.
When it will fail, the device will use Backup (Link 2).
If Main recovers, it will NOT return to Main. It will
continue using Backup.
This option is supported only by LRS cards.
main = Forces the device to start immediately use of Main (Link 1),
no matter what is its state and stay there. No Redundancy.
back = Forces the device to start immediately use of Backup (Link 2),
no matter what is its state and stay there. No Redundancy.
- For Optimux-T3, Optimux-155, Optimux-XL and OP-4 (New Look):
This MIB object is used to select which Link will be used as MAIN.
Therefore:
autoredundancy - not supported
main = Link A is MAIN (=default).
back = Link B is MAIN.
Context
- MIB
- RAD-MIB
- OID
.1.3.6.1.4.1.164.3.5.1.1.7- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- optMxConfigEntry
- Table
- optMxConfigTable
- Siblings
- 26
Syntax
Enumeration
Values & Constraints
Enumerated Values
2 | auto |
3 | manual |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| optIndex optIndex = 1 is for local Optimux.
optIndex = 2 is for remote Optimux. | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.1 |
| optRedundancyStatus If there are two modules 'links', then this field
should be set to available(2). If there is only one
module 'link', this field should be set to notAvailable(3). | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.10 |
| optRedundancyCnf This object is used by Optimux-XL, FomiE3/T3, Optimux-T3 and Optimux-155.
For Optimux-XL:
If optRedundancyStatus = notAvailable(3), then this field
can be off(2) or forcedBU(6… | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.11 |
| optFarEndType Far-End type of product.
This object is especially relevant for the local optimux.
notApplicable - for devices that don't have a far-end unit. | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.12 |
| optServiceChEnable Service Channel Enable/Disable for each Optimux (local/remote). | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.13 |
| optMaskChAlr Mask Channel Alarm.
This object is applicable only for Optimux cards.
The value of this object is a sum of 2**n, where n is a bit assigned to
a certain Channel. Bit='1' means ma… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.5.1.1.14 |
| optAisEnable AIS enable/disable.
notApplicable - for devices that do not support this feature. | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.15 |
| optFarMng This object is used by Optimux-XL and FomiE3/T3.
Is there possibility of Far-End Management (no/yes).
This object is applicable only for the Local device.
notApplicable - for Remo… | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.16 |
| optClockDivision This object is applicable only for FomiE3/T3 having an HSSI Electrical
interface.
It gives the possibility of Clock Division, so that Clock Rate will
be less than T3/E3.
notApplic… | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.17 |
| optDteLoopEnable DTE Loop enable/disable (for example loop command requested
by router).
This object is applicable only for products having HSSI interface.
notApplicable - for devices that do… | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.18 |
| optGrpClockSourcePrt This object is applicable for Optimux-T3, when optGrpClockSource=localExternal.
It enables the user to select the Channel or Station Clock from which
the Clock is received.
Valid… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.5.1.1.19 |
| optHWVersion HW Version of the device. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.164.3.5.1.1.2 |
| optIncomingAlarm State of the Incoming Alarm (On/Off), via Alarm Relay connector.
This object is applicable only for Optimux-T3. | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.20 |
| optDefChannelSet Default configuration for all Optimux Channels: T1 or E1.
This object is applicable only for Optimux-T3. | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.21 |
| optWaitToRestore This parameter defines the time (sec) device has to wait in the redundant
state until it goes back to the default Link. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.5.1.1.22 |
| optEnforcedLink This parameter is not applicable when optRedundancyCnf = off.
It enables user to enforce a Link in spite of the redundancy mechanism.
Selecting the noEnforcement(2) value cause re… | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.23 |
| optFlipUponEvent This object allows user to define if Flip to the other port will
be performed (or not), for certain possible events.
Each event is represented by a bit. The value of the object is… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.5.1.1.24 |
| optHwMaskChAlr Mask Channel Alarm done by the HW dip-switches.
This object is applicable only for Optimux cards.
The value of this object is a sum of 2**n, where n is a bit assigned to
a certai… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.5.1.1.25 |
| optServiceChExist Service Channel Existence indication for each Optimux (local/remote). | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.26 |
| optMaskSystemAlr Mask all system alarms for each Optimux (local/remote). | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.27 |
| optSWVersion SW Version of the device. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.164.3.5.1.1.3 |
| optPSPrimary The status of the primary Power Supply Unit. | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.4 |
| optPSSecondary The status of the secondary Power Supply Unit. | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.5 |
| optLinkActive This object indicates which link is active.
For Optimux-4 it may be: 5, 6 or 105, 106
For FOMi-E3/T3 it may be: 51, 61 or 151, 161.
For Optimux-T3 it may be: 51 or 61.
For Optimu… | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.164.3.5.1.1.6 |
| optGrpPayLoadLoop Performs payload loop ( remote loop) to 4 E1 channels
at once. | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.8 |
| optGrpClockSource For Optimux XL:
If dsx3TransmitClockSource = localTiming(2), then the user
can configure this field as:
localInternal(2) = use the internal clock of the device
localExternal(3) = … | column | Enumeration | .1.3.6.1.4.1.164.3.5.1.1.9 |