mdlCFanControl

RAD-Dacs-MIB · .1.3.6.1.4.1.164.3.3.2.1.2.1.22

Object

column r/w Enumeration
The desired state of the fan.
              
Module fan control shall manage all fans on the module, if there are more than one.
When mdlCFanControl is 'up', all module's fans must be in on state.
When mdlCFanControl is 'down', all module's fans must be in off state.
              
Setting module mdlCFanControl to 'up' should always succeed (if HW enables detection of
current fan status, the mdlCFanStatus might remain 'down' as a result of a fan failure).
              
up
The desired state for all module's fans is operational.
              
down
The desired state for all module's fans is disabled.

Context

MIB
RAD-Dacs-MIB
OID
.1.3.6.1.4.1.164.3.3.2.1.2.1.22
Type
column
Access
readwrite
Status
current
Parent
mdlCEntry
Table
mdlCTable
Siblings
17

Syntax

Enumeration

Values & Constraints

Enumerated Values
1up
2down

Related Objects

Sibling Objects