inletRCMResidualOperatingCurrent
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.3.3.3.1.14
Object
**NOTE:This object is obsolete. Its functionality was implemented by existing RCM sensor thresholds. The Residual Operating Current (Threshold) for the RCM State sensor. For inlets without an RCM, any attempt to access this OID will return NoSuchInstance error. The value of this OID is in milliamps.
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.3.3.3.1.14- Type
- column
- Access
- readwrite
- Status
- obsolete
- Parent
- inletConfigurationEntry
- Table
- inletConfigurationTable
- Siblings
- 16
Syntax
SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| inletId A unique value for each inlet. Its value ranges between 1 and the
value of inletCount. | column | Integer32 | .1.3.6.1.4.1.13742.6.3.3.3.1.1 |
| inletDeviceCapabilities A bit string indicating which inlet sensors are available. | column | Bits | .1.3.6.1.4.1.13742.6.3.3.3.1.10 |
| inletPoleCapabilities A bit string indicating which inlet pole sensors are available. | column | Bits | .1.3.6.1.4.1.13742.6.3.3.3.1.11 |
| inletPlugDescriptor The inlet plug type as a string. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.13742.6.3.3.3.1.12 |
| inletEnableState Enable/disable PDU operation for this inlet.
When PDU operation is disabled the sensors for this inlet and all
children will no longer be updated, and outlet switching is no longe… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.3.3.3.1.13 |
| inletIsDC Inlet current type: true for DC, false for AC | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.3.3.3.1.15 |
| inletLinePairCount The number of inlet line pairs. | column | Integer32 | .1.3.6.1.4.1.13742.6.3.3.3.1.16 |
| inletLinePairCapabilities A bit string indicating which inlet line pair sensors are available. | column | Bits | .1.3.6.1.4.1.13742.6.3.3.3.1.17 |
| inletLabel The label on the PDU identifying the inlet. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.13742.6.3.3.3.1.2 |
| inletName The user-defined name. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.13742.6.3.3.3.1.3 |
| inletPlug deprecated The type of plug/receptacle wired to the inlet.
Note: PlugTypeEnumeration is no longer updated, unlisted plugs will be
reported as plugOTHER. Use inletPlugDescriptor to reliably d… | column | PlugTypeEnumeration | .1.3.6.1.4.1.13742.6.3.3.3.1.4 |
| inletPoleCount The number of poles.
PDU:
2 for 1-phase circuits
3 for 3-phase delta-wired models
4 for 3-phase wye-wired models, pole 4 is neutral
Power Meter:
2 to 5 depending on the po… | column | Integer32 | .1.3.6.1.4.1.13742.6.3.3.3.1.5 |
| inletRatedVoltage The inlet voltage rating. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.13742.6.3.3.3.1.6 |
| inletRatedCurrent The inlet current rating. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.13742.6.3.3.3.1.7 |
| inletRatedFrequency deprecated The inlet frequency rating.
Deprecated: use pduRatedFrequency for unit nameplate information. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.13742.6.3.3.3.1.8 |
| inletRatedVA deprecated The inlet VA (VoltAmps) rating.
Deprecated: use pduRatedVA for unit nameplate information. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.13742.6.3.3.3.1.9 |