inletDeviceCapabilities
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.3.3.3.1.10
Object
column
Bits
A bit string indicating which inlet sensors are available.
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.3.3.3.1.10- Type
- column
- Access
- readonly
- Status
- current
- Parent
- inletConfigurationEntry
- Table
- inletConfigurationTable
- Siblings
- 16
Syntax
Bits
Values & Constraints
Enumerated Values
0 | rmsCurrent |
1 | peakCurrent |
2 | unbalancedCurrent |
3 | rmsVoltage |
4 | activePower |
5 | apparentPower |
6 | powerFactor |
7 | activeEnergy |
8 | apparentEnergy |
21 | surgeProtectorStatus |
22 | frequency |
23 | phaseAngle |
25 | residualCurrent |
26 | rcmState |
28 | reactivePower |
31 | powerQuality |
34 | displacementPowerFactor |
35 | residualDcCurrent |
50 | crestFactor |
53 | activePowerDemand |
54 | residualAcCurrent |
56 | voltageThd |
57 | currentThd |
59 | unbalancedVoltage |
60 | unbalancedLineLineCurrent |
61 | unbalancedLineLineVoltage |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| inletId A unique value for each inlet. Its value ranges between 1 and the
value of inletCount. | column | Integer32 | .1.3.6.1.4.1.13742.6.3.3.3.1.1 |
| inletPoleCapabilities A bit string indicating which inlet pole sensors are available. | column | Bits | .1.3.6.1.4.1.13742.6.3.3.3.1.11 |
| inletPlugDescriptor The inlet plug type as a string. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.13742.6.3.3.3.1.12 |
| inletEnableState Enable/disable PDU operation for this inlet.
When PDU operation is disabled the sensors for this inlet and all
children will no longer be updated, and outlet switching is no longe… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.3.3.3.1.13 |
| inletRCMResidualOperatingCurrent obsolete **NOTE:This object is obsolete.
Its functionality was implemented by existing RCM sensor thresholds.
The Residual Operating Current (Threshold) for the RCM State sensor.
For inlet… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.3.1.14 |
| inletIsDC Inlet current type: true for DC, false for AC | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.3.3.3.1.15 |
| inletLinePairCount The number of inlet line pairs. | column | Integer32 | .1.3.6.1.4.1.13742.6.3.3.3.1.16 |
| inletLinePairCapabilities A bit string indicating which inlet line pair sensors are available. | column | Bits | .1.3.6.1.4.1.13742.6.3.3.3.1.17 |
| inletLabel The label on the PDU identifying the inlet. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.13742.6.3.3.3.1.2 |
| inletName The user-defined name. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.13742.6.3.3.3.1.3 |
| inletPlug deprecated The type of plug/receptacle wired to the inlet.
Note: PlugTypeEnumeration is no longer updated, unlisted plugs will be
reported as plugOTHER. Use inletPlugDescriptor to reliably d… | column | PlugTypeEnumeration | .1.3.6.1.4.1.13742.6.3.3.3.1.4 |
| inletPoleCount The number of poles.
PDU:
2 for 1-phase circuits
3 for 3-phase delta-wired models
4 for 3-phase wye-wired models, pole 4 is neutral
Power Meter:
2 to 5 depending on the po… | column | Integer32 | .1.3.6.1.4.1.13742.6.3.3.3.1.5 |
| inletRatedVoltage The inlet voltage rating. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.13742.6.3.3.3.1.6 |
| inletRatedCurrent The inlet current rating. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.13742.6.3.3.3.1.7 |
| inletRatedFrequency deprecated The inlet frequency rating.
Deprecated: use pduRatedFrequency for unit nameplate information. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.13742.6.3.3.3.1.8 |
| inletRatedVA deprecated The inlet VA (VoltAmps) rating.
Deprecated: use pduRatedVA for unit nameplate information. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.13742.6.3.3.3.1.9 |