inletPoleSensorLowerWarningThreshold
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.3.3.6.1.22
Object
The lower warning threshold as an unsigned integer. The value of this OID variable should be scaled by inletPoleSensorDecimalDigits. For example, if the value is 1 and inletPoleSensorDecimalDigits is 2, then actual value is 0.01. The value is clamped if the scaled threshold exceeds 4294967295. It is undefined for sensors which can have negative readings. This parameter does not apply to sensors without numerical reading.
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.3.3.6.1.22- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- inletPoleSensorConfigurationEntry
- Table
- inletPoleSensorConfigurationTable
- Siblings
- 21
Syntax
SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| inletPoleIndex A unique value for each inlet pole. Its value
ranges between 1 and the value of inletPoleCount. | column | Integer32 | .1.3.6.1.4.1.13742.6.3.3.6.1.1 |
| inletPoleSensorTolerance deprecated The tolerance: the maximum difference between measurement and the
actual value. The value of this OID variable should be scaled by
(inletPoleSensorDecimalDigits + 1). For example,… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.10 |
| inletPoleSensorMaximum The largest possible reading as an unsigned integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleS… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.11 |
| inletPoleSensorMinimum The smallest possible reading as an unsigned integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPole… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.12 |
| inletPoleSensorHysteresis The hysteresis used when crossing a threshold towards the normal state.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value … | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.13 |
| inletPoleSensorStateChangeDelay The delay measured in samples before a state is asserted.
If the value is zero, then the state is asserted as soon as
it is detected; if it is non-zero, say n, then the assertion
… | column | Unsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.14 |
| inletPoleSensorLowerCriticalThreshold The lower critical threshold as an unsigned integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleS… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.21 |
| inletPoleSensorUpperCriticalThreshold The upper critical threshold as an unsigned integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleS… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.23 |
| inletPoleSensorUpperWarningThreshold The upper warning threshold as an unsigned integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleSe… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.24 |
| inletPoleSensorEnabledThresholds A bit string indicating which thresholds are enabled.
This parameter does not apply to sensors without numerical reading. | column | Bits | .1.3.6.1.4.1.13742.6.3.3.6.1.25 |
| inletPoleSensorSignedMaximum The largest possible reading as a signed integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleSens… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.3.6.1.26 |
| inletPoleSensorSignedMinimum The smallest possible reading as a signed integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleSen… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.3.6.1.27 |
| inletPoleSensorSignedLowerCriticalThreshold The lower critical threshold as a signed integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleSens… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.3.6.1.28 |
| inletPoleSensorSignedLowerWarningThreshold The lower warning threshold as a signed integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleSenso… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.3.6.1.29 |
| inletPoleSensorSignedUpperCriticalThreshold The upper critical threshold as a signed integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleSens… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.3.6.1.30 |
| inletPoleSensorSignedUpperWarningThreshold The upper warning threshold as a signed integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleSenso… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.3.6.1.31 |
| inletPoleSensorLogAvailable Is data logging enabled for this sensor? | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.3.3.6.1.4 |
| inletPoleSensorUnits The unit in which the sensor reading is reported.
This parameter does not apply to sensors without numerical reading. | column | SensorUnitsEnumeration | .1.3.6.1.4.1.13742.6.3.3.6.1.6 |
| inletPoleSensorDecimalDigits The number of digits displayed to the right of the decimal point.
This parameter does not apply to sensors without numerical reading. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.7 |
| inletPoleSensorAccuracy deprecated The accuracy: the maximum relative difference (in percent) between
measurement and the actual value.
This parameter does not apply to sensors without numerical reading. | column | HundredthsOfAPercentage | .1.3.6.1.4.1.13742.6.3.3.6.1.8 |
| inletPoleSensorResolution The resolution: the minimum difference between any two measured values
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value i… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.9 |