inletPoleIndex
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.3.3.6.1.1
Object
column
Integer32
A unique value for each inlet pole. Its value ranges between 1 and the value of inletPoleCount.
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.3.3.6.1.1- Type
- column
- Access
- noaccess
- Status
- current
- Parent
- inletPoleSensorConfigurationEntry
- Table
- inletPoleSensorConfigurationTable
- Siblings
- 21
Syntax
Integer32
Values & Constraints
Object Constraints
range: 1-256
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| inletPoleSensorTolerance deprecated The tolerance: the maximum difference between measurement and the
actual value. The value of this OID variable should be scaled by
(inletPoleSensorDecimalDigits + 1). For example,… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.10 |
| inletPoleSensorMaximum The largest possible reading as an unsigned integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleS… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.11 |
| inletPoleSensorMinimum The smallest possible reading as an unsigned integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPole… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.12 |
| inletPoleSensorHysteresis The hysteresis used when crossing a threshold towards the normal state.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value … | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.13 |
| inletPoleSensorStateChangeDelay The delay measured in samples before a state is asserted.
If the value is zero, then the state is asserted as soon as
it is detected; if it is non-zero, say n, then the assertion
… | column | Unsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.14 |
| inletPoleSensorLowerCriticalThreshold The lower critical threshold as an unsigned integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleS… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.21 |
| inletPoleSensorLowerWarningThreshold The lower warning threshold as an unsigned integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleSe… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.22 |
| inletPoleSensorUpperCriticalThreshold The upper critical threshold as an unsigned integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleS… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.23 |
| inletPoleSensorUpperWarningThreshold The upper warning threshold as an unsigned integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleSe… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.24 |
| inletPoleSensorEnabledThresholds A bit string indicating which thresholds are enabled.
This parameter does not apply to sensors without numerical reading. | column | Bits | .1.3.6.1.4.1.13742.6.3.3.6.1.25 |
| inletPoleSensorSignedMaximum The largest possible reading as a signed integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleSens… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.3.6.1.26 |
| inletPoleSensorSignedMinimum The smallest possible reading as a signed integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleSen… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.3.6.1.27 |
| inletPoleSensorSignedLowerCriticalThreshold The lower critical threshold as a signed integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleSens… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.3.6.1.28 |
| inletPoleSensorSignedLowerWarningThreshold The lower warning threshold as a signed integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleSenso… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.3.6.1.29 |
| inletPoleSensorSignedUpperCriticalThreshold The upper critical threshold as a signed integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleSens… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.3.6.1.30 |
| inletPoleSensorSignedUpperWarningThreshold The upper warning threshold as a signed integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleSenso… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.3.6.1.31 |
| inletPoleSensorLogAvailable Is data logging enabled for this sensor? | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.3.3.6.1.4 |
| inletPoleSensorUnits The unit in which the sensor reading is reported.
This parameter does not apply to sensors without numerical reading. | column | SensorUnitsEnumeration | .1.3.6.1.4.1.13742.6.3.3.6.1.6 |
| inletPoleSensorDecimalDigits The number of digits displayed to the right of the decimal point.
This parameter does not apply to sensors without numerical reading. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.7 |
| inletPoleSensorAccuracy deprecated The accuracy: the maximum relative difference (in percent) between
measurement and the actual value.
This parameter does not apply to sensors without numerical reading. | column | HundredthsOfAPercentage | .1.3.6.1.4.1.13742.6.3.3.6.1.8 |
| inletPoleSensorResolution The resolution: the minimum difference between any two measured values
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value i… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.3.6.1.9 |