ostSynceClockStatus

OMNITRON-EXT-MIB · .1.3.6.1.4.1.7342.7.1.3.1.1.31

Object

column Enumeration
This object indicates the status of the synchronous Ethernet (SyncE)
clock status if synce has been enabled via the ostSynceSource object.
              
Currently this object is applicable to the XM5 only.
              
notApplicable(1)         SyncE is not applicable or not supported on
                         the module
              
internal(2)              SyncE is set to selec the internal free
                         running oscillator
              
linkUpAcquiring(3)       SyncE has been selected and the clock is
                         acquiring lock
              
linkUpLocked(4)          SyncE has acquired lock, but holdover is not
                         valid
              
linkUpLockedHoldover(5)  SyncE has acquired lock and holdover is
                         valid
              
linkDownHoldover(6)      SyncE clock has been lost, but holdover is
                         still valid
              
linkDownFreerun(7)       SyncE clock has been lost and holdover has
                         been lost and the clock is free running
              
linkUpNotLocked (8)      SyncE has detected an extracted clock, but
                         the clock is out of the allowable frequency
                         range

Context

MIB
OMNITRON-EXT-MIB
OID
.1.3.6.1.4.1.7342.7.1.3.1.1.31
Type
column
Access
readonly
Status
current
Parent
ostModuleSettingsEntry
Table
ostModuleSettingsTable
Siblings
36

Syntax

Enumeration

Values & Constraints

Enumerated Values
1notApplicable
2internal
3linkUpAcquiring
4linkUpLocked
5linkUpLockedHoldover
6linkDownHoldover
7linkDownFreerun
8linkUpNotLocked