lgpPwrShutdownLineSwap
LIEBERT-GP-POWER-MIB ·
.1.3.6.1.4.1.476.1.42.3.5.3.17
Object
scalar
Enumeration
The system has previously shutdown due to a condition where the line and neutral were reversed.
Context
- MIB
- LIEBERT-GP-POWER-MIB
- OID
.1.3.6.1.4.1.476.1.42.3.5.3.17- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- lgpPwrStatus
- Siblings
- 57
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | yes |
2 | no |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| lgpPwrTransferCount Number of times that the output load has been transferred between the
available input sources. | scalar | Count SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.3.1 |
| lgpPwrOutputToLoadOnBypass The present source of output power is the Bypass. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.10 |
| lgpPwrBoost The present state of the boost circuitry | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.11 |
| lgpPwrBuck The present state of the buck circuitry | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.12 |
| lgpPwrShutdownOverTemperature The system has previously shutdown due to an over temperature
condition. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.13 |
| lgpPwrShutdownOverload The system has previously shutdown due to an over load condition. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.14 |
| lgpPwrShutdownDcBusOverload The system has previously shutdown due to a DC bus over load
condition. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.15 |
| lgpPwrShutdownOutputShort The system has previously shutdown due to an output short condition. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.16 |
| lgpPwrShutdownLowBattery The system has previously shutdown due to a low battery condition. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.18 |
| lgpPwrShutdownRemote The system has previously shutdown due to a remote shutdown command. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.19 |
| lgpPwrAutoTransferTimer The required wait time between output load auto transfer attempts
between available input sources. | scalar | seconds SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.3.2 |
| lgpPwrShutdownInputUnderVoltage The system has previously shutdown due to an under voltage condition
during startup. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.20 |
| lgpPwrShutdownPowerFactorCorrectionFailure The system has previously shutdown due to a power factor correction
startup failure. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.21 |
| lgpPwrShutdownHardware The system has previously shutdown due external shutdown signal. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.22 |
| lgpPwrRedundantSubModule The system has a redundant battery module installed. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.23 |
| lgpPwrBypassReady The ability of the bypass to support the output load of the system.
If Yes, the bypass is available to transfer to. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.24 |
| lgpPwrGeneratorStatus The state of the system generator. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.25 |
| lgpPwrRotaryBreakerStatus The state of the system rotary breaker. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.26 |
| lgpPwrPowerFactorCorrection The state of the power factor correction circuitry of the system. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.27 |
| lgpPwrBypassSyncDiff The phase angle difference between the inverter output and bypass
source. A positive value means the inverter leads the bypass source.
A negative value means the inverter lags the… | scalar | 0.1 Degrees SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.3.28 |
| lgpPwrBypassOverloadShutdownTime The calculated time remaining before bypass static switch shutdown due
to the present overload condition. If the bypass is not in an overload
condition, this object returns -1. | scalar | seconds SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.3.29 |
| lgpPwrAutoReTransferEnabled The ability to retransfer the output load automatically to the well
known measurement source from the 'lgpPwrWellKnownMeasurements'
sub-tree that is the preferred input source of … | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.3 |
| lgpPwrInverterOverloadShutdownTime The calculated time remaining before inverter shutdown. The calculated
time of inverter operation remaining for the present overload event.
Note: If the inverter is not… | scalar | seconds SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.3.30 |
| lgpPwrStateOutputSource The UPS's output power source (inverter, bypass, or none).
NOTE: It is possible that the load still has power from the
Maintenance Bypass. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.31 |
| lgpPwrStateInputSource The system input power source (none, utility, generator). | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.32 |
| lgpPwrStateInputQualification The current state of the system input. The unit may or may not operate
normally under 'marginalLow' and 'marginalHigh' states. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.33 |
| lgpPwrStateBypassStaticSwitchState The current state of the bypass static switch. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.34 |
| lgpPwrStateBypassQualification The current operational state of the bypass static switch. The unit may
or may not operate normally under 'marginalLow' and 'marginalHigh'
states. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.35 |
| lgpPwrStateDCBusQualification The current operational state of the DC bus. The unit may or may not
operate normally under 'marginalLow' and 'marginalHigh' states. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.36 |
| lgpPwrStateOutQualification The current operational state of the output. The unit may or may not
operate normally under 'marginalLow' and 'marginalHigh' states. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.37 |
| lgpPwrStateInverterQualification The current operational state of the inverter. The unit may or may not
operate normally under 'marginalLow' and 'marginalHigh' states. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.38 |
| lgpPwrStateInverterState The current state of the inverter. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.39 |
| lgpPwrSyncPhaseAngle The phase angle difference of source 1 in relation to source 2. | scalar | 0.1 Degrees Integer32 | .1.3.6.1.4.1.476.1.42.3.5.3.4 |
| lgpPwrStateRectifierState The current state of the rectifier. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.40 |
| lgpPwrStateModuleGroup This group contains UPS module information. | node | - | .1.3.6.1.4.1.476.1.42.3.5.3.41 |
| lgpPwrStateBackfeedBrkrState The state of the Static Bypass Switch Line Disconnect Breaker. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.42 |
| lgpPwrStateLoadDisconnectState The state of the Static Bypass Switch Load Disconnect Breaker. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.43 |
| lgpPwrStateInputBrkrState The state of the Input Disconnect Breaker. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.44 |
| lgpPwrStateTrapFilterBrkrState The state of the Trap Filter Disconnect Breaker. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.45 |
| lgpPwrStateInvOutputBrkrState The state of the Inverter Output Disconnect Breaker. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.46 |
| lgpPwrStateIntBypassBrkrState The state of the Internal Bypass Breaker. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.47 |
| lgpPwrStateBypassIsolBrkrState The state of the Bypass Isolation Breaker. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.48 |
| lgpPwrStateRectifierIsolBrkrState The state of the Rectifier Isolation Breaker. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.49 |
| lgpPwrParallelSystemOutputToLoadSource The source supporting the parallel system's load. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.5 |
| lgpPwrStateMaintBypassBrkrState The state of the Maintenance Bypass Breaker. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.50 |
| lgpPwrStateMaintIsolBrkrState The state of the Maintenance Isolation Breaker. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.51 |
| lgpPwrStateOutStaticSwState The state of the Output Series Static Switch. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.52 |
| lgpPwrStateModuleOutBrkrState The state of the Module Output Breaker. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.53 |
| lgpPwrBypassReXfrRemainTime The time remaining before an inverter overload or inverter fault can
be cleared and auto retransfer from the bypass to the inverter can take
place.
Note: If an inver… | scalar | seconds SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.3.54 |
| lgpPwrStateUpsOutputSource The present source of output power. The enumeration
none(2) indicates that there is no source of output
power (and therefore no output power), for example,
the system has opened … | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.55 |
| lgpPwrStateLoadBusSynchronization The state of the Load Bus Synchronizer (LBS). | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.56 |
| lgpPwrStateCircuitBrkrStateGroup This group contains Static Switch circuit breaker state information. | node | - | .1.3.6.1.4.1.476.1.42.3.5.3.57 |
| lgpPwrEconomicOperation The present state of ECO mode operation,
on(1) if system is on bypass due to ECO mode operation,
off(0) any other time. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.58 |
| lgpPwrDcToDcConverter The state of the DC to DC converter. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.6 |
| lgpPwrOutputToLoadOnInverter The present source of output power is the Inverter. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.7 |
| lgpPwrBatteryChargeCompensating The system is adjusting the battery charging algorithm to accommodate
for the battery temperature. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.8 |
| lgpPwrInverterReady The ability of the inverter to support the output load of the system. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.3.9 |