lgpEnvConfigTempControlAlgorithm
LIEBERT-GP-ENVIRONMENTAL-MIB ·
.1.3.6.1.4.1.476.1.42.3.4.4.33
Object
scalar
r/w
Enumeration
Selects the algorithm for controlling temperature.
Context
- MIB
- LIEBERT-GP-ENVIRONMENTAL-MIB
- OID
.1.3.6.1.4.1.476.1.42.3.4.4.33- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- lgpEnvConfig
- Siblings
- 41
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | pi |
2 | pid |
3 | intelligent |
4 | proportional |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| lgpEnvConfigReheatLockout If locked-out the reheats will not operate even if controller calls
for its operation. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.1 |
| lgpEnvConfigFilterServiceInterval The amount of time, in hours, between scheduled maintenance
of the system filter. When the filter service timer reaches this
value an lgpConditionChangeFilter will be activated. … | scalar | hours SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.4.4.10 |
| lgpEnvConfigSleepModeDeadbandRangeDegC The allowable deviation above and below the temperature set point used
to create a no control region, a dead-band, where heating and
cooling control are disabled. This dead-ban… | scalar | .1 degrees Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.11 |
| lgpEnvConfigSleepModeDeadbandRangeDegF The allowable deviation above and below the temperature set point used
to create a no control region, a dead-band, where heating and
cooling control are disabled. This dead-ban… | scalar | .1 degrees Fahrenheit SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.12 |
| lgpEnvConfigSupplyTempLowLimitDegF The minimum allowable supply temperature. | scalar | degrees Fahrenheit SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.13 |
| lgpEnvConfigSupplyTempLowLimitDegC The minimum allowable supply temperature. | scalar | degrees Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.14 |
| lgpEnvConfigTemperatureIntegTime The value used as the integration factor in the proportional
integral derivative (PID) temperature calculation. | scalar | minutes SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.15 |
| lgpEnvConfigLocalTemperatureUnit The local temperature unit of the system. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.16 |
| lgpEnvConfigSleepMode The configured mode of the device's sleep function. If 'enabled',
the device will sleep, or not operate, for each 'lgpEnvSleepDay' that
is enabled and also during the periods def… | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.17 |
| lgpEnvConfigHumidityIntegTime The value used as the integration factor in the proportional
integral derivative (PID) humidity calculation. | scalar | minutes SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.18 |
| lgpEnvConfigFreecoolingDeltaDegF The minimum temperature differential between the control
temperature measurement and the coolant required to utilize
free-cooling. | scalar | degrees Fahrenheit SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.19 |
| lgpEnvConfigHumLockout If locked-out the humidifier will not operate even if controller
calls for its operation. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.2 |
| lgpEnvConfigFreecoolingDeltaDegC The minimum temperature differential between the control
temperature measurement and the coolant required to utilize
free-cooling. | scalar | degrees Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.20 |
| lgpEnvConfigSupplyTempLowLimit The system configuration parameter to enable or disable the supply
air low temperature limit. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.21 |
| lgpEnvConfigSensorEventsStandard The system configuration parameter to enable or disable the standard
sensor events. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.22 |
| lgpEnvConfigSensorEvents1 The system configuration parameter to enable or disable sensor 1 events. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.23 |
| lgpEnvConfigSleepModeDeadbandRange The system configuration parameter to enable or disable the use of
the sleep interval dead-band range in the sleep mode temperature
calculations and control algorithm. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.24 |
| lgpEnvConfigAutoConfiguration The system configuration parameter to enable or disable the auto
configuration feature. This feature configures temperature and
humidity control parameters. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.25 |
| lgpEnvConfigDeltaGlycolType The system configuration parameter that specifies how the system
will determine if there is enough capacity to initiate free
cooling. If 'disabled', the system will use the valve … | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.26 |
| lgpEnvConfigChillWaterControl The system configuration parameter to enable or disable the minimum
chill water temperature control. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.27 |
| lgpEnvConfigInfaredFlushRate The Infrared humidifier pan overfill rate. This parameter configures
the amount of water that flows into the humidifier pan when the
'humidifier is in operation. | scalar | percent SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.4.4.28 |
| lgpEnvConfigHumidityControl The present configured state of the automatic humidity compensation
algorithm. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.29 |
| lgpEnvConfigCompressorLockout The system as locked out the compressor(s). If locked-out, the
compressor(s) will not operate even if the controller calls for their
operation. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.30 |
| lgpEnvConfigReheatAndHumidifierLockout The system as locked out the compressor(s). If locked-out, the
electrical reheats and humidifier will not operate even if the
controller calls for their operation. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.31 |
| lgpEnvOperationalTimeTable A list of environmental operational time ranges for a given
environmental unit. The entries in this table may be duplicated from
values in the 'lgpEnvStatistics' group.
… | table | - | .1.3.6.1.4.1.476.1.42.3.4.4.32 |
| lgpEnvConfigFanSpeedMode Changes the function of the fan speed output. If auto, then the fan
speed is modulated. If manual, the fan speed output follows
lgpEnvConfigFanSpeedCapacity. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.34 |
| lgpEnvConfigFanSpeedCapacity Sets the fan speed output if lgpEnvConfigFanSpeedMode is set to
'manual'. Typical values range from 0 to 100% (actual valid ranges may
differ from unit to unit). | scalar | percent SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.4.4.35 |
| lgpEnvConfigBmsResetTimer The current count-down time for a BMS to continue controlling the fan
speed. If this value reaches 0, then the condition
lgpConditionBmsResetTimerExpired will be generated. If a… | scalar | minutes SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.4.4.36 |
| lgpEnvConfigDisableSensorOffsetDegC If any of the enclosure temperature sensors
(lgpEnvEnclosureTemperatureSensors) are outside the average reading by
this amount, that sensor's readings will not be used. | scalar | degrees Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.37 |
| lgpEnvConfigDisableSensorOffsetDegF If any of the enclosure temperature sensors
(lgpEnvEnclosureTemperatureSensors) are outside the average reading by
this amount, that sensor's readings will not be used. | scalar | degrees Fahrenheit SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.38 |
| lgpEnvConfigCabinetSensorAlarms Enable or Disable Cabinet Sensor Alarms. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.39 |
| lgpEnvConfigRestartDelay When utility power is disrupted, this is the delay interval to wait
before restarting the system after the utility power is restored.
A Restart Delay of zero denotes a manual rest… | scalar | seconds SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.4.4.4 |
| lgpEnvConfigAirTemperatureControlSensor Sensor from which air temperature measurements will be used for
cooling and heating control. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.42 |
| lgpEnvConfigFanSpeedControlSensor Sensor from which air temperature measurements will be used for fan
speed control. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.43 |
| lgpEnvConfigMinFanSpeed Sets the minimum fan speed output if lgpEnvConfigFanSpeedMode is set
to 'Auto'. | scalar | percent SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.4.4.44 |
| lgpEnvConfigMaxFanSpeed Sets the maximum fan speed output if lgpEnvConfigFanSpeedMode is set
to 'Auto'. | scalar | percent SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.4.4.45 |
| lgpEnvConfigFanSpeedPropBandDegC Temperature control band above the temperature set point calculated
for proportional fan speed control. If measured air temperature is
within this band, fan speed operations are … | scalar | degrees Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.46 |
| lgpEnvConfigFanSpeedPropBandDegF Temperature control band above the temperature set point calculated
for proportional fan speed control. If measured air temperature is
within this band, fan speed operations are … | scalar | degrees Fahrenheit SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.47 |
| lgpEnvConfigRemoteShutdown When in the disabled state, the remote shutdown feature should
be locked out. The enabled state is self-describing. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.7 |
| lgpEnvConfigCoolingServiceInterval The amount of time, in hours, between scheduled maintenance
of the cooling system. When the cooling service timer reaches
this value an lgpConditionServiceCooling will be activat… | scalar | hours SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.4.4.8 |
| lgpEnvConfigHumidifierServiceInterval The amount of time, in hours, between scheduled maintenance
of the humidifier. When the humidifier service timer reaches
this value an lgpConditionServiceHumidifier will be activ… | scalar | hours SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.4.4.9 |