lgpEnvConfigFilterServiceInterval
LIEBERT-GP-ENVIRONMENTAL-MIB ·
.1.3.6.1.4.1.476.1.42.3.4.4.10
Object
The amount of time, in hours, between scheduled maintenance of the system filter. When the filter service timer reaches this value an lgpConditionChangeFilter will be activated. Once service has been completed the filter service timer should be reset to 0.
Context
- MIB
- LIEBERT-GP-ENVIRONMENTAL-MIB
- OID
.1.3.6.1.4.1.476.1.42.3.4.4.10- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- hours
- Parent
- lgpEnvConfig
- Siblings
- 41
Syntax
hours SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| lgpEnvConfigReheatLockout If locked-out the reheats will not operate even if controller calls
for its operation. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.1 |
| lgpEnvConfigSleepModeDeadbandRangeDegC The allowable deviation above and below the temperature set point used
to create a no control region, a dead-band, where heating and
cooling control are disabled. This dead-ban… | scalar | .1 degrees Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.11 |
| lgpEnvConfigSleepModeDeadbandRangeDegF The allowable deviation above and below the temperature set point used
to create a no control region, a dead-band, where heating and
cooling control are disabled. This dead-ban… | scalar | .1 degrees Fahrenheit SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.12 |
| lgpEnvConfigSupplyTempLowLimitDegF The minimum allowable supply temperature. | scalar | degrees Fahrenheit SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.13 |
| lgpEnvConfigSupplyTempLowLimitDegC The minimum allowable supply temperature. | scalar | degrees Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.14 |
| lgpEnvConfigTemperatureIntegTime The value used as the integration factor in the proportional
integral derivative (PID) temperature calculation. | scalar | minutes SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.15 |
| lgpEnvConfigLocalTemperatureUnit The local temperature unit of the system. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.16 |
| lgpEnvConfigSleepMode The configured mode of the device's sleep function. If 'enabled',
the device will sleep, or not operate, for each 'lgpEnvSleepDay' that
is enabled and also during the periods def… | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.17 |
| lgpEnvConfigHumidityIntegTime The value used as the integration factor in the proportional
integral derivative (PID) humidity calculation. | scalar | minutes SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.18 |
| lgpEnvConfigFreecoolingDeltaDegF The minimum temperature differential between the control
temperature measurement and the coolant required to utilize
free-cooling. | scalar | degrees Fahrenheit SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.19 |
| lgpEnvConfigHumLockout If locked-out the humidifier will not operate even if controller
calls for its operation. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.2 |
| lgpEnvConfigFreecoolingDeltaDegC The minimum temperature differential between the control
temperature measurement and the coolant required to utilize
free-cooling. | scalar | degrees Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.20 |
| lgpEnvConfigSupplyTempLowLimit The system configuration parameter to enable or disable the supply
air low temperature limit. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.21 |
| lgpEnvConfigSensorEventsStandard The system configuration parameter to enable or disable the standard
sensor events. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.22 |
| lgpEnvConfigSensorEvents1 The system configuration parameter to enable or disable sensor 1 events. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.23 |
| lgpEnvConfigSleepModeDeadbandRange The system configuration parameter to enable or disable the use of
the sleep interval dead-band range in the sleep mode temperature
calculations and control algorithm. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.24 |
| lgpEnvConfigAutoConfiguration The system configuration parameter to enable or disable the auto
configuration feature. This feature configures temperature and
humidity control parameters. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.25 |
| lgpEnvConfigDeltaGlycolType The system configuration parameter that specifies how the system
will determine if there is enough capacity to initiate free
cooling. If 'disabled', the system will use the valve … | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.26 |
| lgpEnvConfigChillWaterControl The system configuration parameter to enable or disable the minimum
chill water temperature control. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.27 |
| lgpEnvConfigInfaredFlushRate The Infrared humidifier pan overfill rate. This parameter configures
the amount of water that flows into the humidifier pan when the
'humidifier is in operation. | scalar | percent SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.4.4.28 |
| lgpEnvConfigHumidityControl The present configured state of the automatic humidity compensation
algorithm. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.29 |
| lgpEnvConfigCompressorLockout The system as locked out the compressor(s). If locked-out, the
compressor(s) will not operate even if the controller calls for their
operation. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.30 |
| lgpEnvConfigReheatAndHumidifierLockout The system as locked out the compressor(s). If locked-out, the
electrical reheats and humidifier will not operate even if the
controller calls for their operation. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.31 |
| lgpEnvOperationalTimeTable A list of environmental operational time ranges for a given
environmental unit. The entries in this table may be duplicated from
values in the 'lgpEnvStatistics' group.
… | table | - | .1.3.6.1.4.1.476.1.42.3.4.4.32 |
| lgpEnvConfigTempControlAlgorithm Selects the algorithm for controlling temperature. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.33 |
| lgpEnvConfigFanSpeedMode Changes the function of the fan speed output. If auto, then the fan
speed is modulated. If manual, the fan speed output follows
lgpEnvConfigFanSpeedCapacity. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.34 |
| lgpEnvConfigFanSpeedCapacity Sets the fan speed output if lgpEnvConfigFanSpeedMode is set to
'manual'. Typical values range from 0 to 100% (actual valid ranges may
differ from unit to unit). | scalar | percent SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.4.4.35 |
| lgpEnvConfigBmsResetTimer The current count-down time for a BMS to continue controlling the fan
speed. If this value reaches 0, then the condition
lgpConditionBmsResetTimerExpired will be generated. If a… | scalar | minutes SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.4.4.36 |
| lgpEnvConfigDisableSensorOffsetDegC If any of the enclosure temperature sensors
(lgpEnvEnclosureTemperatureSensors) are outside the average reading by
this amount, that sensor's readings will not be used. | scalar | degrees Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.37 |
| lgpEnvConfigDisableSensorOffsetDegF If any of the enclosure temperature sensors
(lgpEnvEnclosureTemperatureSensors) are outside the average reading by
this amount, that sensor's readings will not be used. | scalar | degrees Fahrenheit SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.38 |
| lgpEnvConfigCabinetSensorAlarms Enable or Disable Cabinet Sensor Alarms. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.39 |
| lgpEnvConfigRestartDelay When utility power is disrupted, this is the delay interval to wait
before restarting the system after the utility power is restored.
A Restart Delay of zero denotes a manual rest… | scalar | seconds SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.4.4.4 |
| lgpEnvConfigAirTemperatureControlSensor Sensor from which air temperature measurements will be used for
cooling and heating control. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.42 |
| lgpEnvConfigFanSpeedControlSensor Sensor from which air temperature measurements will be used for fan
speed control. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.43 |
| lgpEnvConfigMinFanSpeed Sets the minimum fan speed output if lgpEnvConfigFanSpeedMode is set
to 'Auto'. | scalar | percent SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.4.4.44 |
| lgpEnvConfigMaxFanSpeed Sets the maximum fan speed output if lgpEnvConfigFanSpeedMode is set
to 'Auto'. | scalar | percent SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.4.4.45 |
| lgpEnvConfigFanSpeedPropBandDegC Temperature control band above the temperature set point calculated
for proportional fan speed control. If measured air temperature is
within this band, fan speed operations are … | scalar | degrees Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.46 |
| lgpEnvConfigFanSpeedPropBandDegF Temperature control band above the temperature set point calculated
for proportional fan speed control. If measured air temperature is
within this band, fan speed operations are … | scalar | degrees Fahrenheit SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.4.47 |
| lgpEnvConfigRemoteShutdown When in the disabled state, the remote shutdown feature should
be locked out. The enabled state is self-describing. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.4.4.7 |
| lgpEnvConfigCoolingServiceInterval The amount of time, in hours, between scheduled maintenance
of the cooling system. When the cooling service timer reaches
this value an lgpConditionServiceCooling will be activat… | scalar | hours SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.4.4.8 |
| lgpEnvConfigHumidifierServiceInterval The amount of time, in hours, between scheduled maintenance
of the humidifier. When the humidifier service timer reaches
this value an lgpConditionServiceHumidifier will be activ… | scalar | hours SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.4.4.9 |