lldpV2Xdot3LocPowerPairControlable
IEEE8023-DOT3-LLDP-EXT-V2-MIB ·
.1.3.111.2.802.3.1.5.1.2.2.1.4
Object
column
SNMPv2-TCTruthValue
The truth value is derived from the value of pethPsePortPowerPairsControlAbility object (defined in Clause 8) and is used to indicate whether the pair selection can be controlled on the given port associated with the local system.
Context
- MIB
- IEEE8023-DOT3-LLDP-EXT-V2-MIB
- OID
.1.3.111.2.802.3.1.5.1.2.2.1.4- Type
- column
- Access
- readonly
- Status
- current
- Parent
- lldpV2Xdot3LocPowerEntry
- Table
- lldpV2Xdot3LocPowerTable
- Siblings
- 13
Values & Constraints
Type Values
1 | true |
2 | false |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| lldpV2Xdot3LocPowerPortClass The value that identifies the port Class of the given port
associated with the local system. | column | LLDP-V2-TC-MIBLldpV2PowerPortClass | .1.3.111.2.802.3.1.5.1.2.2.1.1 |
| lldpV2Xdot3LocPDRequestedPowerValue A GET returns the PD requested power value.
For a PD, it is the power value that the PD has currently
requested from the remote system. PD requested power value
is the maximum inp… | column | SNMPv2-SMIInteger32 | .1.3.111.2.802.3.1.5.1.2.2.1.10 |
| lldpV2Xdot3LocPSEAllocatedPowerValue A GET returns the PSE allocated power value.
For a PSE, it is the power value that the PSE has currently
allocated to the remote system. The PSE allocated power value
is the maxim… | column | SNMPv2-SMIInteger32 | .1.3.111.2.802.3.1.5.1.2.2.1.11 |
| lldpV2Xdot3LocResponseTime A GET returns the response time in seconds of the local system.
For a PD, it is the maximum time required to update the value of
lldpV2Xdot3LocPDRequestedPowerValue when the remot… | column | SNMPv2-SMIInteger32 | .1.3.111.2.802.3.1.5.1.2.2.1.12 |
| lldpV2Xdot3LocReady The truth value used to identify whether the local Data Link Layer
classification engine has completed initialization and is ready to
receive and transmit LLDPDUs. | column | SNMPv2-TCTruthValue | .1.3.111.2.802.3.1.5.1.2.2.1.13 |
| lldpV2Xdot3LocReducedOperationPowerValue A GET returns the reduced operation power value. For a PD, it
is a power value that is lower than the currently requested
power value. This reduced operation power value represent… | column | SNMPv2-SMIInteger32 | .1.3.111.2.802.3.1.5.1.2.2.1.14 |
| lldpV2Xdot3LocPowerMDISupported The truth value used to indicate whether the MDI power is
supported on the given port associated with the local system. | column | SNMPv2-TCTruthValue | .1.3.111.2.802.3.1.5.1.2.2.1.2 |
| lldpV2Xdot3LocPowerMDIEnabled The truth value used to identify whether MDI power is
enabled on the given port associated with the local system. | column | SNMPv2-TCTruthValue | .1.3.111.2.802.3.1.5.1.2.2.1.3 |
| lldpV2Xdot3LocPowerPairs This object contains the value of the pethPsePortPowerPairs
object (defined in Clause 8) which is associated with
the given port on the local system. | column | Unsigned32 | .1.3.111.2.802.3.1.5.1.2.2.1.5 |
| lldpV2Xdot3LocPowerClass This object contains the value of the
pethPsePortPowerClassifications object (defined in
Clause 8) which is associated with the given port on the
local system. | column | Unsigned32 | .1.3.111.2.802.3.1.5.1.2.2.1.6 |
| lldpV2Xdot3LocPowerType A GET returns an integer indicating whether the local
system is a PSE or a PD and whether it is Type 1 or Type 2. | column | Enumeration | .1.3.111.2.802.3.1.5.1.2.2.1.7 |
| lldpV2Xdot3LocPowerSource A GET returns an integer indicating the power sources of the
local system. A PSE indicates whether it is being powered by
a primary power source; a backup power source; or unknown… | column | Enumeration | .1.3.111.2.802.3.1.5.1.2.2.1.8 |
| lldpV2Xdot3LocPowerPriority A GET returns the priority of a PD system. For a PSE, this
is the priority that the PSE assigns to the PD. For a PD, this
is the priority that the PD requests from the PSE. A SET
… | column | Enumeration | .1.3.111.2.802.3.1.5.1.2.2.1.9 |