hwEventAdminStatus

HUAWEI-SNMP-NOTIFICATION-MIB · .1.3.6.1.4.1.2011.6.30.6.1.1.9

Object

column r/w Enumeration
Event management status. Currently, the system supports two states.
Options:
1. init(1)       -During the setting operation, you can change only the event that is
                  in the initial state to the alarm but cannot change an alarm to an event. 
                  Therefore, init(1) can be implemented only through the getting operation 
                  to check whether the current state is initial. 
2. conversion(2) -If an event needs to be converted into an alarm, 
                  perform the setting operation through conversion(2).

Context

MIB
HUAWEI-SNMP-NOTIFICATION-MIB
OID
.1.3.6.1.4.1.2011.6.30.6.1.1.9
Type
column
Access
readwrite
Status
current
Parent
hwEventCtrlEntry
Table
hwEventCtrlTable
Siblings
9

Syntax

Enumeration

Values & Constraints

Enumerated Values
1init
2conversion

Related Objects