hwLoopLineTestSysConfigSigCapUpperLimit
HUAWEI-COMMTEST-MIB ·
.1.3.6.1.4.1.2011.6.21.1.1.1.9.3
Object
scalar
r/w
Unsigned32
The three parameters(capacitance's upper-limit value, lower-limit value and resistance value) are used to determine the signature's existence. The capacitance ranges from 50nF to 2500nF, default: 1350nF. The capacitance's upper-limit value >= the capacitance's lower-limit value.
Context
- MIB
- HUAWEI-COMMTEST-MIB
- OID
.1.3.6.1.4.1.2011.6.21.1.1.1.9.3- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- hwLoopLineTestSysConfigPara
- Siblings
- 4
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 50-2500
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwLoopLineTestSysConfigConvertAB Indicates the polarity of A wire and B wire.
Options:
1. normal(1) -default polarity of A wire and B wire
2. reverse(2) -reverse polarity of A wire and B wire
3. invalid(-1) -… | scalar | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.9.1 |
| hwLoopLineTestSysConfigCableFactor The cable-factor used to detect significant terminal device capacitance.
The cable-factor ranges from 1 to 1000 units of 0.001
(Physical values are 0.001 to 1, default: 0.083). | scalar | Unsigned32 | .1.3.6.1.4.1.2011.6.21.1.1.1.9.2 |
| hwLoopLineTestSysConfigSigCapLowerLimit The three parameters(capacitance's upper-limit value, lower-limit value and resistance value) are used to determine the signature's existence.
The capacitance ranges from 50nF to … | scalar | Unsigned32 | .1.3.6.1.4.1.2011.6.21.1.1.1.9.4 |
| hwLoopLineTestSysConfigSigResistance The three parameters(capacitance's upper-limit value, lower-limit value and resistance value) are used to determine the signature's existence.
The resistance ranges from 10000ohm … | scalar | Unsigned32 | .1.3.6.1.4.1.2011.6.21.1.1.1.9.5 |