hwLoopLineTestSysConfigSigCapLowerLimit

HUAWEI-COMMTEST-MIB · .1.3.6.1.4.1.2011.6.21.1.1.1.9.4

Object

scalar r/w Unsigned32
The three parameters(capacitance's upper-limit value, lower-limit value and resistance value) are used to determine the signature's existence.
The capacitance ranges from 50nF to 2500nF, default: 250nF.
The capacitance's upper-limit value >= the capacitance's lower-limit value.

Context

MIB
HUAWEI-COMMTEST-MIB
OID
.1.3.6.1.4.1.2011.6.21.1.1.1.9.4
Type
scalar
Access
readwrite
Status
current
Parent
hwLoopLineTestSysConfigPara
Siblings
4

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 50-2500