hwClkInQL
HUAWEI-CLK-MIB ·
.1.3.6.1.4.1.2011.6.25.1.1.1.8
Object
column
r/w
Enumeration
Clock source quality level:
Options:
1. qlPRC(2) - indicates that primary reference clock
2. qlSsuA(4) - indicates that the clock signal comes from class I or class
V sub-clock prescribed on G.812 protocol
3. qlSsuB(8) - indicates that the clock signal comes from class VI sub-clock
prescribed on G.812 protocol
4. qlSEC(11) - indicates that the clock signal comes from SEC(SDH Equipment
Clock) prescribed on G.813 protocol
5. qlDNU(15) - indicates that the clock signal can't be used for synchronization
6. qlCLEAR(255) - indicates that it is a wrong clock quality level
Context
- MIB
- HUAWEI-CLK-MIB
- OID
.1.3.6.1.4.1.2011.6.25.1.1.1.8- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hwClockInManageEntry
- Table
- hwClockInManageTable
- Siblings
- 11
Syntax
Enumeration
Values & Constraints
Enumerated Values
2 | qlPRC |
4 | qlSsuA |
8 | qlSsuB |
11 | qlSEC |
15 | qlDNU |
255 | qlCLEAR |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwClkInIndex Clock source index: ranging from 0 to 9. The value 255 indicates the local
clock source.
Range: 0-9 | 255 | column | Integer32 | .1.3.6.1.4.1.2011.6.25.1.1.1.1 |
| hwClkInClearFaultRecord Clear fault record of one clock source.
Options:
1.clearFaultRecord(1) -Clears fault records | column | Enumeration | .1.3.6.1.4.1.2011.6.25.1.1.1.10 |
| hwClkLockState Clock lock state.
Options:
1.locked(1) - indicates that the clock is locked
2.unlocked(2) - indicates that the clock is unlocked | column | Enumeration | .1.3.6.1.4.1.2011.6.25.1.1.1.11 |
| hwClkFreqDeviation Clock source freq-deviation-value
The value is ten times of actual frequency deviation value
Unit: 0.1ppm
The invalid value is 0x7fffffff | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.25.1.1.1.12 |
| hwClkInPostion The ifIndex of physical position of clock source. If the clock source
isn't a sysline clock, the value will be 0xFFFFFFFFFFFFFF.
The first byte indicates the NO. of CESoP index.
T… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.25.1.1.1.2 |
| hwClkInWorkMode Clock source type.
Includes the line clock source, BITS clock source, and local surge source.
If it is line clock source of a CES port, the clock source type may be CES line or C… | column | Enumeration | .1.3.6.1.4.1.2011.6.25.1.1.1.3 |
| hwClkInOperStatus Clock source state.
Options:
1.none(1) - indicates that the clock source index isn't configured
2.normal(2) - indicates that the state of the clock source is active
3.… | column | Enumeration | .1.3.6.1.4.1.2011.6.25.1.1.1.4 |
| hwClkInRowStatus Clock Source operation:
A user can add a clock source or clear a clock source.
After a user adds a clock source,the clock works in trace mode.
After a user clears a clock source, … | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.2011.6.25.1.1.1.5 |
| hwClkInBitsImpedance BITS clock impedance type.The impedance value must be set when the clock source is a bits clock.
Options:
1. bitsImpedance75ohm(1) - indicates that the impedance of this BI… | column | Enumeration | .1.3.6.1.4.1.2011.6.25.1.1.1.6 |
| hwClkInBitsType BITS clock type:
Options:
1.bitsType2MHz(1) - indicates that the BITS clock type is 2MHz
2.bitsType2Mbps(2) - indicates that the BITS clock type is 2bps
3.bitsType64K… | column | Enumeration | .1.3.6.1.4.1.2011.6.25.1.1.1.7 |
| hwClkInFaultRecord Clock source fault record.
Options:
1.noFaultRecord(1) - indicates that there is no fault record
2.faultRecord(2) - indicates that the clock source had a fault record | column | Enumeration | .1.3.6.1.4.1.2011.6.25.1.1.1.9 |