eriAlarmIndeterminate
ERICSSON-ALARM-MIB ·
.1.3.6.1.4.1.193.183.4.2.0.1
Object
notification
This notification is sent when a resource
detects a new alarm state with severity
indeterminate. The notification is also used to
change severity and/or additional text of an
alarm. The combination of ManagedObject and
MajorType/MinorType is always unique and can be
used by management systems to correlate alarm,
alarm change, and alarm clear. A corresponding
row will be created in the Alarm Table. The
sequence number will increase for every
notification and can be used to detect lost
notifications.
A management system should be prepared for
appending text to additional text, indicated by
the eriAlarmNObjMoreAdditionalText varbind, and
sent with eriAlarmAppendInfo. (Note do not
confuse this with a change of additional text.)
A management system should also be prepared to
receive a resource ID (OID) identifying the
alarming resource if the system sending the
notification can provide that information. In
that case, eriAlarmNObjResourceId will be set to
'true' and the resource ID will be sent in an
eriAlarmAppendInfo notification.
Context
- MIB
- ERICSSON-ALARM-MIB
- OID
.1.3.6.1.4.1.193.183.4.2.0.1- Type
- notification
- Status
- current
- Parent
- eriAlarmNotifsPrefix
- Siblings
- 14
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eriAlarmIndAlert This notification is sent when a resource
detects a new alert with severity indeterminate.
A corresponding row will be created in the Alert
Table. The sequence number will increas… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.10 |
| eriAlarmWarnAlert This notification is sent when a resource
detects a new alert with severity warning. A
corresponding row will be created in the Alert
Table. The sequence number will increase for
… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.11 |
| eriAlarmMinorAlert This notification is sent when a resource
detects a new alert with severity minor. A
corresponding row will be created in the Alert
Table. The sequence number will increase for
ev… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.12 |
| eriAlarmMajorAlert This notification is sent when a resource
detects a new alert with severity major. A
corresponding row will be created in the Alert
Table. The sequence number will increase for
ev… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.13 |
| eriAlarmCriticalAlert This notification is sent when a resource
detects a new alert with severity critical. A
corresponding row will be created in the Alert
Table. The sequence number will increase for… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.14 |
| eriAlarmAppendAlertInfo This notification is sent in order to append
further info to an existing alert. It might be
additional text or a resource ID (OID)
identifying the alarming resource using an OID.
… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.15 |
| eriAlarmWarning This notification is sent when a resource
detects a new alarm state with severity warning.
The notification is also used to change severity
and/or additional text of an alarm. The… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.2 |
| eriAlarmHeartBeatNotif This is a heartbeat notification with interval
according to the eriAlarmHbInterval. It contains
the last sequence numbers used for alarms and
alarm events. These varbinds can be u… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.20 |
| eriAlarmMinor This notification is sent when a resource
detects a new alarm state with severity minor.
The notification is also used to change severity
and/or additional text of an alarm. The
c… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.3 |
| eriAlarmAlarmListRebuilt This notification is sent when the active alarm
list has reached a stable situation after a
restart or after a system internal audit process.
It is an indication to the manager to… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.30 |
| eriAlarmMajor This notification is sent when a resource
detects a new alarm state with severity major.
The notification is also used to change severity
and/or additional text of an alarm. The
c… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.4 |
| eriAlarmCritical This notification is sent when a resource
detects a new alarm state with severity critical.
The notification is also used to change severity
and/or additional text of an alarm. Th… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.5 |
| eriAlarmCleared This notification is sent when a resource
detects a cleared alarm state. The combination
of ManagedObject and MajorType/MinorType is
always unique and shall be used by management
… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.7 |
| eriAlarmAppendInfo This notification is sent in order to append
further info to an existing alarm. It might be
additional text or a resource ID (OID)
identifying the alarming resource using an OID.
… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.8 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eriAlarmActiveManagedObject The 3GPP naming convention shall be used as
format for the managed object parameter. Note
that the granularity must be good enough to
guarantee unique alarm states and relevant
re… | column | ERICSSON-TC-MIBEriMO | .1.3.6.1.4.1.193.183.4.1.3.5.1.5 |
| eriAlarmActiveMajorType In combination with eriAlarmActiveMinorType,
this provides a unique identification of the
fault type. Different managed object types and
instances can share alarm types, but if th… | column | ERICSSON-ALARM-TC-MIBEriAlarmType | .1.3.6.1.4.1.193.183.4.1.3.5.1.2 |
| eriAlarmActiveMinorType In combination with with
eriAlarmActiveMajorType, this provides a unique
identification of the fault type, not including
the managed object. Different managed object
types and ins… | column | ERICSSON-ALARM-TC-MIBEriAlarmType | .1.3.6.1.4.1.193.183.4.1.3.5.1.3 |
| eriAlarmActiveSpecificProblem This is a clear-text unique identification of
the alarm type. There is a one-to-one mapping
between eriAlarmActiveSpecificProblem and
[eriAlarmActiveMajorType,eriAlarmActiveMinorT… | column | ERICSSON-ALARM-TC-MIBEriAlarmSpecificProblem | .1.3.6.1.4.1.193.183.4.1.3.5.1.4 |
| eriAlarmActiveLastSequenceNo The last used sequence number for a alarm state
change notification. A management system can poll
this variable in order to detect lost alarm
change notifications. | scalar | ERICSSON-ALARM-TC-MIBEriAlarmSequenceNumber | .1.3.6.1.4.1.193.183.4.1.3.3 |
| eriAlarmActiveEventType The event type as defined in X.733/X.736. | column | IANA-ITU-ALARM-TC-MIBIANAItuEventType | .1.3.6.1.4.1.193.183.4.1.3.5.1.6 |
| eriAlarmActiveEventTime A time stamp of the alarm state change event.
Note that this variable represents the last
change of the alarm state, like changed severity
or additional text. If the alarm has not… | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.193.183.4.1.3.5.1.7 |
| eriAlarmActiveProbableCause The probable cause for the alarm originally
defined by X.733 and subsequent standards. See
also the ERICSSON-ALARM-PC-MIB. Due to the
history of problems in maintaining a standard… | column | ERICSSON-ALARM-PC-MIBEriProbableCause | .1.3.6.1.4.1.193.183.4.1.3.5.1.9 |
| eriAlarmNObjAdditionalText This is a scalar variable only used in
notifications. It is size ranged with a smaller
size than the corresponding type used in the
active alarm table. This is in order to make su… | scalar | ERICSSON-ALARM-TC-MIBEriAdditionalText | .1.3.6.1.4.1.193.183.4.1.2.1 |
| eriAlarmNObjMoreAdditionalText This is a scalar variable only used in
notifications. It tells the management system
that the additional text will be appended by
subsequent append additional text notifications.
… | scalar | SNMPv2-TCTruthValue | .1.3.6.1.4.1.193.183.4.1.2.2 |
| eriAlarmNObjResourceId This is a scalar variable only used in
notifications. It tells the management system
that there is an SNMP-based Resource ID (OID)
that identifies the alarming resource. NOTE:
th… | scalar | SNMPv2-TCTruthValue | .1.3.6.1.4.1.193.183.4.1.2.3 |