eriAlarmAppendInfo
ERICSSON-ALARM-MIB ·
.1.3.6.1.4.1.193.183.4.2.0.8
Object
notification
This notification is sent in order to append
further info to an existing alarm. It might be
additional text or a resource ID (OID)
identifying the alarming resource using an OID.
If additional text is sent, do not confuse this
with an actual change of additional text which is
reported using the eriAlarm<severity>
notification.
A zero-length string value for
eriAlarmNObjAdditionalText means that no
additional text is being sent in this
notification.
A null OID (0.0) value for
eriAlarmActiveResourceId means that no resource
ID is being sent in this notification.
Context
- MIB
- ERICSSON-ALARM-MIB
- OID
.1.3.6.1.4.1.193.183.4.2.0.8- Type
- notification
- Status
- current
- Parent
- eriAlarmNotifsPrefix
- Siblings
- 14
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eriAlarmIndeterminate This notification is sent when a resource
detects a new alarm state with severity
indeterminate. The notification is also used to
change severity and/or additional text of an
alar… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.1 |
| eriAlarmIndAlert This notification is sent when a resource
detects a new alert with severity indeterminate.
A corresponding row will be created in the Alert
Table. The sequence number will increas… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.10 |
| eriAlarmWarnAlert This notification is sent when a resource
detects a new alert with severity warning. A
corresponding row will be created in the Alert
Table. The sequence number will increase for
… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.11 |
| eriAlarmMinorAlert This notification is sent when a resource
detects a new alert with severity minor. A
corresponding row will be created in the Alert
Table. The sequence number will increase for
ev… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.12 |
| eriAlarmMajorAlert This notification is sent when a resource
detects a new alert with severity major. A
corresponding row will be created in the Alert
Table. The sequence number will increase for
ev… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.13 |
| eriAlarmCriticalAlert This notification is sent when a resource
detects a new alert with severity critical. A
corresponding row will be created in the Alert
Table. The sequence number will increase for… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.14 |
| eriAlarmAppendAlertInfo This notification is sent in order to append
further info to an existing alert. It might be
additional text or a resource ID (OID)
identifying the alarming resource using an OID.
… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.15 |
| eriAlarmWarning This notification is sent when a resource
detects a new alarm state with severity warning.
The notification is also used to change severity
and/or additional text of an alarm. The… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.2 |
| eriAlarmHeartBeatNotif This is a heartbeat notification with interval
according to the eriAlarmHbInterval. It contains
the last sequence numbers used for alarms and
alarm events. These varbinds can be u… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.20 |
| eriAlarmMinor This notification is sent when a resource
detects a new alarm state with severity minor.
The notification is also used to change severity
and/or additional text of an alarm. The
c… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.3 |
| eriAlarmAlarmListRebuilt This notification is sent when the active alarm
list has reached a stable situation after a
restart or after a system internal audit process.
It is an indication to the manager to… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.30 |
| eriAlarmMajor This notification is sent when a resource
detects a new alarm state with severity major.
The notification is also used to change severity
and/or additional text of an alarm. The
c… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.4 |
| eriAlarmCritical This notification is sent when a resource
detects a new alarm state with severity critical.
The notification is also used to change severity
and/or additional text of an alarm. Th… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.5 |
| eriAlarmCleared This notification is sent when a resource
detects a cleared alarm state. The combination
of ManagedObject and MajorType/MinorType is
always unique and shall be used by management
… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.7 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eriAlarmActiveManagedObject The 3GPP naming convention shall be used as
format for the managed object parameter. Note
that the granularity must be good enough to
guarantee unique alarm states and relevant
re… | column | ERICSSON-TC-MIBEriMO | .1.3.6.1.4.1.193.183.4.1.3.5.1.5 |
| eriAlarmActiveMajorType In combination with eriAlarmActiveMinorType,
this provides a unique identification of the
fault type. Different managed object types and
instances can share alarm types, but if th… | column | ERICSSON-ALARM-TC-MIBEriAlarmType | .1.3.6.1.4.1.193.183.4.1.3.5.1.2 |
| eriAlarmActiveMinorType In combination with with
eriAlarmActiveMajorType, this provides a unique
identification of the fault type, not including
the managed object. Different managed object
types and ins… | column | ERICSSON-ALARM-TC-MIBEriAlarmType | .1.3.6.1.4.1.193.183.4.1.3.5.1.3 |
| eriAlarmNObjAdditionalText This is a scalar variable only used in
notifications. It is size ranged with a smaller
size than the corresponding type used in the
active alarm table. This is in order to make su… | scalar | ERICSSON-ALARM-TC-MIBEriAdditionalText | .1.3.6.1.4.1.193.183.4.1.2.1 |
| eriAlarmActiveResourceId In case the alarm refers to an object which is
instrumented by SNMP this variable indicates the
corresponding OID for the managed object. | column | ALARM-MIBResourceId | .1.3.6.1.4.1.193.183.4.1.3.5.1.14 |