eriAlarmHeartBeatNotif
ERICSSON-ALARM-MIB ·
.1.3.6.1.4.1.193.183.4.2.0.20
Object
notification
This is a heartbeat notification with interval
according to the eriAlarmHbInterval. It contains
the last sequence numbers used for alarms and
alarm events. These varbinds can be used to
detect lost notifications.
The notification eriAlarmHeartBeatNotif will be
sent every eriAlarmHbInterval. Managers can
subscribe to the notification using the SNMP
framework MIBS by using the snmpNotifyName
'heartbeat'. (SNMP-NOTIFICATION-MIB,
snmpNotifyTable).
Context
- MIB
- ERICSSON-ALARM-MIB
- OID
.1.3.6.1.4.1.193.183.4.2.0.20- Type
- notification
- Status
- current
- Parent
- eriAlarmNotifsPrefix
- Siblings
- 14
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eriAlarmIndeterminate This notification is sent when a resource
detects a new alarm state with severity
indeterminate. The notification is also used to
change severity and/or additional text of an
alar… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.1 |
| eriAlarmIndAlert This notification is sent when a resource
detects a new alert with severity indeterminate.
A corresponding row will be created in the Alert
Table. The sequence number will increas… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.10 |
| eriAlarmWarnAlert This notification is sent when a resource
detects a new alert with severity warning. A
corresponding row will be created in the Alert
Table. The sequence number will increase for
… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.11 |
| eriAlarmMinorAlert This notification is sent when a resource
detects a new alert with severity minor. A
corresponding row will be created in the Alert
Table. The sequence number will increase for
ev… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.12 |
| eriAlarmMajorAlert This notification is sent when a resource
detects a new alert with severity major. A
corresponding row will be created in the Alert
Table. The sequence number will increase for
ev… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.13 |
| eriAlarmCriticalAlert This notification is sent when a resource
detects a new alert with severity critical. A
corresponding row will be created in the Alert
Table. The sequence number will increase for… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.14 |
| eriAlarmAppendAlertInfo This notification is sent in order to append
further info to an existing alert. It might be
additional text or a resource ID (OID)
identifying the alarming resource using an OID.
… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.15 |
| eriAlarmWarning This notification is sent when a resource
detects a new alarm state with severity warning.
The notification is also used to change severity
and/or additional text of an alarm. The… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.2 |
| eriAlarmMinor This notification is sent when a resource
detects a new alarm state with severity minor.
The notification is also used to change severity
and/or additional text of an alarm. The
c… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.3 |
| eriAlarmAlarmListRebuilt This notification is sent when the active alarm
list has reached a stable situation after a
restart or after a system internal audit process.
It is an indication to the manager to… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.30 |
| eriAlarmMajor This notification is sent when a resource
detects a new alarm state with severity major.
The notification is also used to change severity
and/or additional text of an alarm. The
c… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.4 |
| eriAlarmCritical This notification is sent when a resource
detects a new alarm state with severity critical.
The notification is also used to change severity
and/or additional text of an alarm. Th… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.5 |
| eriAlarmCleared This notification is sent when a resource
detects a cleared alarm state. The combination
of ManagedObject and MajorType/MinorType is
always unique and shall be used by management
… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.7 |
| eriAlarmAppendInfo This notification is sent in order to append
further info to an existing alarm. It might be
additional text or a resource ID (OID)
identifying the alarming resource using an OID.
… | notification | - | .1.3.6.1.4.1.193.183.4.2.0.8 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eriAlarmActiveLastSequenceNo The last used sequence number for a alarm state
change notification. A management system can poll
this variable in order to detect lost alarm
change notifications. | scalar | ERICSSON-ALARM-TC-MIBEriAlarmSequenceNumber | .1.3.6.1.4.1.193.183.4.1.3.3 |
| eriAlarmAlertLastSequenceNo The last sequence number used in alert
notifications. This can be used to detect a lost
notification. | scalar | ERICSSON-ALARM-TC-MIBEriAlarmSequenceNumber | .1.3.6.1.4.1.193.183.4.1.4.3 |
| eriAlarmActiveLastChanged A timestamp when the active alarm table was last
changed. The value can be used by a manager to
initiate an alarm resynchronization procedure.
NOTE: All fields of the DateAndTime … | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.193.183.4.1.3.2 |
| eriAlarmAlertLastChanged A timestamp when the alert table was last
changed. Can be used by a manager to initiate a
an update of alerts procedure.
NOTE: All fields of the DateAndTime MUST be